Sign In
Upload
Manuals
Brands
Knauer Manuals
Laboratory Equipment
PLATINblue AS-1
Knauer PLATINblue AS-1 Manuals
Manuals and User Guides for Knauer PLATINblue AS-1. We have
1
Knauer PLATINblue AS-1 manual available for free PDF download: User Manual
Knauer PLATINblue AS-1 User Manual (85 pages)
Brand:
Knauer
| Category:
Laboratory Equipment
| Size: 2 MB
Table of Contents
Table of Contents
2
Fig. 47: Configuration Window for Chromgate
3
Fig. 48: Needle Flushing with Chromgate
3
Intended Use
5
Device Overview
5
Fig. 1: Autosampler AS-1, Optional with Temperature Control and Coolunit
5
Features
6
Eluents
7
Safety for Users
8
Definition of Personal and Material Damages
9
Symbols and Signs
10
Installation
11
Scope of Delivery
11
Checking the Scope of Delivery
11
Unpacking and Setup
12
Packaging and Transport
12
Contacting the Technical Support
12
Location Requirements
12
Space Requirements
12
Unpacking
13
Adjusting the Height with Additional Feet
14
Fig. 2 Platinblue AS-1 with Elevated Additional Feet
14
Fig. 3: Platinblue AS-1 Autosampler Device Foot
15
Fig. 4: Separate Device Foot
15
Fig. 5: Platinblue AS-1 Mounting Device Foot
15
Startup
16
Front View of the Device
16
Fig. 6 Front View of the Device
16
Fig. 7 Push the Door into the Interior
16
Front View with Sample Compartment
17
Fig. 8: Removing the Front Panel
17
Fig. 9: Removing the Coolunit Cover
17
Fig. 10: Front Panel of the Device with Sample Compartment
17
Rear View of the Device
18
Local Area Network and Automatic Configuration
18
Connecting the Device to a Computer
18
Fig. 11: Rear Panel of the Device
18
Configuring the LAN Settings
19
Connecting the Cables
19
Configuring the Router
20
Integrating the LAN into a Company Network
20
Fig. 12 Cabling System LAN
20
Controlling Several Systems Separately in a LAN
21
Troubleshooting for Connection Problems
21
PASA™ Loop Injection Principle
23
Injection Modes
23
Fig. 13: PASA™ Loop Injection Principle
23
Full Loop Injection
24
Fig. 14 Full Loop Injection: Initial Conditions
24
Fig. 15 Full Loop Injection: the Needle and Sample Lines Are Flushed
25
Fig. 16 Full Loop Injection: Valve Switches to LOAD Position
25
Needle Flushing
26
Air Segment for Full Loop Injection
26
Fig. 17 Full Loop Injection: the Sample Loop Is Fully Filled
26
Fig. 18 Full Loop Injection: Valve Switches to INJECT Position
26
Partial Loop Fill
27
Fig. 19: Air Segment for Full Loop Injection
27
Fig. 20: Air Segment for Partial Loop Fill
27
Fig. 21: Scheme of Initial Position for Partial Loop Fill
28
Fig. 22 Partial Loop Fill: Valve Position "Inject
28
Fig. 23 Partial Loop Fill: Aspirate Sample
29
Fig. 24 Partial Loop Fill: Valve Position "Load
29
Fig. 25 Partial Loop Fill: Inject into the Column
29
Fig. 26 Partial Loop Fill: Aspirate Flushing Solution
30
Fig. 27 Partial Loop Fill: Flush Sample and Eluent
30
Microliter Pick-Up Injection
31
Fig. 28 Microliter Pick-Up Injection: Initial Conditions
31
Fig. 29 Microliter Pick-Up Injection: Sample Line Is Filled with Eluent
31
Fig. 30 Microliter Pick-Up: Sample Is Aspirated
32
Fig. 31 Microliter Pick-Up: the Injection Volume Is Aspirated
32
Fig. 32: Microliter Pick-Up: the Sample Is Transported through
33
Fig. 33 Microliter Pick-Up: the Sample Is Transported to the Column
33
Air Segment with Μl-Pick-Up Injection
34
Air Needles
35
Standard Air Needle
35
Fig. 35: Standard Air Needle with 10 and 2 Ml Sample Vial
35
Fig. 36: Standard Air Needle with Greiner Bio-One ® Microtiter Plates
35
Choosing the Correct Air Needle
36
Fig. 37 Calculating the Correct Air Needle
36
Fig. 38: Selected Air Needles with Sample Vials
37
Fig. 39: Selected Air Needles with Greiner Bio-One ® Microtiter Plates
37
Calculation Example for Air Needle
38
Handling the Sample Vials
38
Mixing and Diluting
39
Example: Add
39
Example: MIX
39
Sample Positions in MIX Method
40
Processing in Columns
40
Fig. 40 Sample Positions in Columns
40
Processing in Rows
41
Fig. 41 Sample Positions in Rows
41
Capillary and Hose Connections
42
Connecting the Special Valve
42
Fig. 42 Connection Schematic for Capillaries and Tubing
42
Fig. 43 Connectors of Special Injection Valve
42
Connecting the Syringe
43
Tube Guide for Flushing Solution
43
Fig. 44: Syringe Connections
43
Fig. 45: Tube Guide for Flushing Solution Tube
43
Connecting the Drainage Tubing
44
Fig. 46 Connecting the Drainage Tubing
44
Connecting the Autosampler to Other Devices
45
Controlling the Autosampler with Chromatography Software
45
Checking and Configuring the Autosampler Parameters
45
Configuration Window for Chromgate
45
Autosampler Device Software
46
Needle Flushing
46
Needle Flushing with Chromgate
46
I/O Connection
47
Defining the TTL Inputs
47
Defining the Closed-Contact Output
47
Configuration of I/O Connection (9 Pins)
48
Device Test
48
Devices and Components for the Test
48
Test No. 1: Reproducibility of Sample Volume
49
Standard Setting of Autosampler
49
Method Parameters of Pump
49
Method Parameters of Autosampler
49
Method Parameters of UV Detector
50
Configuring Repeat Runs of Autosampler
50
Test No. 2: Percentage of Sample Carryover
50
Test No. 3: Linearity
50
Fig. 49 Sequence for Percentual Sample Carryover
50
Operation Qualification (OQ)
51
Test Intervals
51
Operation Qualification with Chromgate
51
Fig. 50 Settings for OQ Tests
51
Operation Qualification Report
52
Fig. 51: Operation Qualification Report
52
Maintenance and Care
53
Contacting the Technical Support
53
Maintenance Contract
53
What Maintenance Tasks Can Users Perform on the Device
53
Leaks in the Capillary Screw Fittings
54
Exchanging the Fuses
54
Changing the Valve and Rotor Seal
54
Removing the Valve and Rotor Seal
55
Fig. 52 Disassembling the Valve
55
Fig. 53 Removing the Rotor Seal
55
Fig. 54 Rotor and Rotor Seal
55
Installing the Valve
56
Replacing the Sample Needle Using Chromgate
56
Fig. 55 Installing the Injection Valve
56
Fig. 56 Sample Needle Set
56
Settings in Chromgate
57
Fig. 57 Needle Exchange, Presets in Chromgate
57
Exchanging the Sample Needle
58
Replacing the Air Needle Using Chromgate
58
Settings in Chromgate
58
Fig. 58: Sample Needle Replacement
58
Exchanging the Air Needle
59
Fig. 59 Exchanging the Air Needle
59
Replacing the Sample Loop
60
Cleaning and Caring for the Device
60
Environmental Protection
61
Disposal
61
Troubleshooting
62
Malfunctioning Valve
62
Software Faults
62
Analytical Errors
62
System Messages from Chromgate
65
Technical Data
77
Product Range
78
Device and Accessories
78
Spare Parts
78
Legal Information
80
Warranty Conditions
80
Transportation Damages
80
Declaration of Conformity
81
Abbreviations and Terminology
82
Table of Figures
83
Advertisement
Advertisement
Related Products
Knauer AZURA
Knauer AZURA SMB Pilot
Knauer AZURA SMB Lab
Knauer Azura Assistant ASM 2.1L
Knauer AZURA IJM NanoScaler
Knauer Azura IJM NanoProducer
Knauer Azura IJM SingleCore NanoProducer
Knauer Azura IJM DuoCore NanoProducer
Knauer Azura Organizer
Knauer Azura Assistant ASM 2.2L
Knauer Categories
Laboratory Equipment
Water Pump
Security Sensors
Measuring Instruments
Analytical Instruments
More Knauer Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL