Sign In
Upload
Manuals
Brands
RADWAG Manuals
Touch Panel
PUE HX5.EX
RADWAG PUE HX5.EX Weighing Terminal Manuals
Manuals and User Guides for RADWAG PUE HX5.EX Weighing Terminal. We have
3
RADWAG PUE HX5.EX Weighing Terminal manuals available for free PDF download: Software Manual, User Manual, Quick Start Manual
RADWAG PUE HX5.EX Software Manual (96 pages)
Brand:
RADWAG
| Category:
Accessories
| Size: 1.84 MB
Table of Contents
Table of Contents
3
1 Intended Use
6
2 Operation Panel
7
3 Start-Up
8
4 Home Screen
8
Top Bar
9
Weighing Result Window
9
Workspace
9
Pictograms
9
5 Operating the Menu
10
Entering the Menu
10
Menu Keys
10
Entering Numeric and Text Characters and Signs
11
Numerical Box
11
Text Box
13
Diacritical Signs Table
15
Special Signs Table
15
Return to Weighing
15
6 Program
16
7 Log in Operation
16
Log in Procedure
17
Log out Procedure
17
Permission Levels
17
8 Weighing
18
Zeroing
18
Taring
18
Dual Range Devices
19
Weighing Unit Change
19
Setting MIN, MAX Thresholds
20
Setting MIN, MAX Threshold Using Programmable Button
20
Setting MIN, MAX Thresholds by Product Selection
21
Setting MIN, MAX Threshold Using Proximity Sensor
21
Setting MIN, MAX Threshold Using Digital Input
21
9 Communication
22
Rs232
22
Rs485
22
Ethernet
23
Usb
23
10 Peripheral Devices
24
IM01.EX Communication Module
24
Connecting IM01.EX to the Mains
24
Connecting IM01.EX Module and PUE HX5.EX Indicator
24
Activation of Connection between the IM01.EX Module and HX5.EX Scale
24
Computer
25
Computer Port
25
Address
26
Weighing Printout Template
26
Continuous Transmission
26
Printout Interval
27
PUE HX5.EX and E2R System
27
Printer
27
Printer Port
28
Code Page
28
Prefix, Suffix
29
Record of Measurement Data Onto a USB Flash Drive
30
Barcode Scanner
30
Barcode Scanner Port
30
Offset
31
Length of Code
31
Prefix, Suffix
31
Field Selection
32
Filtering
32
Test
32
Additional Display
33
Additional Display Port
33
Bottom Text Area Template
33
11 Printouts
34
Print Mode: Header - GLP Printout - Footer
34
Non-Standard Printouts
36
Adjustment Report
37
Dosing Report
37
Formulation Report
38
12 Inputs / Outputs
39
Input Setup
39
Output Setup
39
13 Display
41
Workspace
41
Label
41
Text Box
43
Bar Graph
43
Keys
45
Default Screen Settings
47
14 Permission Levels
47
Anonymous Operator
47
Date and Time
48
Printouts
48
Databases Edition
48
Select Database Record
49
15 Units
49
Units Availability
49
Start Unit
50
Gravitational Acceleration
50
Custom Units
50
16 Miscellaneous Parameters
51
Interface Language
51
Display Brightness
51
Date and Time
51
Backlight Standby Time
52
Automatic Shutdown
52
Default Operator Settings
52
17 Adjustment
53
External Adjustment
53
User Adjustment
53
Start Mass Determination
54
Adjustment Report
54
18 Scale Data
54
19 Working Modes - General Information
55
Running Working Mode
55
Working Mode Accessibility
55
20 WORKING MODES - Local Settings
55
Readout
56
Save Mode
57
Auto Threshold
57
Result Control
57
Autotare
58
Labelling Mode
58
Automatic C Label Triggering
59
Statistics
60
21 Working Mode - Weighing
60
Home Screen
60
Local Settings
61
22 Working Mode - Parts Counting
61
Home Screen
61
Function of Automatic Correction of Reference Sample Mass
62
Minimum Reference Sample Mass
63
Setting Reference Sample Mass by Entering Mass of a Single Part
63
Setting Reference Sample Mass by Determining Mass of a Single Part
63
Setting Reference Sample Mass by Acquiring Mass of a Single Part from Database
64
Entering Reference Sample Mass to Weighing Device Memory
64
23 Working Mode - Percent Weighing
65
Home Screen
65
Local Settings
65
Reference Sample Mass Determined by Weighing
66
Reference Sample Mass Entered to the Weighing Device Memory
66
Setting Reference Sample Mass by Acquiring Mass of a Single Part from Database
66
24 Working Mode - Dosing
66
Home Screen
67
Local Settings
67
Automatic Dosing Procedure
69
Manual Dosing Procedure
71
Dosing Process Report
73
25 Working Mode - Formulations
73
Home Screen
73
Local Settings
74
New Formulation
74
Formulation Procedure
75
Formulation Report
77
26 Databases
78
Database Export
78
Database Import
79
Adding Database Record
79
Deleting Database Record
80
Deleting Database Content
80
Databases Edition
80
Operators
80
Products
80
Formulations
81
Packaging
82
Customers
82
Labels
82
Universal Variables
83
27 Reports
83
Deleting Weighings Report
84
Reports Preview
84
Weighings
84
Alibi
85
Dosing Reports
85
Formulations Reports
85
28 Import / Export
86
Data Export
86
Data Import
87
29 Error Messages
88
30 ANNEX 01 - Printout Variables
88
Variables List
88
Variables Formatting
90
31 ANNEX 02 - Label Template
93
Creation of Label Template Via the Scale
93
Sending Label Template to Scale Memory
93
Assigning a Label with a Template to a Product
93
Assigning a C Label with a Template to a Product
94
Assigning a Label with a Template to a Customer
94
Printing a Label with a Template
94
32 ANNEX 03 - ZEBRA Printer Configuration
94
33 ANNEX 04 - Barcode Scanner Configuration
95
Advertisement
RADWAG PUE HX5.EX User Manual (52 pages)
WEIGHING INDICATOR
Brand:
RADWAG
| Category:
Touch Panel
| Size: 1.88 MB
Table of Contents
Table of Contents
4
1 Intended Use
6
2 Usage Conditions
6
Supplying the PUE HX5.EX-* Indicator with Power
6
Electrostatic Charges Hazard
7
Device with Permanently Fixed Wires
7
Load Cells
7
3 Warranty Conditions
7
4 Safety Requirements
8
ATEX Markings - Symbols Meaning
9
Data Plates
10
Information Stickers Arrangement
11
5 Technical Condition Inspection
11
6 Maintenance Activities
12
7 Service and Repair
12
8 Utilisation
13
9 Mechanical Design
13
Main Components
13
Overall Indicator Dimensions
15
Operation Panel
15
Technical Specifications
17
Models
17
Connectors Arrangement
17
RS232, RS485 Connectors
18
Pins Assignment
19
Intrinsic Safety Parameters
19
Digital Inputs and Outputs
20
In/Out Cables Marking
20
Intrinsic Safety Parameters for IN/OUT Circuits
21
Technical Specifications for IN/OUT
22
Permissible Inputs/Outputs Configuration
22
Active Inputs
22
Passive Inputs in Ex Zone
23
Passive Inputs Outside Ex Zone
23
Active Outputs
25
Passive Outputs in Ex Zone
25
Passive Outputs Outside Ex Zone
26
10 Installation
28
Unpacking and Preparing for Operation
28
Workstation
28
Grounding
29
Connecting Power Supply
30
11 Start-Up
32
12 Home Screen
32
Top Bar
32
Weighing Result Window
33
Workspace
33
Pictograms
33
13 Operating the Menu
34
Entering the Menu
34
Menu Keys
34
Entering Numeric and Text Characters and Signs
35
Return to the Weighing Mode
35
14 Installer Instruction
36
Connecting Load Cells - PLATFORM Analog Interface
36
Intrinsic Safety Parameters
38
6-Wire Load Cell Connection
38
4-Wire Load Cell Connection
39
Multiple Load Cells Connection
40
Load Cell Platforms
40
Weighing Modules - Solder Type Connection
41
Weighing Modules - Connections on Junction Box Board
42
15 Factory Setup
42
Access to Factory Setup
42
Global Parameters List
43
Factory Parameters List
44
Factory Adjustment
45
External Adjustment
45
Start Mass Determination
46
Linearity Correction
46
Linearity Determination
46
Corrections
47
Deleting Linearity
47
Gravitational Coefficient
48
16 Connection Cables List
48
17 Standards List
48
RADWAG PUE HX5.EX Quick Start Manual (12 pages)
Brand:
RADWAG
| Category:
Measuring Instruments
| Size: 1.65 MB
Table of Contents
Notes and Warnings
3
Preparing for Work
4
Power Supply Connection Diagram
4
Home Screen
6
Working Modes
6
Unit Selection
7
Connecting Peripherals
7
Cleaning and Maintenance
8
Cleaning Tips
8
Advertisement
Advertisement
Related Products
RADWAG PUE HY10
RADWAG PUE HX7
RADWAG PUE H315
RADWAG PUE 7.1
RADWAG PUE 5.19
RADWAG PUE C315
RADWAG PUE C/31H
RADWAG PUE CY10
RADWAG PUE C/31H/Z
RADWAG PUE 7.1P
RADWAG Categories
Scales
Measuring Instruments
Accessories
Laboratory Equipment
Media Converter
More RADWAG Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL