Sign In
Upload
Manuals
Brands
RKI Manuals
Measuring Instruments
Gas Tracer
RKI Gas Tracer Portable Monitor Manuals
Manuals and User Guides for RKI Gas Tracer Portable Monitor. We have
1
RKI Gas Tracer Portable Monitor manual available for free PDF download: Operating Manual
RKI Gas Tracer Operating Manual (202 pages)
Brand:
RKI
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
4
Chapter 1: Introduction
8
Overview
8
About the Gas Tracer
8
Specifications
10
About this Manual
11
Chapter 2: Description
12
Overview
12
Instrument Description
12
Case
13
Sensors
13
Lcd
16
Control Buttons
16
Printed Circuit Boards
16
Alarm LED Arrays
16
Infrared Communications Port
17
Buzzer
17
Vibrator
17
Batteries
17
Pump
18
Flow Chamber
18
Sensors and Filters
18
Inlet Filter Holder
18
Standard Accessories
19
Tapered Rubber Nozzle
19
Belt Clip
19
Wrist Strap
19
Sample Hose & 10 Inch Probe
19
Optional Accessories
20
Charging Stations
20
Optional Probes
21
Purge Tee Fitting
23
External Dilution Fitting
24
Humidifier Tube
24
Chapter 3: Using the Gas Tracer in Normal Mode
25
Overview
25
Start Up, Normal Mode
25
Turning on the Gas Tracer, Normal Mode Only
25
Turning on the Gas Tracer in Normal with All Modes Active
30
Performing a Fresh Air Adjustment, Normal Mode
32
Turning off the Gas Tracer, Normal Mode
32
Measuring Mode, Normal Operation
33
Monitoring an Area
33
Using Optional Probes and Fittings
33
Combustible Gas Detection
35
CO with H 2 S Response Configuration
37
Snap Log Mode, Normal Operation
38
Measuring Mode, Alarms
41
Alarm Indications
41
Resetting and Silencing Alarms
43
Responding to Alarms
44
Inert Mode
46
Alarms
46
Start up and Operation
46
Display Mode
47
HC Range Screen
48
Peak Screen
48
STEL Screen
49
TWA Screen
49
Alarm Points Screen
49
Operation Time Screen
51
Date/Time Screen
51
Remaining Log Time Screen
52
Clear Data Logger Screens
53
Pump off Screen
54
User ID Screen
55
Station ID Screen
56
Snap Logging Screen
57
Peak Bar Select Screen
60
Datalogging
61
Sdm-2012
61
Calibration Mode
62
Calibration/Bump Test Supplies and Equipment
62
Preparing for Calibration or Bump Test
63
Calibrating the Gas Tracer
64
Bump Testing the Gas Tracer
70
Calibrating and Bump Testing the PPM Combustible Sensor
76
Chapter 4: Using the Gas Tracer in Bar Hole Mode
87
Overview
87
Start Up, Bar Hole Mode
87
Turning on the Gas Tracer, Bar Hole Mode
87
Performing a Fresh Air Adjustment, Bar Hole Mode
92
Bar Hole Testing
93
Performing a Bar Hole Test
93
Turning off the Gas Tracer, Bar Hole Mode
95
Chapter 5: Using the Gas Tracer in Leak Check Mode
96
Overview
96
Start Up, Leak Check Mode
96
Turning on the Gas Tracer, Leak Check Mode
96
Performing a Fresh Air Adjustment, Leak Check Mode
102
Leak Testing
103
Setting the Display Range Value
103
Locating a Leak
103
Overscale Conditions
104
Turning the Alarm on and off in Leak Check Mode
104
Peak Hold Mode
105
Snap Log Mode, Leak Check Mode Operation
106
Viewing Snap Log Data in Leak Check Mode Operation
108
Turning off the Gas Tracer, Leak Check Mode
110
Chapter 6: Maintenance Mode
111
Overview
111
Tips for Using Maintenance Mode
112
Using Maintenance Mode
112
Updating the Date and Time Settings
113
Performing a Fresh Air Adjustment
114
Calibrating Using Auto Calibration
115
Calibration Using Single Calibration
118
Performing a Bump Test
120
Calibrating and Bump Testing the PPM Combustible Sensor
125
Turning the Lunch Break Setting on or off
136
Updating the Alarm Latching Settings
137
Updating the Alarm Silence Settings
137
Updating the Data Logging Interval
138
Updating the Alarm Point Settings
139
Turning the Clear Data Logger Screen on or off
142
Turning the Bump Test Function on or off
143
Turning the Pump off Screen on or off
144
Updating the Bump Test Parameters
145
Updating the Confirmation Beep Setting
146
Updating the Datalog Overwrite Setting
147
Updating the Calibration Interval
147
Updating the Calibration Reminder Setting
148
Updating the Calibration Expired Action Setting
148
Updating the Calibration Check Setting
149
Updating the Bump Test Interval
149
Updating the Bump Test Reminder Setting
150
Updating the Bump Test Expired Action Setting
150
Updating the Bump Test Check Setting
151
Turning the ID Display Function on or off
152
Updating the LCD Backlight Time Setting
152
Updating the Autozero Function
153
Updating the Demand Zero Function
153
Updating the Leak Check/Bar Hole Mode Setting
154
Updating the Bar Hole Sampling Time
155
Updating the Leak Check Mode CO Display Setting
155
Viewing the ROM/SUM Information
156
Turning the Password Function on or off
156
Performing a Low Flow Setpoint Adjustment
158
Exiting Maintenance Mode
158
Chapter 7: Maintenance
159
Overview
159
Troubleshooting
159
Replacing or Recharging the Batteries
162
Replacing Alkaline Batteries
162
Replacing the Lithium Ion Battery Pack
163
Recharging the Lithium Ion Battery Pack in the Instrument
164
Recharging the Lithium Ion Battery Pack out of the Instrument
167
Replacing the LEL and CO Filters
169
Replacing a Sensor
170
Replacing the Hydrophobic Disk Filter, Cotton Filter
172
And Wire Mesh Disk
172
Parts List
173
Appendix A: Calibrating with a Sample Bag
176
Overview
176
Calibration Supplies & Equipment
176
Preparing for Calibration or Bump Test
177
Normal Operation Fresh Air Adjustment
177
Filling the Gas Bag
178
Calibrating the Gas Tracer
179
Calibrating with the Auto Calibration Method
180
Calibrating with the Single Calibration Method
182
Bump Testing
185
Calibrating and Bump Testing the PPM Combustible Sensor
191
Performing a Fresh Air Adjustment
192
Performing an Auto Calibration
193
Performing a Single Calibration
195
Performing a Bump Test
197
Parts List
202
Advertisement
Advertisement
Related Products
RKI Categories
Security Sensors
Transmitter
Gas Detectors
Controller
Carbon Monoxide Alarm
More RKI Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL