Sign In
Upload
Manuals
Brands
ORTEC Manuals
Metal Detector
radEAGLE
ORTEC radEAGLE Manuals
Manuals and User Guides for ORTEC radEAGLE. We have
1
ORTEC radEAGLE manual available for free PDF download: User Manual
ORTEC radEAGLE User Manual (147 pages)
radio-isotope identification device
Brand:
ORTEC
| Category:
Metal Detector
| Size: 25 MB
Table of Contents
Table of Contents
3
1 Welcome
11
Conventions Used in this Document
11
Safety Warnings
11
Instrument Safety
12
Before First Use
12
The Radeagle
13
Detectors
13
Scintillation Detector
13
Geiger-Müller Detector
13
Neutron Detector
14
Overview
14
Annotated Top View of the Radeagle Instrument
14
Rear View of the Radeagle with Open Latch (Standard Housing)
15
Rear View of the Radeagle with Open Battery Compartment (Underwater Housing)
15
Name Plate on the Rear Latch of the Radeagle
15
Hardware Accessories
16
The Radeagle in the Standard Case
16
The Radeagle in an Optional Watertight Case
17
The Radeagle with Accessories
17
Standard (Left) and Optional Watertight Cases for the Radeagle
18
Connectors
19
2 Using the Radeagle
21
The Radeagle Display
21
Anatomy of the Radeagle Display
21
Status Leds
23
Using the Radeagle Keys
23
The Current Functions of Keys Shown Along the Bottom of the Radeagle Display
24
A Menu with the Third Item Accented
25
Cycling Command Pairs
25
Using Command Lists
25
Using Menus
25
Changing Switches
26
Changing Values
26
Changing Values by Choosing from a List
26
Entering the Password
26
After Entering the Password
27
Entering the Password
27
Saving Screenshots
28
Status Bar after Saving a Screenshot
28
Starting up the Radeagle
29
Box with Potassium Chloride (Kcl) for Stabilization and Calibration
29
Starting the Radeagle
29
Switching off the Radeagle
30
Initial Stabilization
30
Initial Stabilization after Identification of the Stabilization Source
30
3 Radeagle Measuring Modes
31
Dose Rate Mode
31
Dose Rate Display
31
Dose Rate Display with Gamma Warning
32
Dose Rate Display with Gamma Alarm
32
Easy ID Mode
33
The Easy ID Screen
33
The Easy ID Results
33
Detect Mode
34
Detect Mode Background Measurement
34
Detect Mode Chart
35
Detect Mode: Approaching a Source
35
Detect Mode: Close to a Source
36
4 Radeagle Warnings and Alarms
37
Gamma Warning and Alarm Display
38
A Warning Reported on Screen
38
An Alarm Reported on Screen
38
An Neutron Alarm Reported on Screen
39
Neutron Alarm Display
39
5 Radeagle Advanced Menu
41
Spectrum
42
The Advanced Operations Menu
42
The Spectrum Screen
43
Result of a Spectrum Analysis
43
Spectrum with Cursor
44
Zoomed Spectrum with Cursor
44
Spectrum with Region of Interest
45
Info about a Saved Spectrum's File Name
45
Spectrum Files Available for Loading
46
Basic Settings
47
The Auto ID Waterfall Display
47
The Basic Settings Menu
47
Time and Date
48
The Clock Settings
48
Display
49
The Display Settings
49
Feedback
50
The Feedback Settings
50
Reachback
51
The Reachback Settings
51
Connectivity
52
Wi-Fi Settings
52
The Connectivity Menu
52
The Wi-Fi Settings
53
Available Wi-Fi Access Points
53
Hotspot Settings
54
Connected to a Wi-Fi Network
54
Hotspot Is off
55
Hotspot: Web Interface Info
55
Bluetooth Settings
56
Hotspot: Access Credentials
56
USB Connections
57
Bluetooth Instructions on a Pristine Radeagle
57
Connect to a Known Bluetooth Device
57
USB Cable Connection Information
58
USB Cable to Host Computer
58
Web Interface Address for Devices Connected Via Bluetooth
58
Data Transfer to a USB Mass Storage Device
59
USB Storage Device
59
Data Transfer Complete
60
Ethernet LAN Connection Information
60
USB Ethernet Adaptor
60
Services
61
The Services Screen
61
Gps
62
The GPS Settings When GPS Is off
62
The GPS Settings Immediately after Switching on GPS
62
Easy Calibration
63
The GPS Settings While Searching Satellites
63
The GPS Settings after Determinig the Location
63
Selecting a Source for Easy Calibration
64
Easy Calibration in Progress
64
Protected Settings
65
Easy Calibration Finished
65
The Protected Settings Menu
65
System Information
66
Alarm Settings
66
The Hardware Status
66
The Alarm Settings
67
Calibration
68
The Calibration Screen
68
The Calibration Screen after Measurement
68
ID Settings
69
Easy ID Settings
69
The ID Settings Menu
69
Nuclide Library
70
The Easy ID Settings
70
The Nuclide Library Ready for Selecting a Nuclide
70
The Nuclide Library with 131 I Selected for Editing Its Category
71
Storage Management
72
The Nuclide Library with 131 I Selected for Editing Its On/Off Property
72
Storage Management: Summary
73
Storage Management: List of Folders with Different Types of Data
73
Storage Management: Commands for a Type of Data
74
Storage Management: List of Files of a Certain Type
74
Set Password
75
Storage Management: Specify Files to be Deleted
75
Setting the Password
75
Factory Settings
76
Collect Reachback
76
Reset to Factory Settings
76
Settings for a New Measurement
77
Collecting Reachback Data
77
Send Data
78
Collected Measurements
78
Checking the Internet Connection
78
No Internet Connection
79
File Types for Mailing
79
Self Test
80
Selecting Files
80
Ready to Send Files
80
The Self Test Screen
80
About
81
Shutdown
82
The Instrument Information
82
Shut down Verification
82
6 Accessing Radeagle Data
83
Storage Management
83
Data Transfer
83
Web Interface
84
Sending Data Via E-Mail
84
The Menu Overlay of the Web Interface
85
The Device Information in the Web Interface
86
The Wi-Fi Hotspot Info in the Web Interface (Off)
86
The Wi-Fi Hotspot Info in the Web Interface (On)
87
The Remote Radeagle's Screen in the Web Interface
88
The Spectrum Browser in the Web Interface
89
Spectrum Diagramm in the Web Interface
90
Zooming into the Spectrum
91
Enlarged Part of the Spectrum
91
Marking a Peak for Analysis
92
Results for a Manually Marked Peak
93
Results of an Automatic Peak Analysis
94
Spectrum with Scaling Methods and Detail Overview
95
Spectrum with Expanded Detail Information
96
Comment Subsection of Spectrum Details
97
PDF Report of a Spectrum
98
The Spectrum File Viewer in the Web Interface
99
The Radeagle Settings in the Web Interface
99
The Reachback Settings in the Web Interface
100
The Expanded Reachback Settings in the Web Interface
101
Adding a Recipient for Reachback Messages
102
Update Software on the Radeagle in the Web Interface
103
Transfer Software to the Radeagle in the Web Interface
103
Ready to Install the Transferred Software
103
Successful Installation of the Software
104
Documents Available on Your Radeagle
104
Managing the Storage in the Web Interface
105
The Standard Black Rechargeable Powercell of the Radeagle
107
The Blue Powercell for Common Batteries
108
The Blue Powercell Filled with Batteries
108
Orientation of AA Bateries in the Blue Powercell (Shown Without Cover)
108
Pulling the Protection of the Power Connector
109
Opening the Rear Latch of the Radeagle
109
Removing the Powercell from the Radeagle
110
Inserting a Powercell
110
Snapping the Powercell into Place
111
The Powercell Correctly Mounted in the Radeagle
111
Powercell in the Radeagle after Removing the Cover
112
Removing the Powercell with Gravity Assistance
112
Correct Placement of the O-Ring Seal on the Inner Side of the Cover Plate
113
Correct Placement of the Battery Cover Plate
113
Inserting the External Power Plug
114
Unplugging the External Power Connection
114
Do NOT Rotate the Connector, Do NOT Bend or Pull at the Power Cable
115
Wall Power Supply with International Adaptors
115
Removing an Adaptor from the Wall Power Supply
116
Mounting an Adaptor to the Wall Power Supply
116
Advertisement
Advertisement
Related Products
ORTEC RADEAGLET
ORTEC Categories
Amplifier
Measuring Instruments
Laboratory Equipment
Control Unit
Security Sensors
More ORTEC Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL