Table of Contents
3
1 Introduction
11
Manual Breakdown
12
Further Modules
13
2 Safety and Reliability
15
Target Group
15
Reliability
15
Notes
16
Danger
16
Dangers Caused by High Contact Voltage
16
Important Information / Cross Reference
16
Safety
17
To be Observed During Project Planning and Installation
17
To be Observed During Maintenance and Servicing
18
Electromagnetic Compatibility
19
Definition
19
Resistance to Interference
19
Interference Emission
20
General Notes on Installation
20
Protection against External Electrical Influences
21
Cable Routing and Wiring
21
Location of Installation
22
Particular Sources of Interference
22
3 Modules and Slots
23
Design
24
Screw-Type Locking Connectors
25
Coding
25
Slots
26
Function Slots
26
Service Modules
27
Transfer Address Ranges
27
Interrupt Modules
27
Power Supply of Inputs and Outputs
28
Differences between KUAX 680C/KDT 680CT and KUAX 680I
29
4 Digital Inputs and Outputs
31
Plugging Digital Input and Output Modules
32
Addressing (Input/Output Groups and Channels)
32
Reserved Slots
33
Digital Input Modules
34
Input Module, 24 V DC, 8 Inputs
35
Technical Specifications
36
Input Module, 24 V DC, 8 Inputs, with Real-Time Clock
37
Real-Time Clock
37
Parameters of KUBES Module "CLOCK
38
Programming Suggestion for the Real-Time Clock
40
4.2.2.4. Technical Specifications
41
Technical Specifications
41
Input Module, 24 V DC, 16 Inputs
42
Technical Specifications
43
Storage Temperature
43
Input Module, 24 V DC, 8 Inputs, 1 Ms
44
Technical Specifications
45
Input Module, 24 V DC, 16 Inputs, 1 Ms
46
Technical Specifications
47
Input Module, 24 V DC, 16 Inputs, Interrupt Capability
48
Signal Delay
48
Interrupt Inputs
50
4.2.6.3. Technical Specifications
53
Technical Specifications
53
Digital Output Module, 24 V DC, 0.5 A, 8 Outputs
54
Technical Specifications
56
Digital Input/Output Module, 24 V DC, 8/8
57
Inputs
57
Technical Specifications
58
(Incl. Residual Ripple)
58
Colour
58
Indicators
58
Input Voltage
58
LED on 0: LED off Addressing
58
Potential Separation
58
Surge Immunity
58
Tapping Point
58
Type (Acc. to IEC 1131)
58
Pneumatic Output Module, 4 Outputs 3/2 Way
59
Technical Specifications
60
5 Analogue Inputs and Outputs
61
Plugging Analogue Input and Output Modules
62
Addressing (Anal. Input/Output Groups and Channels)
62
Reserved Slots
63
Analogue Input Modules
65
Analogue Input Module, 0
65
Slots
65
Connectors
66
Representation of the Analogue Value
66
Technical Specifications
67
Analogue Input Module, 0(4)
68
Slots
68
Connections
69
Representation of the Analogue Value
69
Transfer Address Ranges
70
Technical Specifications
71
Admissible Ambient Conditions
71
Ambient Temp. During Operation
71
Inputs
71
Relative Humidity
71
Storage Temperature
71
Analogue Input Module, PT100, 0
72
Slots
72
Connectors
73
Transfer Address Ranges
74
Evaluation in the User Program
75
Technical Specifications
76
Part Number
76
Potential Separation
76
Weight
76
Analogue Input Module, Thermocouple Nicrni (Type K)
77
Slots
77
Connections
78
Transfer Address Ranges
79
Evaluation in the User Program
80
Technical Specifications
81
Analogue Input Module, Potentiometer, 10Bit, 4 Channels
82
Slots
82
Connectors
83
Representation of the Analogue Value
84
Technical Specifications
85
Analogue Output Modules
87
Analogue Output Module, 0
87
Slots
87
Connectors
88
Technical Specifications
89
Analogue Output Module, 0(4)
91
Slots
91
Connectors
92
Repesentation of the Analogue Value
92
Transfer Address Ranges
93
Technical Specifications
94
Analogue Input/Output Modules
95
Analogue I/O Module, 2 I 0
95
Slots
96
Connectors
97
Representation of the Analogue Value
98
Technical Specifications
99
Analogue I/O Module, 2 I 0
100
Slots
100
Connectors
101
Representation of the Analogue Value
102
Transfer Address Ranges of the Analogue Inputs
103
Technical Specifications
104
Analogue I/O Module, 2 I 0
105
Slots
106
Connectors
107
Representation of the Analogue Value
108
Transfer Address Ranges of the Analogue Inputs
109
Technical Specifications
110
Anal. I/O Module, 2 I 0
111
Slots
111
Connectors
112
Representation of the Analogue Value
113
Transfer Address Ranges
114
Technical Specifications
115
6 Counter Modules
117
Counter Module, 1 or 2 Multi-Function Counters, 24Bit
118
Functions
118
Slots
118
Counter Modules with 24V Inputs
119
Connectors
119
Technical Specifications
121
Counter Module with RS422 Interface
122
Connectors
122
Technical Specifications
123
Programming
124
Transfer Address Ranges and Interrupt Modules
124
Control Flags
126
Setting the Counter to the Preset Value / to 0
126
Setting the Reference Value
126
Counter Control
127
Reference Value
127
Interrupt
128
Counter Module, 2 Event Counters, 16Bit
129
Slots
129
Connectors
130
6.2.3. Technical Specifications
131
Technical Specifications
131
Programming
132
Transfer Address Ranges
132
Slot
132
Clearing the Count
134
Evaluating the Count
134
Selecting the Counting Direction
134
Selecting the Counting Mode
134
Setting the Counter to the Preset Value / to 0
134
Switching the Counter on / off
134
Slots
135
Function
135
SSI Module, 24 Bit, for 2 Absolute Value Devices
135
Connectors
136
6.3.3. Technical Specifications
137
Technical Specifications
137
Programming
138
Transfer Address Ranges
138
User Program
140
Clock Pulse Frequency
140
7 Communication Modules
141
RS 232) Module
141
Slots
141
Connector
142
Technical Specifications
143
Function
143
Part Number
143
Storage Temperature
143
Weight
143
TTY Module (20 Ma)
144
Slots
144
Connector
145
Technical Specifications
146
RS 485 Module
147
Slots
147
Connector
148
Technical Specifications
149
Part Number
149
Potential Separation
149
Weight
149
Programming the V.24, TTY and RS 485 Modules
150
Communication Programs SE 680I, KUSI680, RS485
150
KUBES Modules V24XE, V24XS, V24XSTRG
151
Parameters of the KUBES Modules
152
Example Program
155
PROFIBUS Modules
161
8 Stepper Motor Modules Without Processor
163
Plugging Stepper Motor Modules
164
Service Modules
165
Transfer Address Ranges
165
Assignment of Transfer Addresses
166
Software
167
Representation of a Run Diagram
167
Terminology and Functions
168
Start/Stop Ramp Slx01.08 (RAMP)
168
Start/Stop Frequency Slx01.10 (ST_STO_F)
168
Preset Value Step Counter Slx01.00 (SV_LW)
169
Mode of Positioning Operations Slx01.14 (MODE)
170
Control Functions Slx01.07 (CONTROL)
172
Error Messages
174
Stepper Motor Module, 1 Channel
175
Connection of the Signal Lines
175
Technical Specifications
178
9 Stepper Motor Module with Processor
187
Plugging Stepper Motor Modules
188
Service Modules
188
Transfer Address Ranges
188
Assignment of Transfer Addresses
189
Software
190
Representation of a Run Diagram
190
Terminology and Functions
191
Start/Stop Ramp Slx01.08 (RAMP)
191
Start/Stop Frequency Slx01.10 (ST_STO_F)
191
Travelling Frequency Slx01.12 (MOV_FRQ)
192
Actual Position Slx00.04 (RP_LW)
192
Destination Position Slx00.00 (DP_LW)
192
Preset Value Step Counter Slx01.00 (SV_LW)
193
Mode of Positioning Operations Slx01.14 (MODE)
193
Timing Diagrams of Run Jobs
195
Control Functions Slx01.07 (CONTROL)
196
Error Messages
198
Stepper Motor Module, 2 Channels
199
Connection of the Signal Lines
199
Technical Specifications
200
Example Program
201
Appendix
211
Power Consumption of the Modules
211
Power Supply
211
DC System Supply
211
Supply of Digital Outputs and Inputs
211
Load on the Power Supply by the Modules
212
Order Specifications
213
Literature List
215
Advertisement
Advertisement
Related Products
Kuhnke KDT 635
Kuhnke KDT 633
Kuhnke KUAX 680I
Kuhnke Categories
Touch terminals
Control Panel
Controller
Servo Drives
Car Video System
More Kuhnke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL