Transducer
979 Series
User Manuals: Kurt J. Lesker 979 Series Transducer
Manuals and User Guides for Kurt J. Lesker 979 Series Transducer. We have
1
Kurt J. Lesker 979 Series Transducer manual available for free PDF download: Operation And Maintenance Manual
Kurt J. Lesker 979 Series Operation And Maintenance Manual (54 pages)
ATV (Atmosphere to Vacuum) Transducer
Brand:
Kurt J. Lesker
| Category:
Transducer
| Size: 0 MB
Table of Contents
Table of Contents
5
Package Contents
9
Symbols Used in this Manual
10
Safety Precautions
11
General Specifications
13
Feature and Control Locations
14
About the 979 ATV Transducer
15
Typical Applications for the 979 ATV Transducer
16
Installing the 979 ATV Transducer
17
ATV Transducer Installation
17
Location
17
Orientation
17
Contamination
18
Vacuum Connection
18
Electrical Connection
19
Input/Output Wiring
19
979 ATV Transducer Electrical Connections Table
20
Relay Inductive Loads and Arc Suppression
20
Operation
22
979 ATV Transducer Factory Defaults Table
22
RS-485 Protocol
23
Standard Addresses
23
Universal Addresses
23
Query and Command Syntax
23
Response Syntax (ACK/NAK)
24
RS-485 Command Set
25
Set up Commands
25
Active Filament - AF
25
Address - AD
25
Baud Rate - BR
26
Emission Current - EC
26
Factory Default - FD
26
RS Delay - RSD
27
Test RS485 - TST
27
Unit - U
27
User Tag - UT
27
Status Commands
28
Device Type - DT
28
Filament Status - FS
28
Firmware Version Micropirani - FV
28
Firmware Version Hot Cathode - FVHC
28
Hardware Version Micropirani - HV
28
Hardware Version Hot Cathode - HVHC
28
Model - MD
29
Serial Number - SN
29
Time on - TIM1, TIM2
29
Transducer Status - T
29
Transducer Temperature - TEM1, TEM2
30
Pressure Measurement and Degas Commands
30
Filament Power - FP
30
Degas Power - DG
30
Pressure Reading - PR1, PR2, PR3
31
Set Point Commands
31
Set Point Value - SP1, SP2, SP3
31
Hysteresis Value - SH1, SH2, SH3
31
Set Point Direction - SD1, SD2, SD3
31
Enable Set Point - EN1, EN2, EN3
32
Enable Control Set Point - ENC
32
Set Point Status - SS1, SS2, SS3
32
Protect Set Point - PRO
33
Calibration Commands
33
Atmospheric Calibration - ATM
33
Vacuum Calibration - VAC
33
Gas Type Calibration - GT
34
Gas Correction - GC
34
Degassing the Sensor
35
Sensitivities Relative to Nitrogen
36
Gas Correction Factor Table
36
Analog Output
37
Pressure to Voltage Table
38
Leak Detection
41
Bakeout/Sensor Replacement
42
Bakeout
42
Sensor Replacement
43
Maintenance and Troubleshooting
44
Maintenance and Troubleshooting Table
44
Cleaning the 979 ATV Transducer Case and Sensor Tube
45
Sensor Test Resistance Values Table
46
Accessories and Part Replacement
47
Notes
48
Appendix: How the 979 ATV Transducer Works
49
Hot Cathode Ionization Sensor
49
Pirani Sensor
50
Micropirani Sensor
51
Advertisement
Advertisement
Related Products
Kurt J. Lesker 902 Piezo Series
Kurt J. Lesker 100014434
Kurt J. Lesker Categories
Measuring Instruments
Transducer
Power Supply
Accessories
More Kurt J. Lesker Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL