Sign In
Upload
Manuals
Brands
Roche Manuals
Measuring Instruments
9180
Roche 9180 Manuals
Manuals and User Guides for Roche 9180. We have
2
Roche 9180 manuals available for free PDF download: Service Manual, Instructions For Use Manual
Roche 9180 Instructions For Use Manual (186 pages)
Electrolyte Analyzer
Brand:
Roche
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
5
In this Chapter Chapter
1
Publication Information
2
Contact Addresses
4
Edition
4
Local Service Contact
4
In this Chapter Chapter
6
Preface
7
Intended Use
7
Intended User
7
Use Environment
7
Symbols and Abbreviations
7
In this Chapter Chapter
7
In this Chapter Chapter
8
In this Chapter Chapter
9
In this Chapter Chapter
10
In this Chapter Chapter
11
Safety Information 1
17
Safety Classifications
18
Operator Qualification
19
Safe and Proper Use of the System
19
Safety Precautions
19
Electrical Safety
20
Installation and Deinstallation
20
Operating Conditions
20
Biohazardous Materials
21
Consumables
22
Mechanical Safety
22
Reagents and Working Solutions
22
Incorrect Results
23
Software and Data Security
23
Instrument Damage
24
Consumables
25
Safety Labels on the Instrument and Consumables
25
General Description 2
27
Introduction
29
Calibration Procedure
30
Measurement and Calibration Procedures
30
Measurement Procedure
30
Measurement Evaluation
31
Standby Mode
32
Specifications 3
33
Material: ISETROL Protein Based Aqueous Control Material (Level 1), N=80
35
Measurement Parameters
35
Performance Parameters
35
Reproducibility
35
Material: Aqueous Standard Solution (Level 1), N=80
36
Material: ISETROL Protein Based Aqueous Control Material (Level 2), N=80
36
Material: ISETROL Protein Based Aqueous Control Material (Level 3), N=80
36
Material: RNA EQUIL Reduced Bovine Hemoglobin Solution (Level 2), N=80
36
Material: Aqueous Standard Solution (Level 2), N=80
37
Material: Pooled Human Serum, N=80
37
Material: Urine, N=80
37
Correlation to Flame
38
Linearity
38
Linearity in Aqueous Standard Solutions
38
Linearity in Serum
38
Correlation to Chloridometry
39
Correlation to Direct ISE - Flame-Correlated
39
Correlation to Direct ISE - Not Flame-Correlated
39
Interferences
40
Limitations
40
Bibliography
41
Relationship of Ionized Calcium to Total Calcium
41
Calibrations
43
Sample Throughput
43
Sample Types
43
Sample Volumes
43
Electrodes
44
Environmental Parameters
44
Instrument
44
Temperature / Humidity / Stability
44
Snappak
45
Solutions
45
Sodium Electrode Conditioner
46
Urine Diluent
46
Deproteinizer
47
Display
47
ISETROL Electrolyte Control
47
Printer
47
Product Data
47
QC Material
47
Classification (According to IEC/ISO)
48
Dimensions
48
Display
48
Electrical Data
48
Printer
48
Product Data
48
Theoretical Foundation 4
49
Reference / Normal Ranges
51
Reference and Critical Values
51
Critical Ranges
52
Measurement Principle
53
Principles of Operation
53
Physical Principle
54
Construction
57
Electrode Specifications
57
Sodium Electrode
57
Use and Care
57
Construction
58
Potassium Electrode
58
Use and Care
58
Chloride Electrode
59
Construction
59
Use and Care
59
Calcium Electrode
60
Construction
60
Use and Care
60
Construction
62
Lithium Electrode
62
Use and Care
62
Construction
63
Reference Electrode Assembly
63
Reference Electrode Housing
63
Use and Care
63
Reference Electrode
64
Use and Care
64
System Components 5
67
Analyzer Components
69
System Description
69
Display
70
Keypad
70
Measuring Chamber
71
Peristaltic Pump
71
Printer
71
Sample Probe Mechanism
72
Snappak
72
Valves
72
Name Plate
73
Rear Panel
73
Installation and Shutdown 6
77
Installation
79
Location
79
Accessories
80
Setting up
80
Electrode and Measuring Chamber
81
Preparing the Analyzer for Operation
86
Selecting Language
86
Start-Up
86
Installing the Snappak
87
Setting Date and Time
87
Installing the Printer Paper
88
Daily Maintenance (Manual)
89
Selecting Parameter Configuration
91
Installing Shutdown Plug
92
Shutdown
92
Installing the Transport Housing
93
Removing the Electrodes and the Shutdown Plug
94
Washing the Lines
94
Installing the Relief Clamps and Removing the Pump Windings
95
Turning the Analyzer "Off
96
Measurement 7
97
Preanalytics
99
Safety
99
Sample Collection
99
Sample Requirements
99
Acceptable Anticoagulants
100
Sample Collection Containers
100
Syringes
100
Capillary Tubes
101
Sample Handling
101
Whole Blood
101
Aqueous Solutions
102
Plasma
102
Serum
102
Interference
103
Plasma Samples
103
Substances Without Effect
103
Whole Blood Samples
104
Effect of the Substances (Plasma Samples)
105
Substances with Effect
105
Effect of the Substances (Whole Blood Samples)
106
Electrolytes
107
General
107
Limitations of Clinical Analysis
107
Measuring Procedure
108
Sample Measurement
108
Direct ISE
110
Urine Samples
111
Normal Ranges (Reference Values)
112
Correlation Factors
113
Additional Settings
115
Quality Control 8
117
General QC Concept
119
Quality Control
119
Material Setup
121
Performing a QC Measurement
123
Printing a QC Report
125
Maintenance 9
129
Disinfection
131
Maintenance
131
Recommended Disinfectants
132
Daily Maintenance
133
Clean Sample Probe and Fill Port
135
Weekly Maintenance
135
Cleaning Surfaces of the Analyzer
136
Cleaning the Reference Electrode Housing
137
Monthly Maintenance
137
Exchanging the Pump Tubing Set
140
Semi-Annual Maintenance
140
Annual Maintenance
141
Exchanging Main Tubing Harness
141
Unscheduled Maintenance
142
Replacing Electrodes
143
Checking Reagent Fluid Level and Changing the Snappak
145
Replacing Sample Probe and Fill Port
147
Replacing Printing Paper
148
Replacing the Mains Fuse
149
Troubleshooting 10
153
Error Messages
155
Troubleshooting
155
Service Functions
159
Testing the Electrodes
159
Potassium Electrode Not Calibrated
160
Testing the Sample Sensor
160
Testing the Snappak Sensor
160
Testing the Language Switch
161
Testing the Sample Door
161
Testing the Amplifier
162
Testing the Interface
162
Testing the Pump
162
Testing the Valves
162
Status Leds
163
Entering Service Codes
164
Removing Service Codes
164
Service Codes
164
List of Service Codes
165
Clearing All Data
166
Clearing Sample Count
166
Deleting Data
166
Appendix 11
169
Description of Reports
171
Measurement Report
171
QC Report
171
Calibration Report
172
Specifications of the Solutions
173
Program Flow Chart
174
Maintenance Schedule
175
Available Accessories and Consumables
176
Electrodes
176
QC Material
177
Solutions
177
Supplementary Equipment
178
Advertisement
Roche 9180 Service Manual (192 pages)
pH/Electrolyte Analyzers
Brand:
Roche
| Category:
Measuring Instruments
| Size: 9 MB
Table of Contents
System Description
15
Table of Contents
15
Safety Information
19
Important Information
19
Important Notes and Warnings
20
Operating Safety Information
20
Disinfectants
21
Deproteinizer
21
Other Disinfectants
21
ESD Protection Measures
22
Explanation of the Phenomenon
22
Influence of Electrostatic Charges on Components
22
Conclusion
23
Why Is ESD Protection so Important Today
23
How Can ESD Protection be Guaranteed
23
Specifications
25
Operating Parameters
27
Specifications
27
Common Operating Parameter
28
Approvals
29
Classifications
29
Product Data
29
Interface Specifications
31
Interface Information
33
Interface Specifications
33
Software
33
Automatic Calibration Report
34
Data Link Information (9180/9181 Only
34
Example Data String Information
34
Serum Sample Report
34
Description of Modules
35
Description of Modules
37
Front Door Assembly
37
Mechanical Assemblies
37
Needle Unit Assembly
37
Electrode Holder Assembly
38
Peristaltic Pump Assembly
38
Printer Assembly
39
Rear Panel Assembly
39
Solenoid Assembly
39
SBC Board
40
Display Board
41
Fluidic Module
41
Lamp Board
41
Standard a
41
Standard B
41
Standard C (Not on 9110
41
Cleaning Solution (9110 Only
42
Main Tube Set (All Models)/ Intake Tube Set (9110 Only
42
Reference Solution
42
Waste Liquids
42
Sample Contacts (9110 Only
43
Electronics
47
ISE SBC Card
47
Lamp Board
48
Display Board
49
Electronic Diagrams
51
Electronic Diagrams
52
9110 Analyzer Block Diagram
53
Electronic Diagrams
54
9181 Analyzer Block Diagram
55
System Interconnect - 9110, 9120, 9130, 9140
56
SBC PCB - Power Supply - 9110, 9120, 9130, 9140
57
SBC PCB - Valve Drivers - 9110, 9120, 9130, 9140
58
SBC PCB - Pump Motor Driver / Door Detect - 9110, 9120, 9130, 9140
59
SBC PCB - Input Amplifiers - 9110, 9120, 9130, 9140
60
SBC PCB - Temperature Circuit - 9110, 9120, 9130, 9140
61
SBC PCB - Analog Selector and A/D Converter - 9110, 9120, 9130, 9140
62
SBC PCB - Microprocessor - 9110, 9120, 9130, 9140
63
SBC PCB - Printer Display Drivers - 9110, 9120, 9130, 9140
64
Printer Daughter PCB - 9110, 9120, 9130, 9140, 9180, 9181
65
Lamp PCB - 9110, 9120, 9130, 9140
66
Display Daughter PCB - 9110
67
Preheater PCB - 9110
68
Display Daughter PCB - 9120, 9130, 9140
69
System Interconnect - 9180, 9181
70
SBC PCB - Power Supply - 9180, 9181
71
SBC PCB - Valve Drivers - 9180, 9181
72
SBC PCB - Pump Motor Driver/Door Detect - 9180, 9181
73
SBC PCB - Input Amplifier - 9180, 9181
74
SBC PCB - Temperature Circuit - 9180, 9181
75
SBC PCB - Analog Selector and A/D Converter - 9180, 9181
76
SBC PCB - Microprocessor - 9180, 9181
77
Software Operation
83
Main Menu
87
Measurement Sequence
87
Overall Program Operation Flow
87
Overview
87
Print Functions Menu
87
Software Operation 9110
87
QC Sample Menu
92
Daily Maintenance Menu
93
Operator Functions Menu
94
Program Instrument Menu
95
Service Functions Menu
96
Calibration Sequence
97
Software Operation 9120, 9130, 9140
101
Software Operation 9180
113
Overview
115
Software Operation 9180
115
Overall Program Operation Flow
116
Main Menu
117
Measurement Sequence
118
Print Functions Menu
119
Qc/Standard/Dialysate/Urine Sample Menu
120
Daily Maintenance Menu
121
Operator Functions Menu
122
Program Instrument Menu
123
Service Functions Menu
124
Calibration Sequence (1) (Example Na/K/Li Calibration
125
Calibration Sequence (2) (Example Na/K/Li Calibration
126
Power-Up
127
Software Operation 9181
129
Overview
131
Software Operation 9181
131
Overall Program Operting Flow
132
Main Menu
133
Manual Measurement Sequence
134
Automated Measurement Sequence
135
Print Functions Menu
136
Qc/Std/Dialysate/Urine Sample Menu
137
Daily Maintenance Menu
138
Operator Functions Menu
139
Program Instrument Menu
140
Service Functions Menu
141
Calibration Sequence (1) (Example Na/K/Li Calibration
142
Calibration Sequence (2) (Example Na/K/Li Calibration
143
Power-Up Sequence
144
Service Functions
145
Service Functions
147
Test Electrodes
147
TEST LANGUAGE SWITCH (9180 and 9181 Only
147
Test Sample Sensor
147
TEST Snappak SENSOR (9180 and 9181 Only
147
TEST AUTOSAMPLER (9181 Only
148
TEST PROBE (9181 Only
148
Test Pump
148
TEST SAMPLE DOOR (Except 9181
148
Test Amplifier
149
Test Interface
149
Test Pinch Valves
149
Enter Service Code
150
Deleting Data
152
Miscellaneous Functions
152
Warm-Up Bypass
152
Adjustments
155
Adjustments
157
Sample Contacts Adjustment (9110 Only
157
Sample Sensor Adjustment (9120/9130/9140/9180/9181 Only
157
Temperature Adjustment (9110/9140/9180/9181 Only
158
Maintenance
159
Annual Preventive Maintenance
161
Daily Maintenance
161
Maintenance
161
Monthly Maintenance
161
Six Month Maintenance
161
Weekly Maintenance
161
Troubleshooting
165
Error Messages and Troubleshooting
167
Standard a Not Detected
167
Status-Leds
167
Status: Not Calibrated
167
Check Sample Contacts(9110), Check Sample Sensor (9120/30/40/80
168
STANDARD B NOT DETECTED, STANDARD C NOT DETECTED (9180/9181 Only
168
Check Reference Housing
169
PLEASE CLOSE SAMPLE DOOR (Except 9181
169
Cleaning Fluid Not Detected
170
CONDITIONING FLUID NOT DETECTED (Except 9110
170
No Sample
170
Check Electrodes
171
Interface Error
171
Not Cal'D
171
Paper Jam or Printer Defect
171
(Out of Range
173
(Temparature out of Range
173
CLOG in SAMPLE PATH (9110 Only), CLOG CHECK FLUID PATH (Except 9110
173
CHECK TEMPERATURE (9140/9180/9181 Only
174
Err
174
PERFORM DAILY MAINTENANCE (Except 9110
174
Replace Fluid Pack
174
Error: Lower Needle Sensor
175
Error: Upper Needle Sensor
175
Valve Overtemp! Check Valves
175
Software
191
Service Manual
192
Version 1.0
192
Version 2.0
192
Advertisement
Related Products
Roche 91 Series
Roche 9110
Roche 9120
Roche 9130
Roche 9140
Roche 9181
Roche Accutrend Plus
Roche Cedex Bio
Roche Cedex Bio HT
Roche Cedex HiRes
Roche Categories
Blood Glucose Meter
Medical Equipment
Measuring Instruments
Motorized Toy Car
Personal Care Products
More Roche Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL