PROTEA P2000 Manuals
Manuals and User Guides for PROTEA P2000. We have
2
PROTEA P2000 manuals available for free PDF download: Operating Manual
PROTEA P2000 Operating Manual (280 pages)
Analyser Unit
Brand:
PROTEA
| Category:
Measuring Instruments
| Size: 9 MB
Table of Contents
Section 1
15
Table of Contents
15
Introduction
19
About this Manual
19
About the P2000 Series
21
P2000 - an Overview
21
Analyser Identification
25
Further Information
26
Installation
29
Introduction
32
Unpacking the System Components
32
Pre-Installation Information
35
Location
36
Preparing the Process Gas Duct
37
Re-Fitting Insulation
40
Drilling the Control Unit Gland Plates
41
Preparing the Analyser Unit for Wiring
43
Wiring Tables
46
Analyser Covers
52
Integral Auto Verification Unit
55
Commissioning
62
Introduction
64
Mounting of CEM System Components
64
Connection of Instrument Air Supply
67
Connection of Communication
67
Connections to the AC Power Source
68
Insertion and Wiring of In-Situ Heater
70
Insertion of the Analyser
70
Stack Process Conditions & Operational Readings
71
Introduction
75
Operation
75
Introduction
77
P2000 Technical Specification
77
Technical Specification
77
Auto Verification Unit Specification
82
Inspection Schedules
84
Introduction
87
Nature and Frequency of Inspections
88
Quarterly (Three Monthly) Schedule
88
Annual Schedule
93
Obtaining Further Data in the Case of a Fault
94
Cleaning
95
Field Gas Calibration Check
95
Fault-Finding and Repair Policy
99
Spares List
100
Disposal of Stored Data
103
Disposal Instructions
103
Introduction
103
Transport & Storage Instructions
106
Order-Specific Information
112
Appendix A - the P2000 with Atex/Iecex Approvals
114
Introduction
114
Quality Assurance During Production
114
Allowed Environments
115
Maintenance Additional Requirements
116
Special Conditions for Safe Use
118
Appendix B - P2000 with MCERTS Approval
124
Introduction
124
Quality Assurance During Production
125
Maintenance Additional Requirements
126
Services
127
Introduction
127
Appendix C - Protea Analysers for US EPA Compliance
127
Operation
128
Action on Calibration Error
131
Viewing the Results
131
Electrical Connections
132
Appendix D - Quality Standard for Instrument Air Supplied to Protea Analysers
133
Introduction
133
Appendix E - Air Preparation Panel
136
Introduction
136
Appendix F - Power Supply Unit
138
Introduction
138
Appendix G - In-Situ Heater
140
Introduction
140
In-Situ Heater Description
140
Technical Specification
141
Minimum Mains Cable Specification
141
Control Cable Specification
142
Fitting the In-Situ Heater
142
Appendix H - Hot Access Port
147
Introduction
147
Operation
147
Drawings
149
Appendix I - by Pass
152
Introduction
152
By-Pass Description
152
Fitting the Optional By-Pass
154
Connecting the Heater
158
Appendix J - In-Situ Steam Heater
162
Introduction
162
In-Situ Steam Heater Description
162
Fitting the In-Situ Steam Heater
163
Appendix K - Steam Heated by Pass
165
Introduction
165
By-Pass Description
165
Fitting the Optional Steam Heated By-Pass
166
Appendix L - P2000D (UV Diode)
170
Introduction
171
Maintenance of the P2000D
173
Replacing the UV Source
175
In-Service History
180
Section 2
183
Product Overview
186
Installing the USB Driver
188
Installing the Utility Software and Configuring USB
188
Minimum Hardware/Software Specification for Host PC
188
Assigning a Valid COM Port
189
Installing the Utility Software
189
Updating the Utility Software
189
Connecting a PC to the DSL-330
191
Using the Utility Software
191
The Comms Tab
192
Connect to Instrument
193
Connect through OI
195
Enable Multidrop
195
Bus Comms (RS485)
196
Reading
197
Reading Override Mode
197
The Readings Tab
197
Negative Clipping
198
Damping
199
Log Reading - Append to File
199
Log Reading - Enabled
199
Log Reading - Log Q and a
199
Graph Button
200
Log Reading - Interval
200
Fault Messages
201
Warning Messages
202
Analogue Output
203
The Outputs Tab
203
4-20Ma Output
204
Analogue Low and Analogue High
204
Relay Polarity Checkbox
204
Relays
204
Delay
205
Threshold
205
The Settings Tab
206
AGC Button
207
Alignment Tool Button
207
Gain
207
Measure Signal
207
Mkiii Double Pass Particulate Monitor (Mg/M ) - Operators Manual
207
Reference Signal
207
Signal Strength
207
Temperature
207
Calibration
208
Density Scale Value
208
Path Length
208
Zero Adjust Button
208
Zero Adjust Value
208
Enable Opacity
209
Opacity
209
Absolute Span Drift
210
Absolute Zero Drift
210
Cal Check Button
210
Calibration Checking
210
Reference Cal Button
210
Firmware / PCB Serial Number / Compile Time
212
Instrument Information
212
The Diagnostics Tab
212
Backup to PC
213
Restore Factory Defaults
213
Restore from PC
213
Direct Comms
214
Folder Location
214
Keypad / Display Fundamentals
215
Using the OI
215
Moving between Pages
217
Danp (Damping)
218
Dust (Reading)
218
Page 0 Parameters
218
Alr (Level Alarm)
219
Anlo & Anhi (Analogue Low & Analogue High)
219
Dly (Level Alarm Delay)
219
Nna (4-20Ma Output)
219
Drif (Absolute Zero and Span Drift)
220
Page 1 Parameters
220
Rly (Relay Polarity)
220
Def (Restore Factory Defaults)
221
Dust (Reading)
221
Ref (Reference Signal)
221
Sig (Measure Signal)
221
Agc (AGC)
222
Gain (Gain)
222
Path (Path)
222
SCAL (Density Scale Value)
222
Tenp (Temperature)
222
Zadj (Zero Adjust)
222
Ccal (Calibration Check)
223
Mkiii Double Pass Particulate Monitor (Mg/M ) - Operators Manual
223
Negative Clipping
223
Rcal (Reference Calibration)
223
Overview
224
Set-Up, Calibration and Commissioning
224
Head Alignment
226
Automatic Gain Correction (AGC)
229
Performing a Zero Adjust
231
Defining the Path Length for Particle Density
232
Upscale Calibration
232
Configuring the Outputs
234
Calibration Checking
235
Reference Calibration
236
Reference Calibration Using the Utility Software
237
Step1
237
Step 2
238
Step 3
239
Step 4
240
Exiting
242
Reference Calibration Using the OI
243
Calibration Check
246
Calibration Check Using the Utility Software
246
Step 1
247
Step 2
248
Step 3
249
Results
251
Exiting
252
Calibration Check Using the OI
253
Relative and Absolute Drift
256
Cleaning the Lenses
257
Maintenance
257
Checking the Reference Signal
258
Fault Messages and Trouble Shooting
259
Fault Messages
260
HI REF-VIS ("Hi R")
260
LO REF-VIS ("Lo R")
260
Head" (Only Displayed on the OI)
261
HI MEAS-VIS ("Hi S")
261
Override Active
261
Alarm Active
262
MEMORY FAULT ("Eech")
262
Warning Messages
262
COMMS CRC FAULT ("Crc")
263
Revision Control
264
Section 3
267
Preface
269
Before You Begin
270
Manual Conventions
270
Using this Manual
270
Installation
271
Overview
271
Hardware Description
272
Unpacking
272
Insertion Flow Meters
273
Installation Requirements
273
Insertion Flow Meter Guidelines
275
In-Line Flow Meter Guidelines
276
In-Line Flow Meters
276
Wiring Requirements
277
K-BAR Flow Meter System
278
Multipoint Flow System Guidelines
278
K-BAR Configuration
279
Advertisement
PROTEA P2000 Operating Manual (91 pages)
Analyser Unit
Brand:
PROTEA
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
Introduction
5
About this Manual
5
About the P2000 Series
5
P2000 - an Overview
6
Screen Displays
8
Analyser Identification
9
Further Information
9
Installation
11
Introduction
11
Unpacking the System Components
11
Pre-Installation Information
12
Preparing the Process Gas Duct
13
Preparing the Analyser Unit for Wiring
15
Wiring Table
17
Analyser Covers
19
Auto Zero / Verification Units
22
Verifying Correct Zero / Test Gas Flow Rate
23
Operation
25
Introduction
25
Technical Description
27
Introduction
27
Infra-Red Absorption Theory
27
IR Theory Applied to the P2000
29
Cross-Sensitivity
30
Gas Filter Correlation
30
Analyser Unit
34
Integral Auto Verification Unit
36
Maintenance
39
Introduction
39
Routine Maintenance Schedule
39
Annual Schedule
40
Cleaning
40
Field Calibration Check
41
Calibration Equipment
41
Sintered Panel Flow Test
42
Fault-Finding
45
Repair Policy
46
Spares List
47
Changing P2000 Components
47
Changing the Filter Wheel Motor
50
Disposal Instructions
51
Introduction
51
Zinc Selenide Optics
51
Order-Specific Information
53
Introduction
53
Appendix A - the P2000 with Atex/Iecex Approvals
55
Introduction
55
Quality Assurance During Production
55
Allowed Environments
56
Installation Additional Requirement
57
Maintenance Additional Requirements
57
Conditions of Safe Use
58
Appendix B - Quality Standard for Instrument Air Supplied to Protea Analysers
59
Introduction
59
Appendix C - In-Situ Heater
61
Introduction
61
In-Situ Heater Description
61
Fitting the In-Situ Heater
61
Appendix D - Protea Analysers for US EPA Compliance
65
Introduction
65
Services
65
Operation
66
Action on Calibration Error
68
Viewing the Results
68
Electrical Connections
68
Appendix E - Hot Access Port
69
Introduction
69
Operation
69
Drawings
70
Appendix F - by Pass
73
Introduction
73
By-Pass Description
73
Fitting the Optional By-Pass
74
Connecting the Heater
76
Appendix G - In-Situ Steam Heater
79
Introduction
79
In-Situ Steam Heater Description
79
Fitting the In-Situ Steam Heater
80
Appendix H - Steam Heated by Pass
83
Introduction
83
By-Pass Description
83
Fitting the Optional Steam Heated By-Pass
84
Appendix I - Air Preparation Panel
87
Introduction
87
Appendix J - P2000 with MCERTS Approval
89
Introduction
89
Quality Assurance During Production
90
Maintenance Additional Requirements
90
In-Service History
91