Sign In
Upload
Manuals
Brands
Nipro Manuals
Medical Equipment
SURDIAL
User Manuals: Nipro SURDIAL Hemodialysis Machine
Manuals and User Guides for Nipro SURDIAL Hemodialysis Machine. We have
2
Nipro SURDIAL Hemodialysis Machine manuals available for free PDF download: Service Manual, Operation Manuals
Nipro SURDIAL Service Manual (335 pages)
SINGLE PATIENT DIALYSIS MACHINE
Brand:
Nipro
| Category:
Medical Equipment
| Size: 5 MB
Table of Contents
Safety Precautions
5
Table of Contents
9
1 Application
17
2 Contraindication
19
3 Precautions
21
4 Symbol for Safety
23
5 Flow Chart
25
Fluid and Blood Lines
27
Flow Chart
27
List of Input Components
29
List of Output Components
30
List of Other Components
31
6 Disassembling and Replacement
33
Input Components
35
A Type
35
Conductivity Cell Assy (CD)
35
B Type
36
C Type
37
D Type
38
Conductivity Cell Assy and Temperature Sensor Assy
39
Dialysate Pressure Sensor Assy (PD)
41
Dialysate Pressure Sensor Assy (TYPE I)
41
Dialysate Pressure Assy (TYPE II: a Type)
42
Dialysate Pressure Assy (TYPE II: B Type)
43
Blood Leak Sensor Assy (BLD)
45
Blood Leak Sensor Assy (TYPE I: RK-GR1)
45
Blood Leak Sensor Assy (TYPE II: RK-GR2)
46
Blood Leak Sensor Assy (TYPE II: BLD-01)
47
Pressure SW: AW-3200-63-A (PS)
49
Temperature Sensor Assy (T)
51
Pt-Hst-1000
51
Pt100-Hsta-900
52
Air Bubble Detector Assy (BD)
53
Output Components
55
Av-3202-318-Sc (V2/V3/V12/V13/V14 (V17))
55
Two Way Electromagnetic Valve
55
Type I: Av-3202-63-S (V4/V11)
57
Type II: Svb-2B
58
Type II: Sv2-322-S
59
A Type: AV-3202-63-SH
61
B Type: SAV-3202-33-SB
62
C Type: SV2-322-S
63
Three Way Electromagnetic Valve: AV-3302-63-S (V5/V6/V7/V8/V9)
65
Bellowphragm Pump: VCP-60 (Vpa / Vpb)
67
Sensor Guide Rod: Pin Type 1
67
Sensor Guide Rod: Plane Type
68
Sensor Guide Rod: Pin Type 2
69
Sensor Guide Rod: Pin Type 3
70
Compatibility
71
Distinction of VP Type
71
Distinction Type of VP by Serial Number of Machine
71
Reference for Bellowphragm Pump
71
Blood Pump Assy (BP / BPC)
73
M3 Type
74
M4 Type
75
Gear Pump Assy (P1/P2)
77
TYPE I: Micro Gear Pump
77
TYPE II: Magnet Gear Pump (Normal Type)
79
TYPE II: Magnet Gear Pump (a Type)
81
How to Verify the Type of Magnet Gear Pump
83
Maintenance
83
Reference for Gear Pump
83
Serial Numbers
83
Venous Clamp Assy (CLV)
85
Syringe Pump Assy (SP)
87
Other Components
89
Deaeration Tank Assy (AS1)
89
A Type
89
Deaeration Tank Assy (B Type)
90
Deaeration Tank Assy (AS2)
91
Buffer Tank W Assy (BTW)
93
Buffer Tank D Assy (BTD1 / BTD2)
95
Check Valve (C1/C2)
97
#919342300041(Ac-2200-55-S) (C1)
97
Dialysate Check Valve (C1)
97
Ac-2200-53-S (C2)
98
Bellowphragm Check Valve (C2)
98
Ac-4200-53-A (C2)
99
GVS Filter
101
PP Body Type
101
Supply Water Filter (F)
101
Coupler Line Filter (F7)
102
A Type
103
Flow Meter Assy (FM / FS)
103
B Type
104
C Type
105
Reducing Valve Assy (PR)
107
Er0883Zss8/Rw83
107
Er0884Zbs8
108
Relief Valve (RV1/RV2/RV3/RV4)
109
Relief Valve 3: AC-3200-63H-T (RV3)
110
Ac-4200-53-S (Rv4)
111
Relief Valve 4 (AC-4200-53-S)
111
Ac-4200-53-Sa (Rv4)
112
Sampling Port Assy (SL)
113
Chamber Assy (Vca / Vcb)
115
Chamber Assy (Overall)
115
Chamber Assy (Viscous Chamber)
117
Concentrate Tank Connectors
119
Black Socket Type
119
Concentrate Tank Connector (for a and B Concentrates)
119
Red/ Blue Socket Type (Separated Hose Port Type)
120
Red/ Blue Socket Type (One-Piece Hose Port Type)
121
Concentrate Tank Connector (for Disinfectant Concentrate)
122
Rinse Port No.1 (for a and B Concentrates)
123
Rinse Port No.2 (for a and B Concentrates)
124
Rinse Port No.3 (for a and B Concentrates)
125
Rinse Port (for Disinfectant Concentrate)
126
Coupler Assy
127
Coupler Assy (a Type)
127
Coupler Assy (B Type)
128
Needle Valve (NV1 / NV2)
129
Am-1200-55A
129
Sas-08001
130
Piping Parts
131
7 Construction of Electrical Part
133
Components of Electrical Part
135
Components at Upper Part of Electrical Part
135
Component at Lower Part of Electrical Part
135
Placement of Electrical Part at Machine
136
Type I
136
TYPE II Placement of Electrical Part
137
Components at Left Side in Electrical POWER BOX
138
Components at Right Side in Electrical POWER BOX
139
Connection, Replacement and Adjustment
141
Operation Panel Sheet
143
General Description and Application
143
Disconnection of Flexible Cord
144
Operation Panel Board
145
LCD Module
147
Bubble Sensor Board
149
SBY0160 Board
149
SBY0205 Board
150
Bubble Sensor Board (SBY0205)
150
Dialysate Pressure Sensor Board
151
Type I
151
Dialysate Pressure Sensor Board (TYPE II: a Type)
153
Dialysate Pressure Sensor Board (TYPE II: B Type)
154
Main Board
155
The Way of Distinction Board
157
Attachment of ROM
158
Venous and Arterial Pressure Sensor Boards
159
DSUB Board
161
Buzzer Board: SBY0162 Board / SBY0267 Board
163
Sub-Board
165
SBY0157 Board / SBY0163 Board
165
Two Types of Sub-Board
167
Fuse
168
SBY0270 Board
169
DC+5V, ±12V Power Supply
173
DC+5V, ±12V Switching Regulator
173
Swt30-522
173
SWT30-522Kai
173
Distinction of Switching Regulator
174
DC+5V, ±12V Switching Regulator (LDC30F-1-G/LDC30F-1-Gkai)
175
Ldc30F-1-G
175
LDC30F-1-Gkai
175
DC+5V, ±12V Converter Board SBY0254
177
DC+24V Switching Regulator
179
Pley24Hsz-C
179
Switching Input Voltage
181
Zws150Paf-24/J
182
DC+24V Switching Regulator (ZWS150PAF-24/J)
182
Cme150-24
184
Operation Panel Board, Main Board, Sub-Board
187
Distinction Among Connectors
187
Distinction Among Operation Panel Boards
188
Distinction Among Main Boards
188
Distinction Among Sub Boards
189
Connection of Harness and Board
190
VR Board: SBY0268 Board
191
Fuse
193
Fuse Holder
194
9 Maintenance Modes
195
Maintenance Modes
195
Display
197
Screen Flow
197
Maintenance Modes
199
ROM before Ver.2.40
199
ROM after Ver.3.00
201
Maintenance Mode Menu Screen
203
Maintenance Mode 1 Screen
205
ROM before Ver.2.40
205
ROM after Ver.3.00
206
Maintenance Mode 2 Screen
207
Maintenance Mode 3 Screen
209
Maintenance Mode 4 Screen
211
Maintenance Mode 5 Screen
213
When Dialysis Mode BC1 or BC2 Is Set
213
When Dialysis Mode AC Is Set
214
Maintenance Mode 6 Screen
215
ROM before Ver.3.70
216
ROM after Ver.3.84
218
Maintenance Mode 7 Screen
221
ROM before Ver.2.40
222
ROM after Ver.3.00
223
Maintenance Mode 8 Screen
225
ROM before Ver.2.40
226
Input Screen
227
Monitor Screen
227
Zero Cleared Screen
227
ROM after Ver.3.00
227
Maintenance Mode 9 Screen
229
Maintenance Mode 10 Screen
231
10 Adjustment
233
Measurement of Chamber Capacity and Adjustment of Silicone Volume
235
Adjustment of Silicone Oil Volume
237
Adjustment of Venous and Arterial Pressure Sensors
239
Adjustment of Arterial Pressure Sensor (Option)
240
Adjustment Dialysate Pressure Sensor
241
Type I
241
Adjustment of Dialysate Pressure Sensor
242
Adjustment Dialysate Pressure Sensor
243
Dialysate Pressure Assy
243
Adjustment of PD Offset
245
Adjustment of Temperature Sensor
247
Connection to Resistor for Calibration
247
Main Board and Terminal Bed TM1
247
Adjustment of Pressure SW
249
Adjustment of Blood Leak Sensor
251
Type I: Rk-Gr1
251
Type II: Rk-Gr2
253
Zero Revision of Blood Leak Detector
253
Check of Accuracy of Blood Leak Sensor Using Pseudo Filter
254
Pseudo Filter
254
Removed Method of Cartridge
254
Type II: Bld-01
255
Blood Leak Sensor BLD-01 Front View
255
Zero Offset of Blood Leak Sensor
255
Checking through Pseudo Blood Leak Filter
256
Dismounting of Cartridge
256
Outline of Cartridge
256
Adjustment of Blood Leak Sensor
257
Adjustment of Reducing Valve
259
Connection of Reducing Valve to Manometer
259
Adjustment of Priming End Pressure
261
Connection of Manometer
261
Adjustment of Closed Circuit Pressure
263
Adjustment of Priming Flow Rate
265
Adjustment by Flow Meter
265
Adjustment by Discharge Flow Time
266
Adjustment of Bypass Flow Rate
269
Correct and Incorrect Conditions of Pinch Cock 1 (PC1)
269
Adjustment by Water Head Pressure
271
Adjustment of Gaps between Housing and Rotor Rollers of Blood Pump
271
Adjustment Using Syringe and Manometer
272
Adjustment of Blood Pump Flow Rate
273
In Case of You Use Standard Rolling Tube (Φ8×Φ12Mm)
273
In Case of You Use Small Rolling Tube (Φ6.35×Φ9.75Mm)
274
Leak Test and Gap Adjustment of Clamp
275
Leak Test of Clamp
275
Test Setup for Clamp Leak Test
275
Gap Adjustment of Clamp
276
Adjustment of Bubble Sensor
277
SBY0160 Board
277
SBY0205 Board
278
Adjustment of Output Level
279
Adjustment of Conductivity and Concentration
281
Adjusting and Calibrating Process
281
Selection of Dialysis Mode to be Adjusted
282
Input of Concentration Data
283
Input of Data of Acetate Concentrate
284
Adjustment of Dilution Ratio
285
Adjustment of Dilution Ratio of Bicarbonate B Concentrate
286
Adjustment of Dilution Ratio of Acetate Concentrate
287
Calibration of Indicated Conductivity and Concentration
288
Adjustment of Contrast
289
Adjustment of Gas Purge Pressure
291
Adjustment of Pinch Cock
291
Adjustment of Flashing Volume in Concentrate Line
293
Confirmation of Flushing Volume
293
Adjustment of Flushing Volume
294
Adjustment of Priming Volume in Concentrate Line
295
Confirmation of Priming Volume
295
Adjustment of Priming Volume
296
Adjustment of Syringe Pump Infusion Flow
297
Adjustment of Overload Detection on Syringe Pump Assy When Other than Nipro Syringe Used
299
Adjustment of Conductivity Sensor
301
11 Dip Switches
303
Operation of Dip Sw's
305
Main Board and Dip Sw’s
305
Functions of Dip Sw's
307
Dip SW2
307
Dip SW3
307
ROM before Ver.2.40
307
ROM after Ver.3.00
308
ROM after Ver.3.93
309
ROM after Ver.4.41
310
12 Various Data
313
Loaded CPU and ROM
315
Wiring in POWER Box
317
Electrical Power Box
317
Distinction Among Electrical Power Boxes
317
Wiring in POWER BOX a Type
319
Wiring in POWER BOX B Type
320
Wiring in POWER BOX C Type
321
Wiring in POWER BOX D Type
322
Record Sheet of Setting Value
323
ROM before Ver.2.40
324
ROM after Ver.3.00
326
ROM after Ver.3.30
328
ROM after Ver.3.84
330
ROM after Ver.4.41
332
Advertisement
Nipro SURDIAL Operation Manuals (198 pages)
SINGLE PATIENT DIALYSIS MACHINE
Brand:
Nipro
| Category:
Medical Equipment
| Size: 3 MB
Table of Contents
Table of Contents
4
Cautions for Safety ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Caution-1~6
14
1 Intended Use
20
2 Contraindication
20
3 Cautions ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 3-1~2
21
4 Definitions
23
6 Installation
28
Installation Environment
28
Ambient Conditions
28
Power Supply
28
When Machine Power Rating Is AC 230V
28
Necessary Space Requirements to Use the Machine
29
Water Supply and Drainage Conditions
29
Water Quality
29
Water Supply Flow Rate
29
Water Supply Pressure
29
Water Supply Temperature
29
Concentrate Line Pressure
30
Drainage
30
Unpacking and Check of Contents
31
Procedure for Assembling
33
Cautions
33
Attachment of I.V. Pole, Hanger and Main Lamp
33
Connector for each Concentrate Container
34
Procedures for Tube and Plug Connections
35
Connections of Fluid Supply and Drain Lines, Coupler and Power Plug
35
Connection of Dialysate Coupler Tubes
35
Connection of Power Plug
35
Connection of Water Supply Port
35
Connections of Drain Port of Machine Side
35
Connection of each Concentrate
36
Connection for Disinfection
36
Connection for Water Rinsing
36
Connection to Execute Dialysis Operation(before Blood Line Connection)
36
Connection for Acetic Acid Rinsing (When Acid Rinse Option Is Not Used)
37
Connection for Acetic Acid Rinsing (When Acid Rinse Option Is Used)
37
Connection for Automatic Rinsing (1 or 2)(When Acid Rinse Option Is Used)
37
Air Purge
38
Disinfection of the Dialysate Circuit
39
Disposal of Used Machine
39
Disposal of Used Packaging Materials
39
Disposal of Blood Lines and Dialyzer
39
7 Main Functions and Components ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 7-1~2
40
8 Construction of Machine ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 8-1~14
41
Overall Construction
41
Overall Views
41
Components of Machine and Their Purposes and Functions
43
Operation Panel
45
Construction of Operation Panel
45
Components of Operation Panel and Their Purposes and Functions
46
Blood Line Setting Panel
49
Construction of Blood Line Setting Panel
49
Components of Blood Line Setting Panel and Their Purposes and Functions
50
Power Box
52
Main Lamp Assembly
53
Construction of Main Lamp Assembly
53
Components of Main Lamp Assembly and Their Purposes and Functions
54
9 Display
55
Layout of Display
57
Wake up Screen
60
Rinse Screen
61
Rinse Menu
61
Rinse Wait
62
Rinse1: Water
62
Rinse2:Chemical
62
Rnse3:Auto1 C&D
62
Rinse4: Auto2 C&D
63
Rinse Execution
64
Rinse1: Water
64
Rinse2: Chemical
64
Rinse3: Auto1 C&D
64
Rinse4: Auto2 C&D
64
Rinse End
66
Rinse1: Water
66
Rinse2:Chemical
66
Rinse3:Auto1 C&D
66
Rinse4:Auto2 C&D
66
Dialysis Screen
67
Dialysis
67
Priming
68
Test Mode
69
Settingⅰ Screen
70
Settingⅱ Screen
71
Maintenance Menu Screen
72
Alarm Screen
73
10 Alarm Functions and Resetting
74
Description of Alarms
74
Functions When Error Is Alerted
74
Procedure for Resetting
75
Actions to Respond to Alarm (Flow)
75
Table of Alarms
76
Meanings of Terms Contained in "Table of Alarms
76
Table of Alarms ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 10-3~14
78
11 Cleaning and Disinfection
89
Cleaning and Disinfection of Machine Outside
89
Machine Enclosure
89
Dialysate Concentrate Connectors and Rinse Ports
89
Cleaning and Disinfection of Fluid Lines
89
Disinfection of Fluid Line Inside
90
Concentration of Disinfectant Concentrate
90
Diluted Disinfectant Concentration and Disinfection Time
90
Method to Set Dilution Rate of Disinfectant Concentrate
91
Check of Residual Disinfectant
91
Removal of Calcium Deposit from Fluid Line Inside
92
Concentration of Acetic Acid Concentrate
92
Diluted Disinfectant Concentration and Disinfection Time
92
Concentration of Acetic Acid to be Diluted
92
Method to Set Dilution Rate of Acetic Acid Concentrate
93
Check of Residual Acetic Acid
93
12 Process Flow
94
Description of Process Flow
95
Rinse Wait Process
95
Rinse Process
95
Acid Rinse Mode
95
Disinfection/Rinse Mode
95
Dwelling Mode
95
Prerinse Mode
95
Water Rinse Mode
95
Rinse End Process
96
Dialysis Wait Process
96
Preparation Process
96
Preparation End Process
96
Dialysis Process
96
Recovery Process
96
Air Purge Process
96
13 Operation of Machine
97
Check and Action before Turning on Power Breaker
97
Procedures for Machine Operation
100
Machine SW on
100
Prerinse
100
Dialysis
101
Postrinse
101
Machine Power Breaker off
101
14 Rinsing
102
Selection of Rinsing Mode
103
Setting of Rinsing Pattern (Example: RINSE4 (AUTO2 C&D)
103
Connection of Concentrates
104
Connection of Concentrates When Acid Rinse Port (Option) Is Not Used
104
Connection at Acid Rinse
104
Connection at Disinfection/Rinse
104
Connection at Water Rinse
104
Connection of Concentrates When Acid Port Unit (Option) Is Used
105
Connection at Acid Rinse
105
Connection at Auto Rinse 1 or
105
Connection at Disinfection/Rinse
105
Connection at Water Rinse
105
Start of Rinsing (Example: RINSE4(AUTO2 C&D)
106
Completion of Rinsing
106
Discontinuance of Rinsing
107
15 Double Needle Dialysis
108
Setting of Dialysate Related Parameters
109
Setting of Dialysis Mode
109
Setting of Dialysate Concentration
109
Bicarbonate Dialysate
109
Acetate Dialysate
110
Setting of Dialysate Temperature
110
Connection of Concentrates
111
Connection of Concentrates to Prepare Bicarbonate Dialysate
111
Connection of Concentrate to Prepare Acetate Dialysate
111
Setting of Blood Line, Dialyzer and Syringe
112
Setting of Blood Line
112
Setting of Dialyzer
112
Setting of Syringe
112
Setting of Syringe Pump
112
Setting of Cross-Section Ratio of Syringe
112
Setting of Fast-Forward Volume
114
Setting of Syringe Operation Stop Time
114
Preparation of Machine (Preparation Process)
116
Check of Preparation Completion of Machine (Preparation End Process)
116
Priming Process
117
Setting of Saline Vial
117
Priming of Saline
117
Priming of Dialyzer with Dialysate
118
Rinsing of Blood Line and Dialyzer
118
When Priming Function Is Used
118
When Priming Function Is Not Used
119
Check of Dialysate Conductivity
120
Setting of UF Related Parameters
120
Connection of Patient
121
Start of Dialysis (Dialysis Process)
122
Start of Dialysis
122
Setting of Upper and Lower Venous Pressure Alarm Limits
122
Setting of Upper and Lower Arterial Pressure Alarm Limits
122
Setting of Upper and Lower Dialysate Pressure Alarm Limits
123
Completion of Dialysis (Recovery Process)
124
Check of UF Completion
124
Start of Blood Recovery
124
Execution of Blood Recovery
125
Removal of Coupler
125
Clearing Away
126
Completion of Blood Recovery
126
Discontinuance of Dialysis
127
Discontinuance of UF
127
16 Single Needle Dialysis
128
Setting of Dialysate Related Parameters
129
Setting of Dialysis Mode
129
Setting of Dialysate Concentration
129
Bicarbonate Dialysate
129
Acetate Dialysate
130
Setting of Dialysate Temperature
130
Connection of Concentrates
131
Connection of Concentrates to Prepare Bicarbonate Dialysate
131
Connection of Concentrate to Prepare Acetate Dialysate
131
Setting of Blood Line, Dialyzer and Syringe
132
Setting of Blood Line
132
Setting of Dialyzer
132
Setting of Syringe
132
Setting of Syringe Pump
133
Setting of Cross-Section Ratio of Syringe
133
Setting of Fast-Forward Volume
134
Setting of Syringe Operation Stop Time
134
Preparation of Machine (Preparation Process)
135
Check of Preparation Completion of Machine (Preparation End Process)
135
Priming Process
136
Setting of Saline Vial
136
Priming of Saline
136
Priming of Dialyzer with Dialysate
137
Rinsing of Blood Line and Dialyzer
137
When Priming Function Is Used
137
When Priming Function Is Not Used
138
Check of Dialysate Conductivity
139
Setting of UF Related Parameters
139
Connection of Patient
140
Setting of Single Needle Dialysis Related Parameters
141
Single Needle SW on
141
Setting of Single Needle Changeover Values
141
Start of Dialysis (Dialysis Process)
142
Start of Dialysis
142
Setting of Upper and Lower Arterial Pressure Alarm Limits
142
Setting of Upper and Lower Dialysate Pressure Alarm Limits
143
Completion of Dialysis (Recovery Process)
144
Check of UF Completion
144
Start of Blood Recovery
144
Execution of Blood Recovery
145
Removal of Coupler
145
Clearing Away
146
Completion of Blood Recovery
146
Discontinuance of Dialysis
147
Discontinuance of UF
147
17 Sequential Dialysis
148
ON Setting of Sequential Dialysis
148
OFF Setting of Sequential Dialysis
148
18 Check and Maintenance
150
Check and Maintenance by Operator
150
Check and Maintenance before and after Operation
150
Test Mode
150
Cleaning and Disinfection of Machine Outside
151
Disinfection and Rinsing of Fluid Line Inside
151
Acetic Acid Rinsing of Fluid Lines
151
Regular Check by Engineer
152
Check before Power on
153
Check of Leakage Current
154
Check of Accuracy of Pressure Sensor
155
Check of Syringe Pump
156
Check for Fixation of Pulley
156
Check of Accuracy of UF
157
Check of Accuracy of Blood Leak Sensor
158
Visual Check of Blood Leak Sensor
158
Zero Revisions of Blood Leak Sensor
159
Check of Accuracy of Blood Pump Flow Rate
160
When Electronic Balance Is Used
160
When Measuring Cylinder Is Used
160
Check of Accuracy of Bubble Sensor
161
Preferable Method
161
Simple Method
161
Check of Accuracy of Temperature Sensor
162
Check of Accuracy of Conductivity Cell
163
Replacement of Components of GVS Filter (Supply Water Line)
164
Replacement of Components of Electromagnetic Valve
165
Replacement of Component of Pump
168
Contents Parts List
168
Overall Views of Pump
168
Replace Method
170
Maintenance by Qualified Engineer
173
19 Storage
174
Actions before Storing Machine
174
Cleaning of Enclosure
174
Priming of Formalin Solution
174
Environmental Conditions Required to Store Machine
175
Check and Test before Re-Operation of Machine
175
20 Machine Moving and Cautions
176
21 Specifications
179
Specifications for Machine
179
Dimension and Weight
179
Power Source
179
Electric Safety
179
Environment
180
Performance of Machine
182
Dialysate Flow Rate
182
Deaeration
182
UFR Control
182
Temperature Control
182
Conductivity Control
183
Conductivity Control (ACETATE)
183
Disinfection Control
184
Acid Rinse Control
184
Water Rinse Control
184
Blood Pump
185
Syringe Pump
185
Safety Monitors
186
Bubble Detector
186
Dialysate Pressure Monitor
186
Venous Pressure Monitor
186
Blood Leak Detector
187
Conductivity Monitor
187
Temperature Monitor
187
Specifications for Options
188
Arterial Pressure Sensor
188
Backup Unit of Blood Pump for Power Failure
188
Energy Cell Specification
188
Machine Specification
188
Acid Rinse Port Unit
189
Heat Exchanger
189
Hot Chemical Disinfectant Rinse Control
189
Hot Rinse Assy
189
Hot Water Rinse
190
Large Single Lump Assy
190
Special Note
190
Language
190
22 Data for Use
191
Blood Tubing Set Applicable to SURDIAL 22.1.1 A065(A067) / V643
191
A064(A066) / V643
192
Layouts of Blood Tubing 22.2.1 Model A065(A067) / V643
194
Model A064(A066) / V643
195
Flow Chart and Components of SURDIAL
196
Flow Chart
196
Component of SURDIAL
197
Advertisement
Related Products
Nipro SUREFUSER+
Nipro SMA-0123-10P
Nipro SMA-3456-25P
Nipro SMA-2345-30P
Nipro SMA-2468-30P
Nipro SFS-3-15P
Nipro SFS-2-30P
Nipro SFS-4-30P
Nipro SFS-5-30P
Nipro SFS-6-30P
Nipro Categories
Blood Glucose Meter
Medical Equipment
Water Filtration Systems
Water Dispenser
Water System
More Nipro Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL