Sign In
Upload
Manuals
Brands
Richardson RFPD Manuals
Control Unit
RadioCarbon RFPD-RC-4450-50
Richardson RFPD RadioCarbon RFPD-RC-4450-50 Manuals
Manuals and User Guides for Richardson RFPD RadioCarbon RFPD-RC-4450-50. We have
2
Richardson RFPD RadioCarbon RFPD-RC-4450-50 manuals available for free PDF download: User Manual, Quick Start Manual
Richardson RFPD RadioCarbon RFPD-RC-4450-50 User Manual (54 pages)
4.4-5 GHz, 2W Linear Front-End Design Accelerator
Brand:
Richardson RFPD
| Category:
Video Card
| Size: 3 MB
Table of Contents
Table of Contents
2
Introduction - about this Document
5
RFPD-RC-4450-50 - Overview
5
Additional Heatsink
6
Figure 1: High-Level RFPD-RC-4450-50 System Block Diagram
6
Figure 2: Additional Heatsink with Thermal Tape and Screws for Additional Heat Dissipation
7
Figure 3: Heatsink Alignment
8
Figure 4: Tighten Screws
8
RFPD-RC-4450-50 Configuration - Standalone Mode
9
Figure 5: Final Assembly
9
RFPD-RC-4450-50 Initial Configuration - Standalone Mode
10
Table 2: RF Signal Path Hardware Configuration - Standalone Mode/Filter Not Bypassed
10
Table 1: GUI Initial Settings
10
Table 3: Digital Control Hardware Configurations - RFPD-RC-4450-50 Micro Control
10
Table 4: RFPD-RC-4450-50 IO Availability
11
Standalone Transmit
12
Figure 6: RFPD-RC-4450-50 RF Front End with Input/Output Interfaces
12
RF Bench Setup -Standalone Transmit
13
Figure 7: RFPD-RC-4450-50 RF Front End: Transmit Section - Standalone Mode
13
Hardware Setup - Standalone Transmit
14
DC Power Supply Connection
14
Figure 8: Suggested Configuration for RFPD-RC-4450-50 Transmit Evaluation
14
Digital/Control - USB/TTL Cable Connection
15
Figure 9: DC Voltage VIN Connection
15
RF Port Connections
16
Figure 10: ISB to TTL/UART Cable
16
Figure 11: Serial Cable Connection to J15
16
Software Setup - Standalone Transmit
17
Figure 12: Position of Coupling Capacitor C213 for Standalone Mode
17
Launch RFPD-RC-4450-50 Software App
18
Figure 13: Software Icon
18
Figure 14: Main Screen
19
Figure 15: COM Port Highlighted
19
Sequencing RFPD-RC-4450-50 PA
20
Figure 16: Auto Refresh Box Checked
20
Figure 17: PA = off → Control Box Is Green
21
Biasing the RFPD-RC-4450-50 PA
22
Figure 18: PA = on → PA Control Box Is Red
22
Figure 19: Main Screen - Setting PA Bias
23
Table 5: PA Bias Settings for Class AB Operation
23
Figure 20: PA Bias "Quick View
24
Turn RF Signal on
25
Real Time Current and Voltage Monitoring
25
Figure 21: PA Bias "Monitor
25
Real Time Temperature Sensing
26
Figure 22: Driver and Final Stage VGS/IDS Values
26
RF Detector Calibration and Measurements
27
Figure 23: RFPD-RC-4450-50 GUI Temperature Sensor Readings
27
Figure 24: Main Screen - Detector Calibration
29
Observation RX
33
RF Transmitter Performance
34
Transmitter Turn off Sequence
38
Hardware Setup - Receiver Operation
39
RX Port Selection
40
Software Setup - Receiver Operation
41
RX Frontend Configuration
42
RX Tunable Bandpass Filter
43
Turn on Receiver
45
Receiver Performance
45
Turn Receiver off
48
Alternate Configurations
48
Alterative Configurations - RF Connections for Standalone Vs. Bytepipe Vs. Tunable Filter
49
Table 6: RF Signal Path Hardware Configuration
49
Alterative Configurations - Digital Hardware Control - RFPD-RC-4450-50 Micro/Gui Vs. Bytepipe
52
Table 7: Digital Control Hardware Configurations - RFPD-RC-4450-50 Micro/Gui Vs. Bytepipe
53
Reference Information
54
Advertisement
Richardson RFPD RadioCarbon RFPD-RC-4450-50 Quick Start Manual (22 pages)
4.4-5 GHz, 2W Linear Front-End Design Accelerator
Brand:
Richardson RFPD
| Category:
Network Hardware
| Size: 1 MB
Table of Contents
Table of Contents
3
Introduction - about this Document
5
Figure 1: RFPD-RC-4450-50 Simplified Block Diagram
5
Additional Heatsink
6
Figure 2: Additional Heatsink with Thermal Tape and 4 Screws for Additional Dissipation
6
Figure 3: Heatsink Alignment
7
Figure 4: Tighten Screws
7
RFPD-RC-4450-50 Module - Standalone Mode
8
Figure 5: Final Assembly
8
Figure 6: RFPD-RC-4450-50 RF Frontend Module with Input/Output Interfaces
9
RF Bench Setup -Standalone Transmit
10
Hardware Setup - Standalone Transmit
10
Figure 7: Suggested Configuration for RFPD-RC-4450-50 Transmit Evaluation
10
DC Power Supply Connection
11
Digital/Control - USB/TTL Cable Connection
11
Figure 8: DC Voltage VIN Connection
11
RF Port Connections
12
Figure 9: USB to TTL/UART Cable
12
Figure 10: Serial Cable Connection to J15
12
Software Setup - Standalone Transmit
13
Launch Radiocarbon Software App
13
Open the App for the RFPD-RC-4450-50 Frontend Module by Clicking on the Icon
13
Figure 11: Icon
13
Figure 12: Main Screen
14
Figure 13: COM Port Highlighted
14
Biasing the Radiocarbon PA
15
Figure 14: Auto Refresh Box Checked
15
Figure 15: Main Screen - Setting PA Bias
16
Table 1: PA Bias Settings for Class AB Operation
16
Figure 16: PA Bias "Quick View
17
Turn RF Signal on
18
Transmitter Turn off Sequence
18
Figure 17: PA Power-Down
18
Hardware Setup - Receiver Operation
19
Figure 18: Idq Verification
19
Software Setup - Receiver Operation
20
Figure 19: Receiver Test Bench Setup
20
Figure 20: Main Window - Frontend
21
Turn Receiver off
22
Advertisement
Related Products
Richardson RFPD RADIOCARBON-13
Richardson RFPD Categories
Network Hardware
Video Card
Control Unit
More Richardson RFPD Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL