Sign In
Upload
Manuals
Brands
RKI Instruments Manuals
Docking Station
SDM-2012
RKI Instruments SDM-2012 Manuals
Manuals and User Guides for RKI Instruments SDM-2012. We have
3
RKI Instruments SDM-2012 manuals available for free PDF download: Operator's Manual
RKI Instruments SDM-2012 Operator's Manual (218 pages)
PC Controlled Configuration
Brand:
RKI Instruments
| Category:
Docking Station
| Size: 5 MB
Table of Contents
Table of Contents
3
Introduction
6
System Requirements
7
Specifications
8
About this Manual
9
Cautions & Safety Information
9
Description
10
AC Adapter
10
Single-Port AC Adapter
10
3-Port AC Adapter
10
USB Cable
11
Air Filter, Sample Tubing, and Check Valve
11
Instrument Panel
13
Back Panel
15
Power Jack
15
Sample Fittings
15
PC Connection
15
Control Panel
16
Front Panel
17
USB Hub Requirements for Multiple Station Systems
17
Hardware Setup
18
Hardware Assembly
18
Assembling a Manifold for Multiple SDM-2012 Units
20
Exhaust Tubing
20
GAS 1 and GAS 2 Tubing
22
Connecting Calibration Gas
27
EAGLE 2 and GX Type Instrument Connection
28
Installing the SDM-GX Docking Station PC Controller Program
29
Launching the SDM-GX Docking Station PC Controller Program
34
Overview of the SDM-GX Docking Station PC Controller Program
35
PC Controller Program Functions
35
Main Program Window
36
Control Buttons
36
SDM-2012/Instrument Display Area
36
Program Status
37
Fitting Indicators
37
Setting up the PC Controller Program
37
Setting up the Configuration
37
Setting up the SDM-2012 Display Order
43
Cylinders Window
45
Selecting a Cylinder from the Predefined List
45
Defining New Cylinders
47
Connecting Instruments to the PC Controller Program
48
Icon View Vs. Details View
54
Exporting an Instrument List from the Main Program Window
55
Automatic Bump Testing and Calibration
56
Bump Testing a GX-2012
57
Calibrating a GX-2012
70
Bump Testing a Gas Tracer
82
Calibrating a Gas Tracer
100
Troubleshooting
117
Charging an Instrument in an SDM-2012
118
Recharging a Battery Pack after Performing a Bump Test or Calibration
118
Recharging a Battery Pack Without Performing any Operations
120
Battery Pack too Drained for PC Controller Operation
121
Logs Button
121
Alarm Trend Data
125
Calibration Data
130
Event Data
133
Interval Trend Data
135
Memo Data
140
Bump Test Data
143
Barhole Data
146
Normal Operation Snap Log Data
149
Leak Check Mode Snap Log Data
153
Deleting Data in the Logs Window
158
Instrument Function Menu
159
Open Function
159
Edit Function
160
Parameter Tab
160
Sensor Tab
170
Station & User Tab
172
Download Function
177
Clear Logs Function
177
Power off Function
177
Config Window
178
Parameter Tab
178
Database Tab
178
Password Tab
180
Spare Parts List
181
Appendix A: Multiple Instrument Configurations
183
Bump Testing GX-2012S and Gas Tracers
183
Calibrating GX-2012S and Gas Tracers
202
Advertisement
RKI Instruments SDM-2012 Operator's Manual (120 pages)
Brand:
RKI Instruments
| Category:
Docking Station
| Size: 1 MB
Table of Contents
Table of Contents
3
Chapter 1: Introduction
6
Overview
6
About the SDM-2012
6
System Requirements
7
Specifications
8
About this Manual
9
Cautions & Safety Information
9
Chapter 2: Description
10
Overview
10
AC Adapter
10
Single-Port AC Adapter
10
3-Port AC Adapter
10
USB Cable
11
Air Filter and Sample Tubing
11
Instrument Panel
13
Back Panel
15
Power Jack
15
Sample Fittings
15
PC Connection
15
Control Panel
16
Front Panel
18
Chapter 3: Preparing to Use the SDM-2012
19
Overview
19
Hardware Assembly
19
Assembling a Manifold for Multiple SDM-2012S
21
Setting the Operational Parameters in Edit Mode
28
Bump Test & Calibration Parameters
28
Turning on the SDM-2012 with an Instrument
30
Setting the Bump Test Parameters
33
Setting the Calibration Parameters
36
Setting the Gas Inlet for H 2 S (GX-2012 Only)
39
Updating the Tested Sensors Parameter
41
Connecting Calibration Gas
45
Installing the Single Module Data Viewer Software
47
Chapter 4: Operation
48
Overview
48
Bump Testing a GX-2012
48
Calibrating a GX-2012
61
Bump Testing a Gas Tracer
70
Calibrating a Gas Tracer
88
Troubleshooting
101
Charging an Instrument in a Docking Station
103
Recharging a Battery Pack after Performing a Bump Test or Calibration
103
Recharging a Battery Pack Without Performing any Operations
104
Battery Pack too Drained for Standalone Operation
105
Calibration and Bump Test Records
105
Available Memory in the SDM-2012
105
Copying Calibration and Bump Test Records
105
Clearing the SDM-2012'S Memory
107
Bump Test and Calibration Record Files
107
Bump Testing or Calibrating and Saving Files to a Flash Drive
107
Multiple Times in One Day
107
Chapter 5: Single Module Data Viewer Program
108
Overview
108
Launching the Single Module Data Viewer Program
108
Data Viewing Window
109
Using the Single Module Data Viewer Program
109
Importing Files into the Database
110
Organizing the Data
111
Viewing the Data
112
Deleting Data
116
Changing the Password
117
Exiting the Program
118
Chapter 6: Spare Parts List
119
RKI Instruments SDM-2012 Operator's Manual (112 pages)
Standalone Configuration
Brand:
RKI Instruments
| Category:
Docking Station
| Size: 1 MB
Table of Contents
Table of Contents
3
Chapter 1: Introduction
6
Overview
6
About the SDM-2012
6
System Requirements
7
Specifications
8
About this Manual
9
Cautions & Safety Information
9
Chapter 2: Description
10
Overview
10
AC Adapter
10
Single-Port AC Adapter
10
3-Port AC Adapter
10
USB Cable
11
Air Filter and Sample Tubing
11
Instrument Panel
13
Back Panel
15
Power Jack
15
Sample Fittings
15
PC Connection
15
Control Panel
16
Front Panel
18
Chapter 3: Preparing to Use the SDM-2012
19
Overview
19
Hardware Assembly
19
Setting the Operational Parameters in Edit Mode
21
Bump Test & Calibration Parameters
21
Turning on the SDM-2012 with an Instrument
23
Setting the Bump Test Parameters
26
Setting the Calibration Parameters
28
Setting the Gas Inlet for H 2 S (GX-2012 Only)
31
Updating the Tested Sensors Parameter
33
Connecting Calibration Gas
37
Installing the Single Module Data Viewer Software
39
Chapter 4: Operation
40
Overview
40
Bump Testing a GX-2012
40
Calibrating a GX-2012
53
Bump Testing a Gas Tracer
62
Calibrating a Gas Tracer
80
Troubleshooting
93
Charging an Instrument in a Docking Station
95
Recharging a Battery Pack after Performing a Bump Test
95
Or Calibration
95
Recharging a Battery Pack Without Performing any Operations
96
Battery Pack too Drained for Standalone Operation
96
Calibration and Bump Test Records
97
Available Memory in the SDM-2012
97
Copying Calibration and Bump Test Records
97
Clearing the SDM-2012'S Memory
99
Bump Test and Calibration Record Files
99
Bump Testing or Calibrating and Saving Files to a Flash Drive
99
Multiple Times in One Day
99
Chapter 5: Single Module Data Viewer Program
100
Overview
100
Launching the Single Module Data Viewer Program
100
Data Viewing Window
101
Using the Single Module Data Viewer Program
101
Importing Files into the Database
102
Organizing the Data
103
Viewing the Data
104
Deleting Data
108
Changing the Password
109
Exiting the Program
110
Spare Parts List
110
Advertisement
Advertisement
Related Products
RKI Instruments SDM-6000
RKI Instruments SDM-2009
RKI Instruments SDM-3R
RKI Instruments SDM-03
RKI Instruments SD-1GH
RKI Instruments SC-01
RKI Instruments SP-220 TYPE F
RKI Instruments SC-04
RKI Instruments SM-2009U
RKI Instruments S2 Series
RKI Instruments Categories
Transmitter
Security Sensors
Gas Detectors
Measuring Instruments
Monitor
More RKI Instruments Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL