Sign In
Upload
Manuals
Brands
National Instruments Manuals
I/O Systems
SC Express PXIe-4309
National Instruments SC Express PXIe-4309 Manuals
Manuals and User Guides for National Instruments SC Express PXIe-4309. We have
3
National Instruments SC Express PXIe-4309 manuals available for free PDF download: User Manual, Getting Started Manual And Specifications, Calibration Procedure
National Instruments SC Express PXIe-4309 User Manual (32 pages)
32 Ch 8 ADC, 2 MS/s, 18 - 28 bit, Flexible Resolution PXI Analog Input Module
Brand:
National Instruments
| Category:
I/O Systems
| Size: 1 MB
Table of Contents
Table of Contents
5
Chapter 1
7
Getting Started
7
Installation
7
Module Specifications
7
Chapter 2
8
Using the Pxie-4309
8
Connecting Signals
8
Connecting Voltage Signals
8
Analog Input Circuitry
9
Figure 2-1. Analog Input Circuitry
9
Figure 2-2. Signal Source with Common-Mode Connected to an Analog Input Channel
9
Figure 2-3. Recommended Wiring for a Floating Source
10
Figure 2-4. Recommended Wiring for a Grounded Source with Common-Mode
10
Module Pinout
11
Figure 2-5. Recommended Wiring for a Grounded Source
11
Table 2-1. Pxie-4309 Front Connector Signal Pin Assignments
12
I/O Connector Signal Descriptions
13
Table 2-2. I/O Connector Signal Descriptions
13
Pxie-4309 Block Diagram
14
Figure 2-6. Pxie-4309 Block Diagram
14
Signal Acquisition Considerations
15
Adc
15
Single Channel Per ADC
15
Multiple Channels Per ADC
15
Table 2-3. AI Channel to ADC Mapping
15
Sample Modes
16
Averaging Acquisition
16
Figure 2-7. Single Channel Averaging
17
Figure 2-8. Multiple Channel Averaging
17
Table 2-4. Maximum Sample Rate
17
Single Convert Acquisition
18
Figure 2-9. Single Convert Acquisition of a Single Channel
18
Figure 2-10. Single Convert Acquisition of Two Channels on the same ADC
18
Table 2-5. Maximum Sample Rate (Hardware-Timed Single Point, On-Demand, and External Sample Clock)
18
Sample Timing Modes
19
Software-Timed Acquisitions
19
Hardware-Timed Acquisitions
19
Offset Error Cancellation Techniques
20
Auto Zero
20
Figure 2-11. Analog Input Auto Zero
20
Chopping
22
Figure 2-12. Analog Input Chopping
22
Table 2-6. Maximum Sample Rate (Auto Zero Every Sample)
22
Table 2-7. AI Channel Connection Pairing for Chopping Channels
23
Table 2-8. Maximum Sample Rate (Chopping Enabled)
23
Timing and Triggering
24
Sample Clock Timebase
24
External Clock
24
Digital Triggering
24
Pfi
24
Using PFI Terminals as Timing Input Signals
25
Exporting Timing Output Signals Using PFI Terminals
25
Figure 2-13. PFI Circuitry
25
Connecting PFI Input Signals
26
PFI Filters
26
Table 2-9. Debouncing Filters
26
I/O Protection
27
Synchronization
27
Reference Clock Synchronization
27
Accessory Auto-Detection
28
Chapter 3
29
SC Express Considerations
29
SC Express Clock and Trigger Signals
29
Pxie_Clk100
29
Pxi_Clk10
29
PXI Triggers
29
PXI_STAR Trigger
29
Pxie_Dstar<A..C
30
Table 3-1. Pxie_Dstar Line Descriptions
30
Appendix A
31
NI Services
31
Advertisement
National Instruments
PXIe-4309
Getting Started Manual And Specifications
National Instruments SC Express PXIe-4309 Getting Started Manual And Specifications (26 pages)
32 Ch (8 ADC), 2 MS/s, 18 - 28 bit, Flexible Resolution PXI Analog Input Module
Brand:
National Instruments
| Category:
I/O Systems
| Size: 2 MB
Table of Contents
Table of Contents
2
Electromagnetic Compatibility Guidelines
3
What You Need to Get Started
4
Installation
4
Install the Software
4
Create a Simulated Device
5
Unpack the Kit
5
Install the Hardware
5
Connect the Signals
7
Install the Terminal Block
13
Confirm Pxie-4309 Module Recognition
14
Run Test Panels
16
Take an NI-Daqmx Measurement
16
NI-Daqmx Channels and Tasks
16
Configure a Task Using the DAQ Assistant in MAX
16
Use Your Pxie-4309 Module in an Application
17
Programming Examples
17
Terminal Block Removal
18
Module Removal
19
More Information
20
Troubleshooting
20
Specifications
20
Calibration
20
Electrical
20
Mechanical
20
Physical Characteristics
21
Environmental
22
Operating Environment
22
Storage Environment
22
Shock and Vibration
22
Safety
23
Safety Standards
23
Electromagnetic Compatibility
23
CE Compliance
24
Online Product Certification
24
Environmental Management
24
Worldwide Support and Services
25
National Instruments SC Express PXIe-4309 Calibration Procedure (18 pages)
32 Ch (8 ADC), 2 MS/s, 18 - 28 bit, Flexible Resolution PXI Analog Input Module
Brand:
National Instruments
| Category:
I/O Systems
| Size: 1 MB
Table of Contents
Table of Contents
1
Software
1
Documentation
2
Test Equipment
3
Test Conditions
4
Initial Setup
4
Self Calibration
4
Verification
5
DC Offset Accuracy
6
DC Voltage Accuracy
9
Adjustment
13
EEPROM Update
16
Reverification
17
Specifications
17
Worldwide Support and Services
17
Advertisement
Advertisement
Related Products
National Instruments NI PXIe-4300
National Instruments PXIe-4339
National Instruments NI PXIe-4463
National Instruments NI PXIe-7861
National Instruments PXIe-7857R
National Instruments PXIe-7868R
National Instruments PXIe-7865
National Instruments PXIe-7866
National Instruments PXIe-7856
National Instruments PXIe-7822
National Instruments Categories
Control Unit
I/O Systems
Controller
Computer Hardware
Measuring Instruments
More National Instruments Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL