Sign In
Upload
Manuals
Brands
Procentec Manuals
Media Converter
VPGate
Procentec VPGate Manuals
Manuals and User Guides for Procentec VPGate. We have
4
Procentec VPGate manuals available for free PDF download: User Manual, Manual
Procentec VPGate User Manual (135 pages)
MODBUS/TCP to Serial
Brand:
Procentec
| Category:
Gateway
| Size: 7 MB
Table of Contents
Table of Contents
2
1 Characteristics
6
General Characteristics
6
Electrical Characteristics
8
Mechanical/Environmental Characteristics
8
2 Hardware Installation
9
Connector
9
Power Connector
9
SERIAL Connector
9
Digital Input
10
Digital Output
10
Front Panel Indicators
10
Indicator Light of the 2 Ports Switch
11
DIP Switches
11
Default Configuration of the IP Address
11
Choosing the RS-232/RS-485 Mode
12
Terminating Resistance
12
3 Working Principle
14
Appliance of the Product
14
Default Configuration
14
Configuration in "Advanced Gateway" Mode
15
MODBUS/TCP Server
17
MODBUS/TCP Client
18
MODBUS Serial Link Master (1)
19
MODBUS Master with the "Direct Messaging" Function
19
Fault Management in Direct Messaging
20
MODBUS Master Scenarios
21
MODBUS Serial Link Slave (2)
22
Transparent Mode (3)
23
Case Where the End of the Frame Is Detected Thanks to a Special Character
23
Case Where the Length of Frame Is Known
24
Case Where the End of the Frame Is Detected Following Timeout
25
Functioning of the Frame Trigger
25
Principle of Configuration of the Product
26
4 Software Configuration
27
Procedure to Access the Vpgate Web Server
27
Procedure for Configuring the Serial Link
28
Procedure for Configuring the MODBUS/TCP Server
29
Procedure for Configuring the MODBUS Serial Link Master
30
Procedure for Configuring the MODBUS Serial Link Slave
31
Procedure for Configuring Transparent Mode
32
5 Implementation of the Default Configuration
33
Configuration of the IP Address Using the DIP Switch
33
Configuration of the IP Address Using the DCP Protocol
37
Configuration of the Serial Link
39
Operating Test of the Default Gateway
41
6 Implementation of the Advanced Configuration
42
MODBUS/TCP Server
42
General Information Regarding the MODBUS/TCP Server
43
Configuration of the MODBUS/TCP Server
44
MODBUS/TCP Client
45
Activation of the MODBUS/TCP Client
45
Creation of Scenarios for the MODBUS/TCP Client
45
Status of Scenarios for the MODBUS/TCP Client
49
Deactivation of a MODBUS/TCP Client Scenario
50
Modification or Deletion of a MODBUS/TCP Client Scenario
50
Backing-Up the List of MODBUS/TCP Scenarios
51
Modbus Master
52
Activation of the MODBUS Serial Link Master
52
Configuration of the MODBUS Serial Link Master
52
Creation of the MODBUS Serial Link Master Scenarios
54
Status of the MODBUS Serial Link Master Scenarios
58
Deactivation of a MODBUS Serial Link Master Scenario
59
Modification or Deletion of a MODBUS Serial Link Master Scenario
59
Backing-Up the List of MODBUS Master
60
Modbus Slave
61
Activation of the MODBUS Serial Link Slave
61
Configuration of the MODBUS Serial Link Slave
61
Transparent Mode
63
Activation of the MODBUS Serial Link Slave
63
Configuration of Transparent Mode on the Serial Link
64
7 Digital Input/Output
67
Configuration of the Digital Input/Output
67
8 Diagnostics
68
Explanation of the Leds
68
Diagnostics with Status of MODBUS Master Scenarios
69
Diagnostics with Status of the MODBUS/TCP Client Scenarios
70
Statistics of the MODBUS Master
72
Web Page of the MODBUS Slave Statistics
73
9 Web Server
74
Presentation of the Web Server
74
Management of Access to the Web Server
75
System Information" Menu
76
Network Settings" Menu
76
Gateway Mode" Menu
77
Modbus/Tcp Settings" Menu
77
Serial Settings" Menu
77
IO Settings" Menu
77
SNMP Information" Menu
78
ETHERNET Statistics" Menu
78
MODBUS Statistics" Menu
80
File System" Menu
81
Firmware Upload" Menu
82
Reboot" Menu
83
Passwords" Menu
83
Logout" Menu
84
Custom" Menu / Customised WEB
84
Access to Data Via Personalised Web
84
Example of Customised WEB
85
10 FTP Server
87
11 SNMP Agent
88
12 Appendices
90
APPENDIX A: Format of the MODBUS Frames
90
APPENDIX C: API CGI Javascript
104
APPENDIX E: MIB2, Important Fields
115
13 Other PROCENTEC Products
124
14 Sales Offices and Distributors
126
15 About PROCENTEC
131
16 Notes
132
Advertisement
Procentec VPGate Manual (109 pages)
Ethernet/IP to Modbus Serial
Brand:
Procentec
| Category:
Gateway
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Properties
5
General Properties
5
Electrical Properties
7
Mechanical Properties
7
2 Hardware Installation
8
Connectors
8
Power Connector
8
SERIAL Connector
8
ETHERNET RJ45 Connectors P1 and P2
9
TOR Input
9
TOR Output
9
Indicators
10
Front Panel Indicators
10
Indicators on the 2 ETHERNET Connectors
10
DIP Switches
11
Default Configuration of the IP Address
11
Choosing the RS232/RS485 Mode
11
Termination Resistance
12
3 Ethernet/Ip
13
Operating Principle
13
Implicit Messaging
13
Explicit Messaging
13
List of Available Ethernet/Ip™ Objects
14
Identity Object
14
Instance Attributes
14
Instance Services
15
Assembly Object
16
Class Attributes
16
Instance List
16
Instance Attributes
17
Connection Manager Object
18
Class Attributes
18
Class Services
18
Instance Attributes
18
Instance Services
19
MODBUS Object (Vendor Specific)
20
Operating Principle
20
Class Attributes
21
Class Service
21
Object-Specific Services
21
Read_Discrete_Inputs Service
22
Read_Coils Service
22
Read_Input_Registers Service
23
Read_Holding_Registers Service
23
Write_Coils Service
24
Write_Holding_Registers Service
25
Error Checking
26
TCP/IP Interface Object
27
Class Attributes
27
Instance Attributes
27
Instance Services
29
Ethernet Link Object
30
Class Attributes
30
Class-Specific Service
30
Instance List
30
Instance Attributes
30
Instance Services
31
4 Software Configuration
32
Configuration of the Ethernet/Ip™ Scanner
32
Integrating the VPGATE in a Project
32
Importing an EDS File into the Engineering Tool
32
Integrating the VPGATE in a Configuration Tool
33
Integration by Network Detection
33
Manual Integration
36
General Configuration of VPGATE
40
Exclusive Owner Connection for MODBUS Master Mode
41
Operating Principle
41
Configuration
41
Input Assembly (T O)
41
Output Assembly (O T)
42
Configuration Assembly
42
Setting MODBUS Master Mode in a Configuration Tool
45
MODBUS Master Behaviour According to Ethernet/Ip™ Connection Status
46
Exclusive Owner Connection for MODBUS Slave Mode
47
Operating Principle
47
Configuration
47
Input Assembly (T O)
47
Output Assembly (O T)
48
Configuration Assembly
48
Setting MODBUS Slave Mode in a Configuration Tool
49
Exclusive Owner Connection for TRANSPARENT Mode
52
Operating Principle
52
Configuration
54
Input Assembly (T O)
55
Output Assembly (O T)
55
Configuration Assembly
55
Setting TRANSPARENT Mode in a Configuration Tool
59
Input Only Connection
60
Input Assembly (T O)
60
Output Assembly (O T)
61
Configuration Assembly
61
Listen Only Connection
62
Input Assembly (T O)
62
Output Assembly (O T)
62
Configuration Assembly
62
5 Diagnostic
63
Diagnostic on the UDP 56288 10 Port
63
Status of Identity Object, with Explicit Messaging
64
Status in Implicit Messaging
64
Indicators
64
Using Web Server for Diagnostic
65
6 Digital Inputs/Outputs
66
Digital Output (DO)
66
Digital Output Diagnostic
66
Digital Input (DI)
67
7 Ip Address Configuration
68
Configuration Via the DCP Protocol
68
Applying a Default IP Address Using a DIP Switch
69
IP Configuration Via WEB Server
70
Configuration Via the Ethernet/Ip™ 0Xf5 TCP/IP Object
72
8 Web Server
73
Configuration Web Page
73
Account Management on the Web Server
74
System Information Menu
75
Network Settings Menu
76
SNMP Information Menu
76
Ethernet Statistics Menu
77
Ethernet/Ip™ ADAPTER Menu
80
MODBUS Menu
81
File System Menu
82
Firmware Upload Menu
83
Reboot Menu
84
Passwords Menu
84
Logout Menu
85
9 Ftp Server
86
10 Snmp Agent
88
11 Appendices
90
APPENDIX A: MODBUS Frame Formats
90
Appendix B: Mib2
102
Procentec VPGate Manual (104 pages)
PROFINET to Serial
Brand:
Procentec
| Category:
Media Converter
| Size: 4 MB
Table of Contents
Table of Contents
2
1 Properties
5
General Properties
5
Electrical Properties
7
Mechanical Properties
8
2 Hardware Installation
9
Connector Technology
9
Power Connector
9
SERIAL Connector
9
ETHERNET Ports, 10/100 Mbps
10
Digital Input
10
Digital Output
10
Front Panel Indicators
11
DIP Switches
11
Default Configuration
11
Selecting the RS-232/RS-485 Modes
12
Termination Resistance
13
3 Software Configuration
14
Configuration Tools of the PROFINET IO Controller
14
Integrating Vpgate into a Project
14
Importing a GSDML File into the Engineering Tool
14
Integrating Vpgate
14
General Configuration of Vpgate
16
General Parameters
16
Configuration in TRANSPARENT Mode
18
Inserting and Configuring Modules in the TRANSPARENT Mode
21
Configuration in MODBUS Master Mode
24
Inserting and Configuring Modules in the MODBUS Master Mode
25
Behaviour of the MODBUS Master According to PROFINET Status
29
Configuration in the MODBUS Slave Mode
30
Inserting and Configuring Modules in the MODBUS Slave Mode
32
4 Diagnostic
34
Diagnostic on the UDP 5628810 Port
34
PROFINET Diagnostic
35
Diagnostic Digital Output
36
5 Digital Inputs/Outputs
38
Digital Output
38
Digital Input
38
6 IP Address Configuration
40
Configuration Via the DCP Protocol
40
Default Configuration
41
7 MRP Redundancy
43
Functioning in the MRP Client
43
Configuration
43
8 Modbus/Tcp
44
Operating Principle
44
Fault Management
45
MODBUS/TCP GATEWAY to MODBUS SERIAL Mode
45
Operating Principle
45
Fault Management
46
9 Web Server
47
Configuration Web Page
47
Account Management on the Web Server
48
System Information Menu
49
Network Settings Menu
49
SNMP Information Menu
50
Ethernet Statistics Menu
50
PROFINET Menu
53
MODBUS Menu
54
File System Menu
55
Firmware Upload Menu
56
Reboot Menu
57
Passwords Menu
57
Logout Menu
58
Customized WEB
58
Accessing Data Via Personalised WEB
58
An Example of Customised WEB
59
10 Ftp Server
61
11 SNMP Agent
62
12 Appendices
64
13 Other PROCENTEC Products
95
14 Sales Offices and Distributors
97
15 About PROCENTEC
102
16 Notes
103
Advertisement
Procentec VPGate Manual (82 pages)
PROFIBUS to Serial
Brand:
Procentec
| Category:
Gateway
| Size: 1 MB
Table of Contents
Important Information
2
Table of Contents
3
1 Technical Specifications
5
General Characteristics
5
Electrical Characteristics
7
Mechanical Characteristics
7
2 Hardware Setup
8
Connectors Pin out
8
Power Connector
8
SERIAL Connector
8
Digital Input
9
Digital Output
9
Front Panel Indicators
10
DIP Switches
10
Selecting the RS-232/RS-485 Modes
10
Termination Resistance
11
Selection of the PROFIBUS Address
12
3 Software Setup for PROFIBUS DPV0
13
Configuration Tool for PROFIBUS DP Master DPV0
13
Include Vpgate into a Project
13
Import the Vpgate GSD File into the Third Party Configuration Tool
13
Insert Vpgate into the Network Configuration
14
Vpgate Parameters
14
General Parameters
14
Setup Vpgate in TRANSPARENT Mode
16
Setup Vpgate as MODBUS Master
18
Generic Master Mode: PASS-FRAME Function
23
Setup Vpgate as MODBUS Slave
24
Insertion of Input / Output Modules
25
When Vpgate Is in TRANSPARENT Mode
25
When Vpgate Is in Master MODBUS Mode
28
When Vpgate Is in MODBUS Slave Mode
29
4 Fail Safe Mode
31
5 DPV1 PROFIBUS Acyclic Functionalities
32
Configuration Tools of the PROFIBUS DPV1 Master
32
Identification Informations
32
Acyclic Communication in "MODBUS Master" Mode
33
Description of the Index 0 "COMMAND
34
Description of the Index 1 "STATUS
34
Description of the Index 2 "ADDRESS
35
Description of the Index 3 "FUNCTION
35
Description of the Index 4 "OFFSET
36
Description of the Index 5 "LENGTH
36
Description of the Index 6 "DATA
36
Example
36
6 Digital I/O's
38
Digital Output
38
Digital Input
38
7 Diagnostic
40
PROFIBUS Extended Diagnostic
40
Digital Output for Diagnostic
42
8 Firmware Update
43
9 Appendices
44
Appendix A: List of Errors Sent by Vpgate
44
Appendix B: Format of MODBUS Messages
49
10 Other PROCENTEC Products
71
11 Sales Offices and Distributors
73
12 About PROCENTEC
78
13 Notes
79
Advertisement
Related Products
Procentec Categories
Measuring Instruments
Switch
Gateway
Network Accessory
Cable Tester
More Procentec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL