Sign In
Upload
Manuals
Brands
Mitsubishi Heavy Industries Manuals
Air Conditioner
KX6 series
Mitsubishi Heavy Industries KX6 series Manuals
Manuals and User Guides for Mitsubishi Heavy Industries KX6 series. We have
4
Mitsubishi Heavy Industries KX6 series manuals available for free PDF download: Service Manual, Technical Manual
Mitsubishi Heavy Industries KX6 series Service Manual (217 pages)
VRF INVERTER MULTI-SYSTEM AIR CONDITIONERS
Brand:
Mitsubishi Heavy Industries
| Category:
Air Conditioner
| Size: 45 MB
Table of Contents
Service Manual
1
Table of Contents
2
1 Outline of Operation Control by Microcomputer
3
Wired Remote Controller (Option Parts)
3
Dehumidifying Operation
4
Operation Control Function by the Indoor Controller
4
Operations of Functional Items During Cooling/Heating
4
Timer Operation
4
Fan Control During the Heating Thermostat off
5
Hot Keep
5
Hot Start (Prevention of Cold Draft During Heating)
5
Remote Controller Display During the Operation Stop
5
Auto Swing Control
6
Compressor Inching Prevention Control
6
Filter Sign
6
Drain Motor (DM) Control
7
Indoor Heat Exchanger Anti-Frost (Anti-Frost Control)
7
Operation Check/Drain Pump Test Run Operation Mode
7
Detection Room Temperature Compensation During Heating
8
High Ceiling Control
8
Hot Start
8
Return Air Temperature Compensation
8
Dip Switch Function
9
Fresh Air Processing Operation Input
9
Processing of Emergency Stop Signal
9
Remote Operation Input
9
Operation Control Function by the Remote Controller
10
Parts Layout on Remote Controller PCB
10
Normal Control
11
Operation Control Function by the Outdoor Controller
11
Compressor Pre-Start Control
12
Remote Controller Full Stop-Operation
12
Cooling-Heating
13
Heating-Cooling
14
4-Way Valve Switching Safeguard
15
Compressor Control
15
Compressor Protection Start
15
Fan Control During Cooling
17
Outdoor Fan Control
17
Outdoor Fan Speed and Fan Motor Rotation Speed
17
Outdoor Fan Cooling Control at Low Outdoor Air Temperature
18
Outdoor Fan Heating Control
18
Defrost Control
19
Temperature Condition of Defrosting
19
Protective Control
20
Time Condition of Defrosting
20
Optional Controls
21
Test Run
21
Demand Control
22
External Input and Demand Input
22
Operation Permission and Prohibition Modes
22
2-Step Demand Control
24
Control Contents
25
End Condition
25
Silent Mode Control
25
Start Conditions
25
External Output
26
Outdoor Fan Snow Protection Control
26
Emergency Stop Control
27
Energy Saving Mode Control
27
Forced Cooling/Heating Operation
27
Pump down Operation Control for Removal of the Unit
28
7-Segment and Operation Data Retention
29
Data Output
29
Operation Information Display
29
Precedence of Display
30
List of 7-Segment Displays
31
Compressor Stop Cause (Cord No. C68)
33
Error Retention and Monitoring Data
36
Saving of Operation Data
36
Outdoor Unit Information
37
Sensor Value
37
PCB Hardware Input
38
PCB Hardware Output
39
Related to Compressor
39
Error Counter Information
40
Setting Value Display
40
2 System Troubleshooting Procedure
42
Basics of Troubleshooting
42
Checking 15V on the Control PCB
43
Explanation of Troubleshooting
43
Inspection of Short-Circuit on the Power Transistor Module Terminals
43
Contents of Troubleshooting
44
Indoor and Outdoor Units
44
List of Inspection Displays
44
Optional Controller In-Use
44
Operates but Does Not Cool
45
Troubleshooting
45
Operates but Does Not Heat
46
Earth Leakage Breaker Activated
47
Excessive Noise/Vibration
48
Louver Motor Anomaly
51
Power Supply System Anomaly (Power Supply to Indoor Unit PCB)
52
Power Supply System Error (Power Supply to Remote Controller)
53
Wait (1)
54
Wait (2)
55
Wait (3)
56
Wait (4)
57
Wait (5)
58
Wait (6)
59
No Display
60
Remote Controller Communication Error
61
Duplicated Indoor Unit Address
62
Outdoor Unit Signal Line Error
63
Communication Error During Operation
64
Indoor Heat Exchanger Temperature Thermistor Anomaly (Thi-R)
65
Indoor Return Air Temperature Thermistor Anomaly (Thi-A)
66
Drain Trouble
67
Excessive Number of Indoor Units by Controlling One Remoto Controller
68
Address Setting Error by Mixed Setting Method
69
Indoor Fan Motor Anomaly (FDT and FDTC Series)
70
Indoor Fan Motor Anomaly (FDK and FDFW Series)
71
Address Setting Error of Master and Slave Indoor Units
72
Indoor Unit Operation Check, Drain Motor Check Mode Anomaly
73
Indoor Fan Motor Rotation Speed Anomaly
74
Remote Controller Temperature Thermistor Anomaly (Thc)
75
Unmatch Connection of Indoor and Outdoor Unit
76
Duplicated Outdoor Unit Address No.
77
Open L3 Phase on Power Supply at Primary Side
78
Discharge Pipe Temperature Error (Tho-D1)
79
Liqiud Flooding Anomaly
80
Outdoor Air Temperature Thermistor Anomaly (Tho-A)
82
Discharge Pipe Temperature Thermistor Anomaly (Tho-D1)
83
High Pressure Anomaly (63H1-1Activated)
84
Power Transistor Overheat
85
Current Cut (CM1)
86
Excessive Number of Indoor Units Connected
87
Excessive Total Capacity of Connection
87
Communication Error between Inverter PCB and Outdoor Control PCB
88
Mixed Address Setting Methods Coexistent in same Network
89
Outdoor DC Fan Motor Anomaly
90
Low Pressure Anomaly
91
Suction Pipe Temperature Thermistor Anomaly (Tho-S)
92
Under-Dome Temperature Thermistor Anomaly (Tho-C1)
92
High Pressure Sensor Anomaly (PSH)
93
Low Pressure Sensor Anomaly (PSL)
93
Power Transistor Temperature Thermistor Anomaly (Tho-P1)
94
Anomalous Compressor by Loss of Synchronism
95
Compressor Startup Failure (CM1)
96
Rotor Position Detection Failure (CM1)
97
Emergency Stop
98
Outdoor Unit Control PCB Replacement Procedure
99
Precautions for Safety
99
Appearance of the Controller
100
Voltage Measurement Points
100
Inverter PCB Replacement Procedure
101
Installation Method to Power Transistor
102
Function of Connector
103
Function of Dip Switch for Control (SW3, 4, 5)
103
Function of Jumper Wire (J13, 15)
103
3 Electrical Wiring
104
DIP Switch Setting List
104
Outdoor Unit
104
Indoor Unit
104
Electrical Wiring
105
Models FDC224KXE6M, 280KXE6M, FDCS224KXE6M, 280KXE6M
105
Models FDC335KXE6M, FDCS335KXE6M
106
Ceiling Cassette-4 Way Type (FDT)
107
Eiling Cassette-4 Way Compact Type (FDTC)
108
Ceiling Cassette-2 Way Type (FDTW)
109
Models FDTW28KXE6D, 45KXE6D, 56KXE6D
109
Ceiling Cassette-1 Way Compact Type (FDTQ)
110
Direct Blow Type
110
Duct Type
111
Ceiling Cassette-1 Way Type (FDTS)
112
Model FDTS45KXE6D
112
Model FDTS71KXE6D
113
Duct Connected-High Static Pressure Type (FDU)
114
Models FDU224KXE6D, 280KXE6D
114
Duct Connected-Low/Middle Static Pressure Type (FDUM)
115
Models FDUM112KXE6D, 140KXE6D
116
Duct Connected (Thin)-Low Static Pressure Type (FDUT)
117
Duct Connected-Compact and Flexible Type (FDUH)
118
Wall Mounted Type (FDK)
119
Models FDK22KXE6D, 28KXE6D, 36KXE6D, 45KXE6D, 56KXE6D
119
Model FDK71KXE6D
120
Ceiling Suspended Type (FDE)
121
Models FDE36KXE6D, 45KXE6D, 56KXE6D
121
Models FDE71KXE6D, 112KXE6D, 140KXE6D
122
Floor Standing-2 Way Type (FDFW)
123
Outdoor Air Processing Unit (FDU-F)
124
Indoor Unit
124
Piping System
125
Models FDC224KXE6, 280KXE6M-FDCS224KXE6M, 280KXE6M
125
Models FDC335KXE6M-FDCS335KXE6
126
4 Piping System
127
5 Application Data
127
Installation of Indoor Unit
127
Before Installation
128
Ceiling Cassette-4 Way Type (FDT)
128
Preparation before Installation
128
Selection of Installation Location for the Indoor Unit
128
Drain Pipe
129
Refrigerant Pipe
129
Check List after Installation
130
How to Check the Dirt of Drain Pan (Maintenance)
130
Panel Installation
130
Wiring-Out Position and Wiring Connection
130
Attaching the Panel
131
Checking the Indoor Unit Installation Position
131
Orientation of the Panel Installation
131
Panel Installation Manual
131
Attaching a Corner Pane
132
Attaching the Air Return Grille
132
How to Set the Airflow Direction
132
Ceiling Cassette-4 Way Compact Type (FDTC)
133
Refrigerant Pip
134
Attaching a Corner Panel
136
Orientation of the Panel and Return Air Grille Installation
136
Removing a Corner Panel
136
How to Set the Airflow Direction
137
Ceiling Cassette-2 Way Type (FDTW)
138
Ceiling Cassette-1 Way Compact Type (FDTQ)
141
The Indoor Unit Change Procedure for Duct Type
142
Accessories
144
Confirm the Mounting Level of Main Unit
144
Mount the Panel
145
Changing the Fan Tap
146
Invalidating the Louver Switch
146
Main Body Change Procedure for Duct Type
146
Parts Models: QR-PNA-14W-ER, QR-PNB-14W-ER
146
Duct Work
147
Ceiling Cassette-1 Way Type (FDTS)
149
Kx-Sm
150
Duct Connected High Static Pressure Type (FDU)
152
Duct Connected-Low/Middle Static Pressure Type (FDUM)
155
Duct Connected (Thin)-Low Static Pressure Type (FDUT)
158
Duct Connected-Compact and Flexible Type (FDUH)
161
Wall Mounted Type (FDK)
164
Shaping of Pipes and Drain Hoses
165
Ceiling Suspended Type (FDE)
167
Remote Controller
167
How to Set the Airflow Direction?
169
Floor Standing-2 Way Type (FDFW)
170
Electric Wiring Work Instruction
176
Initial Settings
179
Installation of Outdoor Unit
186
Selecting the Installation Location
187
Refrigerant Piping
188
Method for Connecting the Accessory Pipe
202
Check Operation Procedure
203
Instructions for Installing the Branch Pipe Set
211
Advertisement
Mitsubishi Heavy Industries KX6 series Service Manual (267 pages)
INVERTER DRIVEN MULTI-INDOOR UNIT CLIMATE CONTROL SYSTEM
Brand:
Mitsubishi Heavy Industries
| Category:
Air Conditioner
| Size: 15 MB
Table of Contents
Characteristics of Fan
27
Standard (Factory Settings)
33
Application Data
37
Installation of Outdoor Unit
37
Installation of Indoor Unit
53
Work Procedure
56
Drain Test
58
Drain Pump Operation
58
Drainage Test
63
Installation
73
Drain Pipe
74
Mounting the Panel
76
Connector of
76
Installation Space
85
Piping Work
88
Floor Standing Installation
116
Detach the Front Panel
118
Remote Controller Installation
118
Remote Controller Wiring
118
Wiring Route
119
Installation of Wired Remote Controller
125
Installation Procedure
125
Outline of Operation Control by Microcomputer
138
Wired Remote Controller (Optional Parts)
138
Operation Control Function by the Indoor Controller
139
Operations of Functional Items During Cooling/Heating
139
Dehumidifying Operation
139
Remote Controller Display During the Operation Stop
140
Operation Check/Drain Pump Test Run Operation Mode
142
Hot Start
143
Operation Control Function by the Remote Controller
145
Operation Control Function by the Outdoor Controller
146
Compressor Capacity Control
155
External Output
160
Tho-P1
171
System Troubleshooting Procedure
177
Basics of Troubleshooting
177
Explanation of Troubleshooting
178
Contents of Troubleshooting
179
Applicable Model
180
Condition of Error Displayed
180
Troubleshooting
180
Yes
180
Operates but Does Not Cool
180
Operates but Does Not Heat
181
Earth Leakage Breaker Activated
182
Excessive Noise/Vibration
183
All Models
185
Power Supply System Error (Power Supply to Remote Controller)
188
Error Detection Method
189
Remote Controller Communication Error
196
Communication Error During Operation
199
Is Detected for 20 Seconds
200
Temperature Thermistor (Tho-P1)
200
Indoor Heat Exchanger
200
Drain Trouble
202
Continuously Within 10 Minutes
215
Automatically after 3-Minutes
225
Delay, if this Anomaly Occurs 3
225
Times Within 40 Minutes
225
Table of Contents
227
Applicable Model
228
Error Detection Method
228
Condition of Error Displayed
228
Presumable Cause
229
Troubleshooting
229
Is the
230
Yes
230
Replace Remote Control
231
Emergency Stop
231
Precautions for Safety
232
Wireless Kit
237
Optional Parts
237
Preparation before Installation
238
Installation of the Receiver
240
Backup Button
244
How to Insert Batteries
248
Wireless Remote Controller
260
Installation of Remote Controller
262
Wiring Specifications
263
Mitsubishi Heavy Industries KX6 series Service Manual (209 pages)
INVERTER DRIVEN MULTI-INDOOR UNIT CLIMATE CONTROL SYSTEM
Brand:
Mitsubishi Heavy Industries
| Category:
Air Conditioner
| Size: 40 MB
Advertisement
Mitsubishi Heavy Industries KX6 series Technical Manual (59 pages)
VRF INVERTER MULTI-SYSTEM AIR CONDITIONERS
Brand:
Mitsubishi Heavy Industries
| Category:
Air Conditioner
| Size: 14 MB
Table of Contents
Table of Contents
2
1 Specifications
5
2 Exterior Dimensions
5
Indoor Units
5
Wired Remote Controller (Optional Parts)
8
3 Electrical Wirings
12
4 Noise Levels
12
5 Characteristics of Fan
13
6 Capacity Tables
16
7 Application Data
26
Installation of Indoor Unit
27
Installation of Wired Remote Controller
35
8 Outline of Operation Control by Microcomputer
41
Wired Remote Controller (Optional Parts)
41
Operation Control Function by the Indoor Controller
42
9 System Troubleshooting Procedure
43
Troubleshooting
43
Indoor Unit PCB Replacement Procedure
45
DIP Switch Setting List
48
Function of Connection
48
10 Optional Parts
49
Wireles Kit (RCN-KIT3-E)
49
Simple Wired Remote Controller (RCH-E3)
51
Filter Kit
57
Advertisement
Related Products
Mitsubishi Heavy Industries KXR Series
Mitsubishi Heavy Industries KX Series
Mitsubishi Heavy Industries FDC - KXZPE1 Series
Mitsubishi Heavy Industries KXZ Series
Mitsubishi Heavy Industries KXZP Series
Mitsubishi Heavy Industries KXZR Series
Mitsubishi Heavy Industries KXZW Series
mhi 1000KXZE1
Mitsubishi Heavy Industries 1000KXZRE1
Mitsubishi Heavy Industries 100VNXPVF
Mitsubishi Heavy Industries Categories
Air Conditioner
Remote Control
Heat Pump
Engine
Control Systems
More Mitsubishi Heavy Industries Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL