Sign In
Upload
Manuals
Brands
Rigol Manuals
Portable Generator
DSG5000 Series
Rigol DSG5000 Series RF Signal Generators Manuals
Manuals and User Guides for Rigol DSG5000 Series RF Signal Generators. We have
2
Rigol DSG5000 Series RF Signal Generators manuals available for free PDF download: Programming Manual, User Manual
Rigol DSG5000 Series Programming Manual (144 pages)
Microwave Signal Generator
Brand:
Rigol
| Category:
Portable Generator
| Size: 2 MB
Table of Contents
Table of Contents
3
Document Overview
9
SCPI Command Overview
11
Command System
14
Source Commands
14
Source][:Rf]:Frequency Commands
14
[:Source][:Rf]:Frequency
14
[:Source][:Rf]:Frequency:offset
15
Source][:Rf]:Level Commands
16
[:Source][:Rf]:Level
16
[:Source][:Rf]:Level:limit
17
[:Source][:Rf]:Level:offset
18
Source][:Rf]:Phase Commands
19
[:Source][:Rf]:Phase
19
[:Source][:Rf]:Phase:reset
20
Source][:Rf]:Correction Commands
21
Source][:Rf]:Correction:flatness[:State]
21
Source][:Rf]:Correction:flatness:count
21
[:Source][:Rf]:Correction:flatness:list
22
[:Source][:Rf]:Correction:flatness:delete
23
[:Source][:Rf]:Correction:flatness:pair
24
[:Source][:Rf]:Correction:flatness:load
24
Source][:Rf]:Correction:flatness:save
25
Source][:Rf]:Sweep Commands
26
[:Source][:Rf]:Sweep:direction
26
[:Source][:Rf]:Sweep:execute
26
[:Source][:Rf]:Sweep:list:addlist
27
[:Source][:Rf]:Sweep:list:cpoint
28
[:Source][:Rf]:Sweep:list:delete
29
[:Source][:Rf]:Sweep:list:list
29
Source][:Rf]:Sweep:list:initialize:fstep
30
[:Source][:Rf]:Sweep:list:initialize:preset
31
Source][:Rf]:Sweep:list:load
32
Source][:Rf]:Sweep:list:save
32
[:Source][:Rf]:Sweep:state
33
[:Source][:Rf]:Sweep:type
34
[:Source][:Rf]:Sweep:mode
34
[:Source][:Rf]:Sweep:reset[:All]
35
[:Source][:Rf]:Sweep:point:trigger:type
36
[:Source][:Rf]:Sweep:sweep:trigger:type
37
[:Source][:Rf]:Sweep:step:dwell
39
[:Source][:Rf]:Sweep:step:points
39
Source][:Rf]:Sweep:step:start:frequency
40
[:Source][:Rf]:Sweep:step:start:level
41
[:Source][:Rf]:Sweep:step:stop:frequency
42
[:Source][:Rf]:Sweep:step:stop:level
43
[:Source][:Rf]:Sweep:step:shape
44
[:Source][:Rf]:Sweep:step:spacing
45
Source][:Rf]:Am Commands
46
[:Source][:Rf]:Am:depth
46
[:Source][:Rf]:Am:frequency
46
[:Source][:Rf]:Am:waveform
47
[:Source][:Rf]:Am:state
48
[:Source][:Rf]:Am:source
49
[:Source][:Rf]:Am:equal:level
50
[:Source]:Am:ext:coup
50
[:Source]:Am:ext:imp
51
Source][:Rf]:Fm
52
Commands
52
[:Source][:Rf]:Fm:deviation
52
[:Source][:Rf]:Fm:frequency
53
[:Source][:Rf]:Fm:waveform
54
[:Source][:Rf]:Fm:state
54
[:Source][:Rf]:Fm:source
55
[:Source]:Fm:ext:coup
56
[:Source]:Fm:ext:imp
57
Source][:Rf]:Pm
58
Commands
58
[:Source][Rf]:Pm:deviation
58
[:Source][:Rf]:Pm:frequency
58
[:Source][:Rf]:Pm:waveform
59
[:Source][:Rf]:Pm:state
60
[:Source][:Rf]:Pm:source
61
[:Source]:Pm:ext:coup
62
[:Source]:Pm:ext:imp
62
Source][:Rf]:Pulm Commands
63
[:Source][:Rf]:Pulm:mode
63
[:Source][:Rf]:Pulm:out:state
64
[:Source][:Rf]:Pulm:period
65
[:Source][:Rf]:Pulm:polarity
66
[:Source][:Rf]:Pulm:source
66
[:Source][:Rf]:Pulm:state
67
Source][:Rf]:Pulm:train:list:count
68
[:Source][:Rf]:Pulm:train:list:insert
69
[:Source][:Rf]:Pulm:train:list:delete
69
[:Source][:Rf]:Pulm:train:list:get
70
[:Source][:Rf]:Pulm:train:list:run
71
[:Source][:Rf]:Pulm:train:list:load
71
Source][:Rf]:Pulm:train:list:save
72
[:Source][:Rf]:Pulm:trigger:delay
73
[:Source][:Rf]:Pulm:trigger:external:gate:polarity
73
[:Source][:Rf]:Pulm:trigger:external:slope
74
[:Source][:Rf]:Pulm:trigger:mode
75
[:Source][:Rf]:Pulm:width
77
Source][:Rf]:Output Commands
78
Source][:Rf]:Output[:State]
78
Source]:Rfall:output[:State]
78
Source][:Rf]:Modulation Commands
79
Source][:Rf]:Modulation:state
79
[:Source]:Rfall:modulation:state
80
Source:roscillator:hclock Commands
80
Source:roscillator:hclock:output:state
80
Source:roscillator:hclock:type
81
[:Source][:Rf]:Input:trigger:slope
82
Trigger Commands
82
Trigger[:Rf]:Pulm[:Immediate]
83
Trigger:rfall:pulm[:Immediate]
83
Trigger[:Rf][:Sweep][:Immediate]
84
Trigger:rfall[:Sweep][:Immediate]
84
Trigger[:Rf]:Pulm:key
85
Trigger:rfall:pulm:key
85
Trigger[:Rf][:Sweep]:Key
86
Trigger:rfall[:Sweep]:Key
86
UNIT Command
87
Unit[:Rf]:Power
87
System Commands
87
System:communication:lan:dhcp
88
System:communication:lan:ip:address
88
System:communication:lan:ip:auto
89
System:communication:lan:ip:gateway
90
System:communication:lan:ip:manual
91
System:communication:lan:ip:set
92
System:communication:lan:ip:subnet:mask
92
System:communication:lan:reset
93
System:communication:lan[:Self]:Preferred
93
System:communication:lan:mdns
94
System:communication:lan:host:name
95
System:communication:lan:mac
95
System:preset
96
System:preset:type
96
System:preset:save
97
System:fswitch:state
97
System:language
98
System:date
99
System:time
100
System:stime
100
System:clear
101
System:display:update[:State]
102
System:lkey
102
System:lkey:delete
103
System:option:list
104
System:configure:information
104
Mmemory Commands
105
Mmemory:catalog
105
Mmemory:catalog:length
105
Mmemory:copy
106
Mmemory:delete
107
Mmemory:disk:format
108
Mmemory:disk:information
108
Mmemory:filetype
109
Mmemory:channel:select
109
Mmemory:ldisk:space
110
Mmemory:load
111
Mmemory:mdirectory
111
Mmemory:move
112
Mmemory:pname:edit
113
Mmemory:pname:state
113
Mmemory:save
114
IEEE488.2 Common Commands
115
Cls
115
Ese
115
Idn
116
Psc
117
Rst
117
Sre
118
Stb
118
Trg
119
Wai
119
Status Commands
120
Status:operation:enable
121
Status:operation[:Event]
121
Application Examples
123
To Output the RF Signal
123
To Output the RF Sweep Signal
123
Programming Examples
125
Programming Preparations
125
Excel Programming Examples
126
Matlab Programming Example
130
Labview Programming Example
131
Visual C++ Programming Example
136
Appendix
141
Appendix A: Factory Setting
141
Appendix B: Warranty
143
Advertisement
Rigol DSG5000 Series User Manual (84 pages)
Microwave Signal Generator
Brand:
Rigol
| Category:
Laboratory Equipment
| Size: 5 MB
Table of Contents
Table of Contents
3
Safety Requirement
7
General Safety Summary
7
Safety Notices and Symbols
8
Measurement Category
9
Care and Cleaning
10
Environmental Considerations
10
DSG5000 Series Overview
11
Document Overview
12
Quick Start
14
General Inspection
14
Appearance and Dimensions
14
Figure 4.1 Front View (Unit: MM)
14
Front Panel Overview
15
Figure 4.2 Vertical View (Unit: MM)
15
Figure 4.3 DSG5208 Front Panel
15
Rear Panel Overview
18
Figure 4.4 DSG5208 Rear Panel
18
To Use DSG5000 for the First Time
19
To Connect to AC Power
19
Instrument Control
20
Figure 4.5 to Connect to AC Power
20
Turn-On Checkout
21
To Set the System Language
21
Fuse Replacement
21
User Interface
22
Figure 4.6 Fuse Replacement
22
Figure 4.7 User Interface
22
To Use the Built-In Help File
25
Keypad Setting
26
Numeric Keypad for Setting Parameter Values
26
Figure 5.1 Numeric Keypad
26
Alphanumeric Keypad for Filename Input
28
Figure 5.2 Chinese Character Input
29
Figure 5.3 English Letter Input
31
Figure 5.4 Number Input Keypad
33
Frequency
34
Frequency Setting
34
Freq Offset
34
Phase Offset
35
Phase Reset
35
Amplitude
36
Amplitude Setting
36
Amplitude Limit
36
Amplitude Offset
36
Flatness Calibration
37
Amplitude Unit
38
Sweep
39
Sweep Function
39
Sweep Type
39
Step Sweep
39
List Sweep
42
Figure 8.1 Diagram of the Sweep Shape in "Fwd" Sweep Direction
42
Sweep Mode
43
Trigger
44
Modulation
47
Amplitude Modulation (AM)
47
To Enable the Amplitude Modulation
47
To Select the Modulation Source
47
To Set the Modulation Depth
47
To Set the Modulation Frequency
48
To Set Other AM-Related Parameters
48
Frequency Modulation (FM)
50
To Enable the Frequency Modulation
50
To Select the Modulation Source
50
Figure 9.1 Diagram of Equal Level Output
50
To Set the Frequency Deviation
51
To Set the Modulation Frequency
51
To Set Other FM-Related Parameters
52
Phase Modulation (PM)
52
To Enable the Phase Modulation
52
To Select Modulation Source
53
To Set the Phase Deviation
53
To Set the Modulating Rate
54
To Set Other PM-Related Parameters
54
Pulse Modulation
55
To Enable the Pulse Modulation
55
To Select Modulation Source
55
To Set the Pulse Type
55
To Set Other Pulse-Related Parameters
56
Trigger
58
Figure 9.2 Trigger Delay
59
System Utility Setting
61
Interface Setting
61
Lan
61
Figure 10.1 System Utility Setting
61
Preset
63
Aux
63
4.8 Ghz Signal Input/Output
63
Upgrade
64
Local Upgrade
64
Figure 10.2 File Resource Management System
65
Online Upgrade
66
System
66
Storage
67
Disk Management
68
Help Menu
69
Setting
69
Basic Settings
69
Self Check
70
Remote Control
72
Remote Control Via USB
73
Remote Control Via LAN
73
Application Examples
75
To Output the RF Signal
75
To Output the RF Sweep Signal
76
To Output the RF Modulated Signal
77
Troubleshooting
79
Appendix
82
Appendix A: Accessories and Option List
82
Appendix B Warranty
83
Advertisement
Related Products
Rigol DSG800 Series
Rigol DSG3000B Series
Rigol DSG3065B
Rigol DSG3065B-IQ
Rigol DSG3136B
Rigol DSG3136B-IQ
Rigol DSG821
Rigol DSG821A
Rigol DSG830
Rigol DSG836
Rigol Categories
Test Equipment
Measuring Instruments
Portable Generator
Power Supply
Inverter
More Rigol Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL