Rigaku MiniFlex 600 Manuals
Manuals and User Guides for Rigaku MiniFlex 600. We have
1
Rigaku MiniFlex 600 manual available for free PDF download: Instruction Manual
Rigaku MiniFlex 600 Instruction Manual (111 pages)
Benchtop X-ray Diffractometer
Brand:
Rigaku
| Category:
Measuring Instruments
| Size: 8 MB
Table of Contents
Table of Contents
3
Overview
7
Overview of Miniflex 600
7
Optical System Using SC
8
Configuration
9
Standard Configuration
9
Names of Parts
10
List of Shipped Items
14
Specifications
15
X-Ray Generator
15
Tube Shield
15
Goniometer (Angle Measuring Device)
15
Detector (SC)
16
Counting Control Circuit (ECP)
16
Radiation Enclosure
16
Cooling-Water Unit
16
X-Ray Tube
17
Computer (Reference Specifications)
17
Standard Software
17
Optional Accessories
18
D/Tex Ultra High-Speed 1D Detector (Optional)
18
Installation Condition
19
Installation Room
19
Environmental Conditions of Installation Room
19
Preparing Power Supply
20
Cooling Water
21
Drainage
21
Others
21
Installation of Miniflex600
23
Unpacking
23
Installing the X-Ray Tube
23
Connecting the Cooling Water Hose
24
Installing the Scintillation Counter (SC)
25
Installing the D/Tex Ultra (Optional)
28
Installing the Beam Stop
30
Installing and Retracting the Variable Knife Edge
30
Installing the Variable Knife Edge
30
Retracting the Slider
32
Installing the DS and IHS (Length Limiting)
33
Connecting the Power Cable
33
Connecting with Computer
33
Installing the Software
34
Setting and Adjustment
35
Types of Soller Slit, Confirming the Soller Slit
35
Types of Incident Soller Slit
35
Confirming the Incident Soller Slit
35
Types of Receiving Soller Slit
36
Optics Alignment (Required for Periodic Inspection or Installing X-Ray Tube)
37
Optics Alignment (for SC)
37
Optics Alignment (D/Tex Ultra)
48
Optics Alignment (for D/Tex Only)
56
HV/PHA Adjustment of Scintillation Counter (SC)
70
Discriminator Value Setting by D/Tex Ultra
73
Automatic Adjustment of Discriminator Value
73
Directly Entering the D/Tex Ultra Adjustment Value
75
Initial Setting of the Measurement Environment (Required When the X-Ray Tube Type Has Been Changed)
77
Data Measurement and Setting Procedure for Real-Time 2 Theta Axis Correction (Required for Initial Setup or Periodic Inspection)
78
Startup and Shutdown (Daily Routine)
83
Starting up the System
83
Shutting down the System
84
Measurement of Samples (Daily Routine)
85
Preparing the Sample Plate
85
Preparation of Powder Sample on Aluminum Sample Plate
85
Preparation of Block Sample on Aluminum Sample Plate
87
Preparation of Powder Sample on Glass Sample Plate
87
Cleaning Spilled or Deposited Powder Sample
88
Slit System
89
Slit Correction
89
Measurement with Miniflex Guidance
91
Maintenance
97
X-Ray Tube and Scintillation Counter (SC)
97
Replacing the X-Ray Tube (Procedures Required When Cleaning Filter or Replacing Tube)
97
Removing and Installing the X-Ray Tube
97
Disassembling the X-Ray Tube and Cleaning the Filter
99
Cleaning and Further Information
100
Confirming the Alarm Information
101
Installing the Optional Sample Attachment
103
Installing the Counter Monochromator (Optional)
105
Installing the Counter Monochromator
106
Optics Alignment and Notes on Monochromator
109
Arrangement of Slits
110
Advertisement
Advertisement
Related Products
Rigaku 4364F501
Rigaku KT-100
Rigaku Progeny
Rigaku Progeny LT
Rigaku R-XAS
Rigaku Smartlab SE
Rigaku XtaLAB mini
Rigaku Categories
Measuring Instruments
Laboratory Equipment
Security Sensors
Industrial Equipment
Monitor
More Rigaku Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL