Sign In
Upload
Manuals
Brands
Maritime Geothermal Manuals
Heat Pump
ACE-65
Maritime Geothermal ACE-65 Manuals
Manuals and User Guides for Maritime Geothermal ACE-65. We have
2
Maritime Geothermal ACE-65 manuals available for free PDF download: Installation And Service Manual
Maritime Geothermal ACE-65 Installation And Service Manual (118 pages)
Triple Function Central Air Source Heat Pump
Brand:
Maritime Geothermal
| Category:
Heat Pump
| Size: 25 MB
Table of Contents
Average Max. Snow Depth Map - Canada
1
Table of Contents
4
Tables & Documents
5
ATF System Description
6
General Overview
6
Air Heating Mode
6
Auxiliary Air Heat
6
Defrost Operation
6
Hydronic (Water) Heating Mode
6
Auxiliary Hydronic Heat
6
Air Cooling Mode
7
Factory Options
7
Mode & Priority Selection
7
ATF Sizing
8
Air Source Heat Pumps
8
Heat Pump Sizing
8
Plenum Heater Sizing
8
Table 1 - Heat Pump Size Vs. Heated Area
8
Table 2 - Plenum Heater Sizing
8
Installation Basics
9
Sample Bill of Materials
9
Unpacking the Unit
9
Indoor Unit Placement
9
Placement of Tanks
9
Indoor Unit Air Outlet Orientation & Air Return Orientation
10
001915INF - Internal Plenum Heater Installation
11
Outdoor Unit Placement
12
Outdoor Fan Speed Reduction
12
Outdoor Unit Mounting Height
12
Wiring
14
Indoor Unit Power Supply Connections
14
Outdoor Unit: Power Connections
14
Plenum Heater: Power Connections
14
Plenum Heater: Signal Connections
14
Indoor Loop Circulator Pump Wiring
14
Table 3 - Power Supply Connections
14
Table 4 - Outdoor Unit Power Supply Connections
14
Table 5 - Plenum Heater Signal Connections
14
Table 6 - Indoor Loop Circulator Connections
14
Control Transformer
15
Bacnet Connections
15
Disable Switch (Field Installed)
15
Setpoint Control (Hydronic Control) Connections
15
Setpoint Control: Aux. Connections
15
Table 7 - Control Transformer
15
Table 8 - Bacnet Connections
15
Table 9 - Setpoint Control: Aux. Connections
15
Outdoor Unit: Signal Connections
16
Air Thermostat Connections
16
Aquastat Connections (Optional)
16
Table 10 - Outdoor Unit Signal Connections
16
Table 11 - Air Thermostat Connections
16
Table 12 - Aquastat Connections (Optional)
16
002071CDG - Typical GEN2 Thermostat Connections
17
002304CDG - Typical ATF Wiring
18
002375QSS - Eco Ultra Tanks: Getting Started
19
002067CDG - Typ. Heating Only Zone Wiring (Setpoint)
20
002069CDG - Typ. Htg. Only Zone Wiring (Hardwired)
21
Piping
22
Indoor Loop Water Lines
22
Condensate Drain
22
Domestic Hot Water (Desuperheater) Connections
22
Table 13 - Buffer Tank Size
22
002305PDG - Typical Piping Connections - ATF
23
002366PDG - Recommended Buffer Tank Piping
24
000538PDG - Buffer Tank Piping - Multiple Units
25
002367PDG - Auxiliary Boiler Piping
26
000530PDG - Typical Zone Types
27
001055PDG - Connection to On-Demand DHW Tank
28
000970PDG - Desup. Conn. to DHW Pre-Heat Tank
29
002384PDG - DHW Pre-Heat Tank - Multiple Units
30
Outdoor Unit Line Set
31
Line Set Interconnect Tubing
31
Indoor Unit Connections
31
Outdoor Unit Connections
31
Oil Traps
31
Filter-Dryer
31
Table 14 - Line Set Sizing
31
Table 15A - 3-Way Service Valve Tooling
31
Table 15B - 3-Way Service Valve Torques
31
Pipe Insulation
32
Silver Soldering Line Sets
32
Pressure Testing
32
Vacuuming the System
32
Charging the System
32
Table 16 - Extra Charge for Model Sizes 25-45
32
Table 17 - Extra Charge for Model Sizes 55-75
32
002250CDG - Typical Line Set Connections
33
Ductwork
34
Indoor Unit Blower Motor
34
Duct Systems - General
34
Duct Systems - Grill Layout
34
Thermostat Location
34
Plenum Heater
34
Table 18 - Heat Pump Size Vs. Hot Air Grills
34
002249PDG - Typical Duct & Condensate Connections
35
Duct Sizing Guide
36
Table 19 - Duct Sizing Guide
36
Operation
37
Bacnet Control
37
Air Thermostat Operation
37
Hydronic Temperature Control
37
Hydronic Heating: Setpoint Control
37
Setpoint Control Method 1 - Indoor Loop (ICR)
37
Setpoint Control Method 2 - External HTS/CTS
37
Top up S1 Function
38
Summer Setback
38
Table 20 - Typical Temperature Setpoints
38
Table 21 - Maximum Output Temperature
38
Outdoor Reset
39
Hydronic Heating: Signals Control
39
PC Application (PC App)
40
LCD Interface & Menus
52
Bacnet Interface
54
Table 22 - Bacnet Objects - Control Signals (Read/Write)
54
Table 23 - Bacnet Objects - Operation Mode Description (Read Only)
54
Table 24 - Bacnet Objects - Data (Read Only)
55
Table 25 - Bacnet Objects - Alarm Descriptions (Read Only)
56
Table 26 - Bacnet Objects - Fault Descriptions (Read Only)
57
Startup Procedure
58
Startup Record
60
General Maintenance
61
Troubleshooting Guide
62
Repair Procedures
75
Pumpdown Procedure
75
General Repair Procedure
75
Vacuuming & Charging Procedure
75
Compressor Replacement Procedure
76
Outdoor Fan Replacement Procedure
76
Control Board Replacement Procedure
77
LCD Interface (Display) Board Replacement Procedure
78
Model Specific Information
79
Shipping Information
79
Refrigerant Charge
79
Indoor Loop Flow Rates
79
Operating Temperature Limits
79
Sound Levels (Dba)
79
Table 27 - Shipping Information - Indoor Unit
79
Table 28 - Shipping Information - Outdoor Unit
79
Table 29 - Refrigerant Charge
79
Table 30 - Indoor Loop Flow Rates
79
Pressure Drop Data
80
Standard Capacity Ratings
80
Table 34: Hydronic Loop Pressure Drop Data
80
Table 35 - Standard Capacity Ratings - Air Heating (60 Hz)
80
Table 36 - Standard Capacity Ratings - Air Cooling (60 Hz)
80
Table 37 - Standard Capacity Ratings - Hydronic Heating (60 Hz)
80
Performance Tables: ATF-45
81
Performance Tables: ATF-55
83
Performance Tables: ATF-65
85
Performance Tables: ATF-75
87
Electrical Specifications
89
Plenum Heater Electrical Specifications
89
Table 38 - ATF-Series Electrical Specifications
89
Table 39 - Plenum Heater Electrical Specifications
89
Indoor Airflow Data
90
Table 40 - Airflow Range for Stage 2 (Full Load)
90
Table 41 - Airflow Range for Stage 1 (Part Load)
90
Table 42 - Airflow Range for Stage 3 (Auxiliary)
90
Table 43 - Airflow Range for Fan Recirculation
90
Table 44 - Airflow Range for Emergency
90
Table 45 - Indoor Airflow Reduction for Outdoor Temperature
90
Wiring Diagram (208/230-1-60)
91
Electrical Box Layout (208/230-1-60)
92
Wiring Diagram (208-3-60)
93
Electrical Box Layout (208-3-60)
94
Wiring Diagram (460-3-60)
95
Electrical Box Layout (460-3-60)
96
ACE (Outdoor Unit) Wiring Diagrams
97
Refrigeration Circuit - Air Heating Mode
98
Refrigeration Circuit - Air Cooling / Defrost Mode
99
Refrigeration Circuit - Hydronic Heating Mode
100
Dimensions
101
Appendix A: Control Board Description
101
Updating Firmware Via PC App
107
Updating Firmware Via Jumper Pins
109
Warranty
110
Table A1 - Control Board Connector Descriptions (Top)
110
Table A2 - Control Board Connector Descriptions (Left Side)
110
Table A3 - Control Board Connector Descriptions (Bottom)
111
Table A4 - Control Board Connector Descriptions (Right Side)
112
Appendix B: USB Driver Installation
113
Appendix C: PC App Installation
114
Appendix D: Updating Firmware
115
Advertisement
Maritime Geothermal ACE-65 Installation And Service Manual (101 pages)
Reversing Air to Water Heat Pump, Two-Stage R410a, Sizes 25-75
Brand:
Maritime Geothermal
| Category:
Heat Pump
| Size: 22 MB
Table of Contents
Table of Contents
4
Tables & Documents
5
ATW System Description
6
General Overview
6
Heating Mode
6
Defrost Operation
6
Cooling Mode
6
ATW Sizing
7
Air Source Heat Pumps
7
Heat Pump Sizing
7
Auxiliary Heat Sizing
7
Table 1 - Heat Pump Size Vs. Heated Area
7
Table 2 - Auxiliary Heat Sizing
7
Installation Basics
8
Sample Bill of Materials
8
Unpacking the Unit
8
Indoor Unit Placement
8
Outdoor Unit Placement
9
Outdoor Fan Speed Reduction
9
Outdoor Unit Mounting Height
9
Average Max. Snow Depth Map - Canada
10
Wiring
11
Indoor Unit Power Supply Connections
11
Outdoor Unit: Power Connections
11
Indoor Loop Circulator Pump Wiring
11
Control Transformer
11
Bacnet Connections
11
Table 3 - Power Supply Connections
11
Table 4 - Outdoor Unit Power Supply Connections
11
Table 5 - Indoor Loop Circulator Connections
11
Table 6 - Control Transformer
11
Outdoor Unit: Signal Connections
12
Setpoint Control Connections
12
Setpoint Control: Aux. Connections
12
Aquastat Connections (Optional)
12
Disable Switch (Field Installed)
12
Table 8 - Outdoor Unit Signal Connections
12
Table 9 - Setpoint Control Connections
12
Table 10 - Setpoint Control: Aux. Connections
12
Table 11 - Aquastat (Signals Control) Connections
12
002019CDG - Typ. ATW Series Wiring
13
002375QSS - Eco Ultra Tanks: Getting Started
14
002067CDG - Typ. Heating Only Zone Wiring (Setpoint)
15
002068CDG - Typ. Htg/Cooling Zone Wiring (Setpoint)
16
002069CDG - Typ. Heating Only Zone Wiring (Signals)
17
002070CDG - Typ. Htg/Cooling Zone Wiring (Signals)
18
Piping
19
Number of Tanks
19
Indoor Loop Water Lines
19
Domestic Hot Water (Desuperheater) Connections
19
Table 12 - Buffer Tank Size
19
002239PDG - Typical Piping Connections - ATW Series
20
002366PDG - Recommended Buffer Tank Piping
21
002252PDG - Two Tank Piping with a Rev. Heat Pump
22
002367PDG - Auxiliary Boiler Piping
23
000530PDG - Typical Zone Types
24
001055PDG - Connection to On-Demand DHW Tank
25
000970PDG - Desup. Conn. to DHW Pre-Heat Tank
26
Outdoor Unit Line Set
27
Line Set Interconnect Tubing
27
Oil Traps
27
Pipe Insulation
27
Silver Soldering Line Sets
27
Pressure Testing
27
Vacuuming the System
27
Table 13 - Interconnect Line Set Sizing
27
Charging the System
28
Table 14 - Extra Charge Required
28
Table 15 - Extra Charge (Sizes 25-45)
28
Table 16 - Extra Charge (Sizes 55-75)
28
001983CDG - Typical ATW Line Set Connections
29
Operation
30
Bacnet Control
30
Signals / Hardwired Control
30
Setpoint Control
30
Setpoint Control Method 1 - Indoor Loop (ICR) One Tank
30
Typical Temperature Settings
31
Top up S1 Function
31
Summer Setback
31
Hydronic Auxiliary in Defrost
31
Table 17 - Typical Temperature Setpoints
31
Table 18 - Maximum Output Temperature
31
Outdoor Reset
32
Setpoint Control Method 2 - Indoor Loop (ICR), 2 Tanks
32
Setpoint Control Method 3 - External HTS/CTS, One Tank
33
Setpoint Control Method 4 - External HTS/CTS, 2 Tanks
34
PC Application (PC App)
35
PC Application Menus
35
LCD Interface & Menus
47
Bacnet Interface
49
Table 19 - Bacnet Objects - Control Signals (Read/Write)
49
Table 20 - Bacnet Objects - Operation Mode Description (Read Only)
49
Table 21 - Bacnet Objects - Data (Read Only)
50
Table 22 - Bacnet Objects - Alarm Descriptions (Read Only)
51
Table 23 - Bacnet Objects - Fault Descriptions (Read Only)
52
Startup Procedure
53
Pre-Start Inspection
53
Unit Startup
54
Startup Record
55
General Maintenance
56
Troubleshooting Guide
57
Troubleshooting Tools
65
Repair Procedures
66
Model Specific Information
67
Shipping Information (Indoor Unit)
67
Shipping Information (Outdoor Unit)
67
Refrigerant Charge
67
Indoor Loop Flow Rates
67
Operating Temperature Limits
67
Outdoor Unit Sound Levels (Dba)
67
Indoor Unit Sound Levels (Dba)
67
Table 24 - Shipping Information (Indoor Unit)
67
Table 25 - Shipping Information (Outdoor Unit)
67
Pressure Drop Data
68
Table 31: Loop Pressure Drop Data
68
Standard Capacity Ratings
70
Table 32 - Standard Capacity Ratings - Heating
70
Table 33 - Standard Capacity Ratings - Cooling
70
Performance Tables: ATW-25
71
Performance Tables: ATW-45
72
Performance Tables: ATW-55
73
Performance Tables: ATW-65
74
Performance Tables: ATW-75
75
Electrical Specifications
76
Table 34 - ATW-Series Electrical Data
76
Wiring Diagram (208/230-1-60)
77
Electrical Box Layout (208/230-1-60)
78
Wiring Diagram (208-3-60)
79
Electrical Box Layout (208-3-60)
80
Wiring Diagram (460-3-60)
81
Electrical Box Layout (460-3-60)
82
ACE-45/55 Wiring Diagram
83
ACE-65/75 Wiring Diagram
83
ATW-Series Refrigeration Circuit - Heating Mode
84
ATW-Series Refrigeration Circuit - Cooling/Defrost Mode
85
Dimensions: ATW-25/45
86
Dimensions: ATW-55
88
Dimensions: ATW-65/75
90
Appendix A: Control Board Description
92
Table A1 - Control Board Connector Descriptions (Top)
93
Table A2 - Control Board Connector Descriptions (Left Side)
93
Table A3 - Control Board Connector Descriptions (Bottom)
94
Table A4 - Control Board Connector Descriptions (Right Side)
95
Appendix B: USB Driver Installation
96
Appendix C: PC App Installation
97
Appendix D: Updating Firmware
98
Updating Firmware Via PC App
98
Updating Firmware Via Jumper Pins
100
Warranty
101
Advertisement
Related Products
Maritime Geothermal ACE-45
Maritime Geothermal ACE-55
Maritime Geothermal ACE-75
Maritime Geothermal ACE Series
Maritime Geothermal Nordic AC2-45
Maritime Geothermal Nordic AC2-55
Maritime Geothermal Nordic AC2-65
Maritime Geothermal Nordic AC2-75
Maritime Geothermal Nordic AC2-80
Maritime Geothermal ATF-45
Maritime Geothermal Categories
Heat Pump
More Maritime Geothermal Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL