Sign In
Upload
Manuals
Brands
Oridion Manuals
Medical Equipment
Capnostream 20p
Oridion Capnostream 20p Manuals
Manuals and User Guides for Oridion Capnostream 20p. We have
1
Oridion Capnostream 20p manual available for free PDF download: Operator's Manual
Oridion Capnostream 20p Operator's Manual (141 pages)
Brand:
Oridion
| Category:
Medical Equipment
| Size: 8.76 MB
Table of Contents
Table of Contents
3
Microstream Etco 2 Consumables
4
Table 11 - Nellcor Spo
4
List of Figures
10
List of Tables
11
Oridion Medical 1987 Ltd. ("Oridion Medical") - Warranty for Oridion Monitors
12
Safety Information
13
General
13
Warnings
13
Alarms
14
Fire Hazard
14
Monitor Use with Defibrillators
14
MRI Scanning
14
Electrical
15
Electro-Magnetic Interference
15
Definitions
16
Chapter 1 About this Manual
17
Intended Use
17
Overview
17
Contacting Technical Support
18
Specific Indications for Use
18
Symbols
18
Table 1 - Symbols that Appear on the Monitor
18
Who Should Read this Manual
18
Chapter 2 Technology Overview
21
Features
21
What Is Capnography
21
What Is Pulse Oximetry
22
Chapter 3 The Capnostream Monitor
23
Introduction
21
Unpacking and Inspection
23
Screen Timeouts
23
Installing the Battery Pack
24
Handling the Battery Pack
25
Testing the Battery and AC Connections
25
Battery and Power Usage
26
Disposing of the Battery
26
Storing the Battery
26
Accessories
27
Available Accessories
27
Table 2 - Capnostream Accessories
27
Monitor Mounting Plate
28
Printer Paper
28
Mounting the Monitor
27
Setting up Periodic Maintenance
27
Buttons, Indicators and Connections
28
Table 3 - Printer Paper Specifications
28
Monitor Front View
29
Table 4 - Capnostream Front View
29
Front Panel Control Buttons
30
Monitor Rear Panel
31
Table 5 - Capnostream Rear View
31
Monitor Left and Right Views
32
Table 6 - Capnostream Left View
32
Turning on the Monitor
32
Standard Sections of the Display Screen
33
Home Screen Standard Display
34
Table 7 - Header Section
36
Home Screen Numeric Display
38
Screen Navigation
39
Configuration Changes
40
Terminating Operation of the Monitor
39
Setting Date, Time, Language, and Other Options
40
Screen Timeouts
41
Capnostream ® 20 P : Operational Check Sheet
42
Chapter 4 Using the Capnostream Monitor
45
Preparing the Monitor for a Patient
45
Setting the Patient Type
45
Using Patient Cases and Patient ID Numbers
46
Changing the Alarm and Pulse Volumes
48
Alarm Volume
48
Table 8 - Event Markings
48
Alarm Volume Default Options
49
Pulse Tone Volume
49
Table 9 - Audio Alarm Volume
49
Entering Patient Events
48
Alarm Delay
50
Turning the Pump off for Suction or Lavage
50
Use of Scavenging System
50
Demo Mode
51
Monitor Screen Menu Reference Chart
51
Chapter 5 Capnography with the Capnostream Monitor
55
Microstream Etco Consumables
55
Basic Principles
55
Microstream Etco2 Consumables
56
CO 2 Data Displayed by the Capnostream Monitor
56
Connecting a Filterline
56
Adjustable CO
57
Table 10 - Adjustable CO
57
Monitoring CO 2 During MRI Scanning
58
Monitoring CO During MRI Scanning
58
Chapter 6 Pulse Oximetry with the Capnostream Monitor
59
Nellcor Spo Sensors
59
Data Update Period, Data Averaging, and Signal Processing
60
Selecting Nellcor Spo 2 Sensors
60
Performance Considerations
61
Connecting an Spo Sensor to the Monitor
62
Spo 2 Data Displayed by the Capnostream Monitor
62
Adjustable Spo 2 Parameters
64
SPO 2 Alarm Limit Message
64
Table 12 - Adjustable Spo
64
Chapter 7 Integrated Pulmonary Index
65
Introduction
65
IPI Display
66
IPI Options
66
Table 13 - Adjustable IPI Options
66
Warnings
66
Apneas Per Hour
67
The Capnostream Apneas Per Hour
67
A/Hr Visual Alert
68
Chapter 8 Apneas Per Hour and the Oxygen Desaturation Index
67
Introduction
67
Apnea and O2 Desaturation Report
68
Monitoring with A/Hr and ODI
68
Oxygen Desaturation Index (ODI)
68
A/Hr and ODI Demo Mode
69
A/Hr and ODI Option
69
Smart A/Hr and ODI Home Screen Display
69
Chapter 9 Alarms and Messages
71
Introduction
71
Table 14 - Alarm Indications
71
Alarm Display
72
Alarm Delay
74
Message Priorities
74
Types of Alarms
74
High Priority Alarms
75
Table 15 - High Priority Alarms
75
Medium Priority Alarms
76
Table 16 - Medium Priority Alarms
76
Advisories
77
Silent Advisories
77
Table 17 - Advisories
77
Table 18 - Silent Advisories
77
Parameter Standby Mode
78
Alarm Silence
80
Table 19 - Message and Alarm Status During Different Parameter Standby Situations
80
Changing Alarm Limits
81
Spo 2 Alarms and Satseconds
82
Satseconds Alarm Display
83
Testing Alarm Settings
82
Alarm Limits - Factory Defaults
84
Chapter 10 Using Trends
85
Introduction
85
Graphical Trend Display Screen
86
Graphical Trend Display
86
Using SCROLL and ZOOM
87
The Trend Display Screens
86
Tabular Trend Display Screen
89
Table 20 - Tabular Display Example
90
Table 21 - Detailed Tabular Display Example
90
Choosing Trend Parameters
91
Important Notes Regarding Trend Reports
91
Printing the Trend Data
91
Specific Events as Seen in Trend Data
91
Using the Graphical Trend Screen for Monitoring Patients
91
Clearing Trend Memory
92
Configuring Trends
92
Table 22 - Monitor Parameters
92
Event Marking Mode
93
Trend Graphical Display
93
Trend Increment Display
93
Chapter 11 Reports
95
Apnea and O Desaturation Report
95
Printed Report Options
99
Printed Reports
99
Table 23 - Printed Reports - Parameters
100
Sample Reports
103
Sample Case Reports
103
Sample Trend Reports
104
Chapter 12 Downloading Patient Data
105
Data Transfer Via the USB Data Port
105
Introduction
105
Table 24 - Data Transfer Types
105
Table 25 - Select Data Output Type
107
Examples
108
Table 26 - File Naming Conventions
108
USB File Naming Convention
108
Reading Patient Data from Saved Capnostream Files
109
USB Error Messages
109
Analog Data Output with Capnostream
109
Data Transfer Via the RS-232 Port
109
Nurse Call Operation
109
Types of Nurse Call Systems
110
Table 27 - Nurse Call Specs
110
The Nurse Call Cable
110
Activating Nurse Call
111
Table 28 - Nurse Call Indicators
111
Testing Nurse Call
111
Operation with Hospital Patient Data Systems
112
Operation with Nuvon VEGA Systems
112
Chapter 13 Maintenance and Troubleshooting
113
Determining Monitor Service Hours
113
Introduction
113
CO 2 Calibration
114
CO 2 Calibration Check
115
Calibration Check Procedure
115
Maintenance
116
Replacing the Fuses
116
Cleaning
117
Replacing the Printer Paper Roll
117
Troubleshooting
118
CO 2 Problems
118
Electrical
118
Printer
119
Spo 2 Sensor
119
CO 2 Calibration
120
Nurse Call
120
Returning the Monitor
120
Technical Assistance
120
Appendix 1
121
Institutional Settings
121
Changing Institutional Defaults
121
Institutional Defaults
121
Resetting to Factory Defaults
122
Uploading or Downloading Institutional Defaults
122
Alarm Limits
123
Changing Monitor Settings
123
Table 29 - Factory Default Alarm/Indicator Limits
124
Alarm Delay
125
Changing Parameters Order on the Trend Display
125
Table 30 - Factory Default and Optional Alarm Delay Settings
125
Table 31 - Factory Default and Optional Trend Settings
125
Trend Settings
125
Events
126
How to Change Event Defaults
126
Monitor Settings
126
CO 2 Parameters
128
Spo 2 Parameters
128
Appendix 2
129
Specifications
129
Battery
129
Controls
129
Power Supply
129
Display
130
Microstream ® Capnography
130
Alarms
131
Analog Output
131
Nellcor Oximax ® Pulse Oximetry
131
Outputs
131
Nurse Call
132
Internal Thermal Printer (Optional)
133
Rs-232
133
Usb
133
Compliance
134
Electromagnetic Immunity
134
Equipment Classification
134
General Characteristics
134
Table 32 - Guidance and Manufacturer's Declaration - Electromagnetic Emissions
135
Table 33 - Guidance and Manufacturer's Declaration - Electromagnetic Immunity
135
Table 34 - Recommended Separation Distances between Portable and Mobile RF Communications Equipment and the Monitor
137
Appendix 3
139
Microstream Etco 2 Consumables
139
Advertisement
Advertisement
Related Products
Oridion Microstream FilterLine XL
Oridion Microstream Smart CapnoLine Guardian
Oridion Smart OmniLine Guardian
Oridion Smart SureLine Guardian
Oridion Sure VentLine H Set
Oridion Sure VentLine Set
Oridion Categories
Medical Equipment
More Oridion Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL