Sign In
Upload
Manuals
Brands
REMEHA Manuals
Heat Pump
Mono 2 AWHP 10MR
REMEHA Mono 2 AWHP 10MR Manuals
Manuals and User Guides for REMEHA Mono 2 AWHP 10MR. We have
1
REMEHA Mono 2 AWHP 10MR manual available for free PDF download: Installation, User And Service Manual
REMEHA Mono 2 AWHP 10MR Installation, User And Service Manual (156 pages)
Reversible monobloc air-to-water heat pump
Brand:
REMEHA
| Category:
Heat Pump
| Size: 37 MB
Table of Contents
Table of Contents
2
Safety Instructions
6
Standard Delivery
9
Symbols Used
9
Symbols Used in the Manual
9
Symbols Used on the Indoor Unit
9
Symbols Used on the Condensate Pan
10
Symbols Used on the Data Plate
10
Technical Specifications
10
Homologations
10
Directives
10
Factory Test
11
Bluetooth ® Wireless Technology
11
Technical Data
11
HP Keymark Registration Number for the Outdoor Unit
11
Heat Pump
11
Space Heaters with Medium-Temperature Heat Pump
13
Heat Pump Weight
16
Sensor Specifications
16
Circulating Pump
16
Dimensions and Connections
18
Indoor Unit
18
Outdoor Unit Mono 2 AWHP 4MR Mono 2 AWHP 6MR
19
Outdoor Unit Mono 2 AWHP 8MR Mono 2 AWHP 10MR Mono 2 AWHP 12TR Mono 2 AWHP 16TR
19
Electrical Diagram
20
Description of the Product
22
Data Plates
22
Bluetooth ® Label
23
Main Components
24
Description of the Connection Terminal Blocks
27
Main PCB EHC-10
27
Power Supply Terminal Block for the Indoor Unit, LIN Central Heating Pump and Accessories
27
Terminal Block for Outdoor Unit Connection
27
BLE Smart Antenna PCB for Bluetooth ® Communication
28
SCB-17B Second and Third Circuit PCB
28
SCB-01 PCB Option for the Summer/Winter Transition and Connecting a 0-10V Backup Boiler
28
PCB Option GTW-08 for Connecting to a Building Management System
28
Description of the User Interface
29
Description of the Interface
29
Description of the Standby Screen
29
Description of Status Icons
29
Description of the Home Screen
30
Description of the Zone Display
30
Description of the Carousel
30
Installation
31
Installation Regulations
31
Respecting the Maximum Pipe Length between the Indoor Unit and the Outdoor Unit
31
Putting the Outdoor Unit in Place
32
Allowing Sufficient Space for the Outdoor Unit
32
Selecting the Location of the Outdoor Unit
32
Choosing the Location of a Noise Abatement Screen
33
Selecting the Location of the Outdoor Unit in Cold and Snowy Regions
33
Installing the Outdoor Unit
34
Removing the Protection from the Outdoor Unit
34
Positioning the Indoor Unit
35
Choosing the Location of the Indoor Unit
35
Installation in a Cupboard
35
Attaching the Indoor Unit to the Wall
36
Hydraulic Connections
37
Special Precautions for Connecting the Heating Circuit
37
Low Loss Header
37
Minimum Volume of Water
38
Volume of the Expansion Vessel
38
Adapting the Pipes between the Indoor Unit and the Outdoor Unit
39
Connections
39
Frost Protection
42
Installing a Domestic Hot Water Tank
42
Connecting the Condensate Drain
42
Accessing the Pcbs and Connection Terminal Block
43
Electrical Connections
44
Checking and Preparing the Electrical Installation
44
Connecting the Electrical Circuits
45
Routing of the Cables in the Indoor Unit
46
Connecting the Indoor Unit
47
Connecting the Outdoor Unit to the Power Supply
48
Connecting the Outdoor Unit to the Indoor Unit
49
Fitting the Outdoor Temperature Sensor
49
Connecting a Backup Heater
50
Connecting a Backup Boiler
51
Connecting the Heating Element Power Supply
51
Connecting an LIN Central Heating Pump
53
Connecting the Options
53
Connecting an Electricity Meter
54
Checking the Electrical Connections
54
Flushing the Installation
54
Flushing New Installations and Installations Less than 6 Months Old
54
Flushing an Existing Installation
55
Filling and Checking the Installation
55
Heating Water Specifications
55
Filling the Heating Circuit
55
Checking the Heating Circuit
56
Commissioning
56
General
56
Action to be Taken before Commissioning
56
Commissioning Procedure with Smartphone
57
Commissioning Procedure Without Smartphone
57
Configuration Numbers CN1 and CN2
58
Configuring the Maximum Current ODU Parameter for the Mono 2 AWHP 10MR Outdoor Unit
58
Final Instructions for Commissioning
59
Settings
59
Accessing the Installer Level
59
Activating/Deactivating the Bluetooth ® for the Appliance
59
Searching for a Parameter or a Measured Value
60
Configuring the Heating Circuit
60
Setting the Circuit Function
60
Setting the Heating Curve
60
Configuring the Cooling Function
61
Configuring the Backup Boiler Parameters
62
Configuring the Control for a 0-10V Backup Boiler
62
Authorising the Assisted Hydronic Balancing
62
Drying the Screed
63
Configuring a Room Thermostat
64
Configuring an On/Off or Modulating Thermostat
64
Configuring a Thermostat with a Heating/Cooling Control Contact
65
Configuring the Anti-Legionella Function
67
Configuring a Buffer Tank
68
Configuring a DHW Circulation Loop
68
Improving Comfort
69
Improving Domestic Hot Water or Heating Comfort
69
Configuring Silent Mode
70
Configuring Sources of Energy
70
Configuring the Electrical Energy Consumption Function
70
Supplying the Heat Pump with Photovoltaic Energy
71
Connecting the Installation to a Smart Grid
72
Configuring the Multifunctional Output
73
Resetting or Re-Establishing the Parameters
73
Resetting the Configuration Numbers
73
Auto-Detecting Options and Accessories
74
Reverting to the Factory Settings
74
Parameters
74
List of Parameters
74
Installer > Installation Setup > Heat Pump
74
Installer > Installation Setup > Zone 1 or Zone 2 or Zone 3
78
Installer > Installation Setup > Domestic Hot Water (Domestic Hot Water)
82
Installer > Installation Setup > Outdoor Temperature
84
Bluetooth
84
Installer > Installation Setup > SCB-01
85
Installer > Signals
86
Installer > Counters
88
Description of the Parameters
90
Running the Back-Up in Heating Mode
90
Running the Back-Up in Domestic Hot Water Mode
91
Operation of the Switch between Heating and Production of Domestic Hot Water
91
Operation of the Heating Curve
92
10 Connection and Installation Examples
94
Installation with Backup Boiler and One Direct Circuit
94
Hydraulic Diagram
94
Connecting and Configuring the Heat Pump
95
Installation with Electric Heating Element, Underfloor Heating and Domestic Hot Water Tank
97
Hydraulic Diagram
97
Connecting and Configuring the Heat Pump
98
Installation with Heating Element, Underfloor Heating, Solar Collectors and DHW Cylinder
100
Hydraulic Diagram
100
Connecting and Configuring the Heat Pump
101
Installation with Electric Heating Element, Two Circuits and a Low-Loss Header
103
Hydraulic Diagram
103
Connecting and Configuring the Heat Pump
104
Installation with Heating Element, Two Circuits and One Domestic Hot Water Tank with Recirculation Loop
106
Hydraulic Diagram
106
Connecting and Configuring the Heat Pump
107
Installation with a Swimming Pool
109
Connecting a Swimming Pool
109
Configuring Swimming Pool Heating
110
11 Operation
110
Activate/Deactivate the Child Lock
110
Regional and Ergonomic Parameters
110
Personalising the Zones
111
Definition of the Term "Zone
111
Changing the Name and Symbol for a Zone
111
Personalising the Activities
112
Definition of the Term "Activity
112
Changing the Name of an Activity
112
Changing the Temperature of an Activity
112
Room Temperature for a Zone
113
Selecting the Operating Mode
113
Activating and Configuring a Timer Programme for Heating
113
Activating and Configuring a Timer Programme for Cooling
114
Changing the Room Temperature Temporarily
115
Domestic Hot Water Temperature
116
Selecting the Operating Mode
116
Activating and Configuring a Timer Programme for Domestic Hot Water
116
Forcing Domestic Hot Water Production (Override)
117
Modifying the Domestic Hot Water Setpoint Temperatures
118
Managing the Heating, Cooling and Domestic Hot Water Production
118
Shutting off the Heating and Cooling
118
Forcing Cooling
119
Shutting off the Heating in Summer
119
Shutting off Domestic Hot Water Production
119
Periods of Absence or Going on Holiday
120
Frost Protection
121
Monitoring the Energy Consumption
121
Starting and Stopping the Heat Pump
122
Starting the Heat Pump
122
Shutting down the Heat Pump
122
11.10 in Case of a Prolonged Power Outage in the Winter
122
12 User Instructions
123
Prolonged Power Outage in Winter
123
Draining an Installation Equipped with Anti-Freeze Valves
123
Draining an Installation Equipped with Manual Drain Valves
123
13 Maintenance
124
General
124
Information for Service Personnel
124
Checking Operation of the Appliance
125
Draining the Heating Circuit
125
Check the Hydraulic Pressure
126
Cleaning the Magnetic Sieve Filters
126
Flushing the Magnetic Screen Filters (Quick Annual Maintenance)
126
Full Cleaning of the Magnetic Sieve Filters
127
Checking the Safety Components
127
Replacing the User Interface Battery
128
14 Troubleshooting
128
Resolving Operating Errors
128
Types of Error Code
128
Warning Codes
129
Blocking Codes
129
Lockout Codes
136
Displaying and Clearing the Error Memory
136
Accessing Information on the Hardware and Software Versions
137
Resetting the Safety Thermostat
137
15 Decommissioning and Disposal
138
Decommissioning Procedure
138
Disposal and Recycling
138
16 Spare Parts
139
Electrical Wire Harnesses
139
Mercuria E MB with Heating Element
141
Mercuria H MB with Hydraulic Backup
144
17 Product Fiche and Package Fiche
147
Product Fiche
147
Product Fiche - Temperature Controller
148
Package Fiche - Combination Heaters (Boilers or Heat Pumps)
148
Package Fiche - Medium-Temperature Heat Pumps
149
18 Appendix
151
Name and Symbol of the Zones
151
Name and Temperature of the Activities
151
Advertisement
Advertisement
Related Products
REMEHA Mono 2 AWHP 12TR
REMEHA Mono 2 AWHP 16TR
REMEHA Mono 2 AWHP 4MR
REMEHA Mono 2 AWHP 6MR
REMEHA Mono 2 AWHP 8MR
REMEHA 1000 Indirect
REMEHA Gas 110 Eco 65
REMEHA Rematic 142
REMEHA 1450 Indirect
REMEHA Gas 120 ACE - 115
REMEHA Categories
Boiler
Thermostat
Controller
Boiler Supplies
Heat Pump
More REMEHA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL