Sign In
Upload
Manuals
Brands
Ponsel Manuals
Measuring Instruments
ACTEON 2030
User Manuals: Ponsel ACTEON 2030 Moisture Meter
Manuals and User Guides for Ponsel ACTEON 2030 Moisture Meter. We have
1
Ponsel ACTEON 2030 Moisture Meter manual available for free PDF download: User Manual
Ponsel ACTEON 2030 User Manual (65 pages)
DO-Temperature
Brand:
Ponsel
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
1 The Measuring System
6
The Basic System
6
An O 2 and Temperature Transmitter
6
DO Sensor
6
Accessories
7
Consumables
7
Accessories for a Tank-Mounted Installation Without Cleaning System
7
Accessories for a Tank-Mounted Installation with Cleaning System
7
Accessories for DO and Temperature Sensor In-Pipe Installation (PONCPC-O2T-P-10 or PONCPC- OXYT-P-10)
8
2 Installation
9
Mounting the ACTEON Transmitter Box
9
Connecting the ACTEON 2030 Transmitter and DO Sensor
9
Figure 1 - Transmitter Mounting Diagram
9
Figure 2 - Installing a Measuring System
9
Acteon 2030 Wiring
10
Tank-Mounting
10
Using the Stand and Protective Hood
10
Figure 3 - Installation with a Connection Box
10
Installing the Sensor with a Sensor-Holder Perch (Elbowed or Straight) and Nozzle (Ref.: PONPPCC-O or PONPPCD-O)
11
Figure 4 - Transmitter Mount and Hood
11
Figure 5 - PVC Elbowed Sensor-Holder Perch
12
Figure 6- Cross Section Diagram of the Sensor Nozzle Without Cleaning System
13
Installing an Elbowed Sensor-Holder Perch (Ref: PONPPCC-CIR) or Straight Sensor-Holder Perch (Ref: PONPPCD-CIR) on QRPM (Ref: PONSPFR and PONSPFR2)
14
Figure 7 - Installing a Perch on a QRPM with One or Two Sliders
14
Installing a DO Sensor Cleaning System
15
Figure 8 - Installing the DO Sensor in the Nozzle with the Cleaning System
15
In-Pipe Installation
16
Figure 9 - Installing a DO Sensor in a Pipe
16
3 Acteon 2010 Transmitter
17
Control Console
17
4 Block Diagram of Acteon 2030 Menus
18
5 The Measurement Window
19
6 Calibrating the Acteon 2030
20
Calibrating the Sensors
20
Two Point DO Sensor Calibration (Complete Calibration)
21
DO Sensor Slope Adjustment
24
Returning to Measurement Theoretical Calibration
26
Two Point Temperature Sensor Calibration (Complete Calibration)
27
Adjusting the Temperature Sensor Slope
30
Returning to Temperature Measurement Theoretical Calibration
32
DO Sensor Calibration Error Message Information
33
Clean Water and Sulphite Calibration Error
33
Calibration Error During Air Exposure
33
Temperature Sensor Calibration Error Message Information
33
0°C Calibration Error
33
Ambient Water Calibration Error
34
7 Viewing Measurement History
35
8 Viewing the Sensor Calibration Report
36
9 Configuring Acteon 2000
37
Configuring Sensor Response Averaging
38
Configuring the Trend Line
39
Configuring the Two 4-20Ma Outputs
40
Adjusting 4-20Ma Output Stop Thresholds
41
Calibrating 4-20Ma Outputs
43
Adjusting Relay Outputs
45
Configuring Relays in Mode 1
45
Configuring Relays in Mode 2
46
Configuring Relays in Mode 3
48
Adjusting Measurement Units
50
Setting the Language
51
Resetting Factory Default Values
52
10 Information Menu
53
11 Adjusting the Acteon 2000 Display Contrast
53
12 Technical Specifications
54
13 Sensors
55
DO Sensor
55
Principle
55
Specifications
55
Figure 10 - OXYT Sensor
56
Maintenance
57
Figure 11 - O2T Sensor
57
Figure 12 - Changing the OXYT Membranes and Electrolyte
59
Figure 13 - Changing the O2T Membranes and Electrolyte
60
Temperature Sensor
61
Maintenance
61
Mechanical Diagram
61
14 Questions & Answers
62
Display Screen Troubleshooting
62
Figure 14 - Resetting ACTEON 2000
62
DO Measurement Troubleshooting
63
15 Appendix
64
Figure 15 - Transmitter Wiring Terminal Layout
64
Advertisement
Advertisement
Related Products
Ponsel ACTEON 2050
Ponsel ACTEON 2000 Series
Ponsel ACTEON 2020 Redox-Temperature
Ponsel ACTEON 5000
Ponsel ACTEON 2010
Ponsel Categories
Measuring Instruments
Transmitter
More Ponsel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL