Sign In
Upload
Manuals
Brands
Powell Manuals
Circuit breakers
PowlVac ARG 4 Series
User Manuals: Powell PowlVac ARG 4 Series Breaker
Manuals and User Guides for Powell PowlVac ARG 4 Series Breaker. We have
2
Powell PowlVac ARG 4 Series Breaker manuals available for free PDF download: Instruction Bulletin
Powell PowlVac ARG 4 Series Instruction Bulletin (71 pages)
Vacuum Circuit Breakers
Brand:
Powell
| Category:
Circuit breakers
| Size: 4 MB
Table of Contents
Table of Contents
5
Ch 1 General Information
11
S Cope
12
P Urpose
12
I Nstruction B Ulletins a Vailable E Lectronically
13
Associated B Ulletins
13
Ch 2 Safety
14
S Afe W Ork C Ondition
14
S Afety G Uidelines
15
G Eneral
16
S Pecific
16
X-R Ays
17
S Afety L Abels
17
Ch 3 Equipment Description
18
G Eneral
18
T He S Tored E Nergy M Echanism
18
Mechanical Description
18
Figure 1 Powlvac® ARG & ARM Series 4 Circuit Breaker Front View with Cover
19
Figure 3 Powlvac ARG & ARM Series 4 Circuit Breaker Rear View
21
Figure 4 Primary Current Closeups
22
Figure 5 Cam and Fundamental Linkage Positions
24
Figure 6 Mechanism and Trip Linkages
25
Figure 7 Operation Sequence
27
Figure 8 Typical Control Scheme
28
Electrical Description
29
A Utomatic R Acking M Echanism
30
Breaker Position Indicator
30
Interlocking
30
Blocking Interlock
31
Racking Mechanism
31
Ircuit Reaker Ompartment Nterfaces
32
Primary Disconnecting Devices
32
Secondary Disconnecting Devices
32
MOC (Mechanism Operated Cell Switch) Actuator
32
TOC (Truck Operated Cell Switch) Actuator
32
Ground Connection
32
Shutter Rollers
33
Anti-Rollout Latch
33
Acuum I Nterrupters
33
Acuum I Nterrupter C Onnection
33
25Ka, 36Ka, & 50Ka Rated Circuit Breakers
33
63Ka Rated Circuit Breakers
33
Ch 4 Installation
34
R Eceiving
34
Figure 9 Circuit Breaker in Shipping Carton
34
Figure 10 Circuit Breaker with Shipping Bracket
34
Andling
35
S Torage
35
Figure 11 Circuit Breaker on Crane
35
P Lacing the C Ircuit B Reaker I Nto S Ervice
36
High Voltage Insulation Integrity
36
Table a Field Dielectric Test Values
37
Vacuum Integrity
38
Control Voltage Insulation Integrity
39
Mechanical Operation Check
39
Electrical Operation Check
40
Figure 12 Secondary Disconnect Override Device
40
I Nserting the Ircuit Reaker Nto the Ircuit Reaker Ompartment
41
Prior to Inserting the Circuit Breaker into the Circuit Breaker Compartment
42
Test/Disconnected Position
43
Inserting the Circuit Breaker to the Connected Position
44
Emergency Racking in Procedure
44
R Emoving the C Ircuit B Reaker F Rom the C Ircuit B Reaker C Ompartment
45
Removing the Circuit Breaker from the Connected to the Test/Disconnected Position
45
Test/Disconnected Position out of the Circuit Breaker Compartment
46
Figure 13 Removing Circuit Breaker from Compartment
46
Emergency Racking out Procedure
47
Ch 5 Maintenance
48
G Eneral D Escription
48
Introduction
48
Inspection and Cleaning
49
M Echanism a Rea
49
Mechanical Operation
49
Lubrication
50
Figure 14 Lubrication (50Ka Shown)
52
Figure 15 Lubrication (50Ka Shown) (Cont.)
53
Closing Spring Removal
54
Figure 16 Main Closing Spring Assembly Compressed for Removal
54
Figure 17 Main Closing Spring Assembly Installed
54
Slow Closing of Mechanism
55
Mechanism Adjustments
55
Figure 18 Primary Trip Prop Adjustment
56
Figure 19 Feeler Gauge
57
Figure 20 Latch Check Switch Adjustment
58
Electrical Operation
60
Acuum I Nterrupter and C Ontact a Rea
60
Vacuum Interrupter and Contact Erosion
60
Vacuum Integrity
60
Mechanical Adjustment of Vacuum Interrupters
60
O Ptional Maintenance P Rocedures
60
High Potential Tests
60
Timing
61
Primary Resistance Check
61
Table C Timing
61
Table D Primary Resistance
61
Ch 6 Recommended Renewal Parts and Replacement Procedures
62
O Rdering I Nstructions
62
R Ecommended R Enewal P Arts
62
R Eplacement P Rocedures
62
Vacuum Interrupter Assembly
63
Sliding Contact Finger Assembly (for Circuit Breaker Rated up to 50Ka Only)
63
Closing Coil Assembly
63
Primary Shunt Trip Coil Assembly
63
Secondary Shunt Trip Coil Assembly
63
Undervoltage Device Assembly (UV)
63
Charging Motor Assembly
63
Anti-Pump Relay Assembly
64
Latch Check Switch
64
Motor Cutoff Switch Assembly
64
Auxiliary Switch
64
Ground Connection Assembly
64
Racking Motor
64
Table E Primary Current Path
65
Figure 21 Primary Current Path
66
Table F Control Devices
67
Figure 22 Control Devices
68
Table G Miscellaneous Parts
69
Table H Miscellaneous Parts (Cont.)
70
Advertisement
Powell PowlVac ARG 4 Series Instruction Bulletin (52 pages)
Brand:
Powell
| Category:
Circuit breakers
| Size: 2 MB
Table of Contents
Table of Contents
5
Ch 1 General Information
9
S Cope
10
P Urpose
10
I Nstruction B Ulletins a Vailable E Lectronically
10
Ch 2 Safety
11
S Afe W Ork C Ondition
11
S Afety G Uidelines
12
G Eneral
12
S Pecific
13
S Afety L Abels
14
Ch 3 Equipment Description
15
G Eneral
15
Ating
15
P Rimary D Isconnect S Tabss
15
G Round M Aking Switch
15
S Tored E Nergy M Echanism
16
Figure 1 Ground and Test Device with Probes
17
Figure
17
Figure 2 Ground and Test Device Right View
18
Figure 3 Mechanism - Top View
20
Figure 4 Mechanism - Left View
21
Figure 5 Mechanism and Trip Linkages
22
Figure 6 Cam and Fundamental Link Positions
23
T Est P Orts
24
L Evering
24
Figure 7 Test Ports
24
I Nterlocking
25
S Hutters
25
O Perating S Olenoids
25
Closing Coil
25
Shunt Trip Coil
25
C Ontrol R Elay
26
T Rip P Addle I Nterlock Switch
26
R Emote C Ontrol B Ox
26
K Ey Ocks
26
Key Lock "K1" (Key KA)
26
Key Lock "K2" (Keys KA and KB)
26
Figure 8 Remote Control Box
26
Typical Control Schemes
27
Key Lock "K3" (Key KB)
28
C Ontrol S Elector Switch
28
Ch 4 Installation
29
R Eceiving
29
Andling
29
Figure 10 Ground and Test Device in Shipping Carton
29
S Torage
30
E Lectrical O Peration C Heck
30
Test the Closing Operation of the Ground and Test Device
30
Test the Opening Operation of the Ground and Test Device
30
I Nserting Round and
31
Inserting Ground and Test Device into Upper Compartment
31
D Evice I Nto Switchgear E Quipment
31
Racking Ground and Test Device to the Connected Position
31
Moving the Ground and Test Device from the Connected Position to the Disconnected Position
32
Removing the Ground and Test Device from the Upper Switchgear Compartment
32
Ch 5 Operating Procedures
33
P Rocedure for a Pplying G Round
33
Figure 11 Control Selector Switch in off Position
34
Figure 12 Connecting Control Box to Ground and Test Device
34
Figure 13 Inserting Secondary Disconnect Plug
34
Figure 14 Control Selector Switch to Close Position
34
Figure 15 Press Close on Control Box
34
P Rocedure for T Esting F Eeder
35
Figure 16 Key KA in Lock K1
35
Figure 17 Inserting Key KA into Lock K2
35
Figure 18 Key KB Becoming Available
35
Figure 19 Inserting Key KB into Key Lock K3
36
Figure 20 Lock K3 with Probes
36
Figure 21 Press Open on Control Box
36
T Esting P Orts
37
Ch 6 Maintenance
38
G Eneral Escription
38
Introduction
38
Inspection and Cleaning
38
M Echanism a Rea
39
Mechanical Operation
39
Lubrication
39
Mechanism Adjustments
39
Figure 22 Lubrication
41
Figure 23 Mechanism Detail - Right Side
42
Electrical Operation
43
G Rounding Switch a Rea
43
Routine Maintenance
43
Moving Contact Adjustments
43
Igh P Otential T Ests
44
High Voltage Insulation Integrity
44
Control Voltage Insulation Integrity
44
Figure 24 Ground Switch Contacts
44
Ch 7 Recommended Renewal Parts and Replacement Procedures
45
O Rdering I Nstructions
45
R Ecommended R Enewal P Arts
45
Table B Recommended Renewal Parts
45
R Eplacement P Rocedures
46
Grounding Switch Movable Contact
46
Grounding Switch Stationary Contacts
46
Closing Coil Assembly
47
Charging Motor Assembly
47
Shunt Trip Coil
48
Control Relay
48
Latch Check Switch
49
Trip Paddle Interlock Switch
49
Motor Cutoff Switch Assembly
50
Auxiliary Switch
50
Primary Contact Spring Assembly
51
Ground Shoe Finger Assembly
51
Advertisement
Related Products
Powell PowlVac ARM 4 Series
Powell PowlVac 38 ARM 3000A 4 Series
Powell AP.CBM.01 IRIMK3
Powell AP.CBM.01 IRIM
Powell AP.CBM.01 EIM
Powell 05PV36ARMM-4
Powell 05PV36ARMX-4
Powell 05PV50ARMM-4
Powell 05PV50ARMX-4
Powell 05PV63ARMM-4
Powell Categories
Indoor Furnishing
Circuit breakers
Industrial Electrical
Switch
Measuring Instruments
More Powell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL