National Instruments NI PXI-5122 Manuals
Manuals and User Guides for National Instruments NI PXI-5122. We have
3
National Instruments NI PXI-5122 manuals available for free PDF download: Calibration Procedure, Getting Started Manual
National Instruments NI PXI-5122 Calibration Procedure (46 pages)
Brand:
National Instruments
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
1
Software Requirements
1
Documentation Requirements
2
Password
2
Calibration Interval
3
Test Equipment
3
Test Conditions
3
Calibration Procedures
4
Initial Setup
4
Self-Calibration
4
Max
4
NI-SCOPE Soft Front Panel
5
Ni-Scope
5
Verification
5
Vertical Offset and Vertical Gain Accuracy
6
Programmable Vertical Offset Accuracy
17
Timing Accuracy
22
Bandwidth and Flatness
26
Trigger Sensitivity
34
Adjustment
39
Appendix A: Calibration Options
42
Complete Calibration
43
Optional Calibration
43
Appendix B: Calibration Utilities
45
Max
45
Ni-Scope
45
Worldwide Support and Services
45
Advertisement
National Instruments NI PXI-5122 Getting Started Manual (32 pages)
High-Speed Digitizers
Brand:
National Instruments
| Category:
Measuring Instruments
| Size: 22 MB
Table of Contents
Table of Contents
2
Conventions
3
Verifying System Requirements
4
Unpacking
4
Verifying the Kit Contents
5
Other Required Items
6
Installing the Software
6
Installing the Hardware
7
PXI Modules
7
PXI Express Modules
8
PCI Devices
9
Configuring and Testing in MAX
11
Programming the Digitizer
13
Acquiring Data Interactively
13
Acquiring Data Programmatically
13
NI-SCOPE Examples
13
NI Example Finder
13
Making Your First Measurement
13
Appendix A: Front Panels for SMC-Based Devices
14
NI 5105 Front Panels
15
NI 5114 Front Panels
16
NI 5122/5124/5142/5922 Front Panels
17
NI 5152 Front Panels
19
Appendix B: Front Panels for Traditional NI-DAQ (Legacy) Devices
20
NI 5102 Front Panels
20
NI 5112 Front Panels
24
NI 5620/5621 Front Panels
25
NI 5911 Front Panel
26
Appendix C: Troubleshooting
27
Front Panel ACCESS LED on PXI Module Is off When PXI Chassis Is on
27
Device Does Not Appear in MAX
27
Device Failed the Self-Test
28
Thermal Shutdown Error
28
Performance Issues Using MXI Connections
28
Setting up SMC-Based Devices for Synchronization
29
NI 5112 Programming Practices
29
Appendix D: Where to Go for Support
30
National Instruments NI PXI-5122 Calibration Procedure (32 pages)
Brand:
National Instruments
| Category:
Test Equipment
| Size: 0 MB
Table of Contents
Table of Contents
1
Conventions
2
Introduction
3
What Is Calibration
3
Self-Calibration
3
External Calibration
3
Why Should You Calibrate
3
How Often Should You Calibrate
4
Software and Documentation Requirements
4
Software
4
Documentation
6
Self-Calibration Procedures
6
Max
6
Scope SFP
7
Ni-Scope
7
External Calibration Options
8
Complete Calibration
9
Optional Calibration
10
External Calibration Requirements
12
Test Equipment
12
Test Conditions
12
External Calibration Procedures
13
Verifying ni 5122 Specifications
13
Vertical Offset and Vertical Gain Accuracy
13
Programmable Vertical Offset Accuracy
19
Timing Accuracy
21
Bandwidth and Flatness
23
Trigger Sensitivity
26
Adjusting the ni 5122
28
Calibration Utilities
30
Max
30
Ni-Scope
30
Advertisement
Advertisement
Related Products
National Instruments PXI-5152
National Instruments PXI-5153
National Instruments NI PXI-5124
National Instruments PXI-5142
National Instruments NI PXI-5102
National Instruments NI PXI-5112
National Instruments NI PXI-562X
National Instruments NI PXI-5621
National Instruments PXI-5661
National Instruments PXI-5660