Sign In
Upload
Manuals
Brands
Kidde Manuals
Control Systems
PEGAsys
Kidde PEGAsys Manuals
Manuals and User Guides for Kidde PEGAsys. We have
1
Kidde PEGAsys manual available for free PDF download: Installation, Operation And Maintenance Manual
Kidde PEGAsys Installation, Operation And Maintenance Manual (158 pages)
Intelligent Suppression Control and Fire Alarm System
Brand:
Kidde
| Category:
Control Systems
| Size: 3 MB
Table of Contents
Terms and Abbreviations
5
Table of Contents
7
List of Illustrations
12
Safety Summary
15
1 General Information
19
Introduction
19
1-1.1 System Description
19
1-1.2 System Components
19
Component Description
20
1-2.1 Central Control Module (CCM)
20
1-2.2 Display Module
20
Receiver/Transmitter Module (RX/TX)
20
Power Supply/Charger Assembly
20
1-2.5 Basic Motherboard
21
1-2.6 Multi-Loop Motherboard
21
1-2.7 Output Modules
21
1-2.7.1 Signal Output Module
22
1-2.7.2 Relay Output Module
22
Agent Release Output Module
22
City-Tie Module
22
Remote Display/Control Modules
23
ATM Series Driver Modules
23
Network Interface Card
23
1-2.11 Standby Batteries
24
1-2.12 Intelligent Loop Devices
24
1-2.12.1 Smartone Ionization Detector
24
1-2.12.2 Smartone Photoelectric Detector
24
1-2.12.3 Smartone Heat Detector
24
Smartone Detector Bases
24
Addressable Contact Input Device
24
1-2.15 Addressable Relay Output Device
25
1-2.16 Model DH-2000 Air Duct Housing
25
1-2.17 Loop Isolator Devices
25
1-2.18 ORION XT Interface Module
25
Addressable Alarmline Module
26
Addressable Signal/Sounder Module
26
System Specification
26
2 Operation
27
Introduction
27
Modes of Operation
27
Controls and Indicators
27
LCD Display
27
2-2.2 Audible Device
29
System Security
29
2-3.1 Levels of Security
29
2-3.2 Default Passwords
29
2-3.3 Entering Passwords
29
System Power-Up
29
System Menus
30
2-5.1 Menu Structure
30
Accessing the System Menus
30
Exiting the System Menus
30
Menu Functions
30
Isolate Menu Function
30
2-5.4.2 List Menu Function
33
2-5.4.3 Set Menu Function
33
2-5.4.4 Test Menu Function
33
Modes of Operation
33
2-6.1 Normal Standby Mode
33
2-6.2 Active Alarm Mode
33
2-6.2.1 Alarm Mode Indications
33
2-6.2.2 Alarm Mode User Action
33
Active Supervisory Mode
36
Supervisory Mode Indication
36
2-6.3.2 Supervisory Mode User Action
37
2-6.4 Active Trouble Mode
37
2-6.4.1 Trouble Mode Indications
37
2-6.4.2 Trouble Mode User Action
37
Printing Operation
38
System Programming
38
2-8.1 EOC Programming
38
Listing EOC Programming
38
RTC Programming
38
Listing RTC Programming
38
2-8.2.2 Enable/Disable RTC Program Line Numbers
39
2-8.3 Types of Inputs and Outputs
39
2-8.3.1 System Inputs
39
2-8.3.2 Remote Control Unit (RCU)
39
2-8.3.3 RX/TX Loops
39
2-8.3.4 System Outputs
39
2-8.3.5 System Output Modules
39
2-8.4 Addressing Output Modules
39
2-8.5 Registering Output Module Assignments
40
2-8.5.1 Listing Output Module Assignment
40
Addressing Rcus
40
2-8.7 Registering Rcus
41
2-8.7.1 Detector Registration
41
2-8.7.2 Addressable Monitor Module Registration
41
2-8.7.3 Remote Control Module Registration
42
2-8.7.4 Listing All Registered Rcus
42
DE-REGISTERING Rcus
42
3 Functional Description
43
Introduction
43
Block Diagram
43
Functional Descriptions
44
3-3.1 Central Control Module
44
Receiver/Transmitter Module (RX/TX)
45
3-3.3 Power Supply/Charger Assembly
46
3-3.4 Multi-Loop Motherboard
47
3-3.5 Signal Output Module
47
Relay Output Module
48
3-3.7 Agent Release Output Module
49
3-3.8 City-Tie Module
49
Remote Display Control Modules
50
ATM Series Driver Modules
50
Network Interface Card
50
3-3.12 Field Devices
51
3-3.13 Smartone Ionization Detector
51
3-3.14 Smartone Photoelectric Detector
51
3-3.15 Smartone Heat Detector
51
3-3.16 Addressable Contact Input Device
51
3-3.17 Addressable Relay Output Device
52
Model DH-2000 Air Duct Housing
52
Loop Isolator Devices
52
3-3.20 Pegasys Addressable Loop Module (PALM)
53
3-3.21 Addressable Alarmline Module
53
3-3.22 Addressable Signal/Sounder Module
54
4 Maintenance Procedure
55
Introduction
55
Scheduled Maintenance
55
Maintenance Procedures
55
Lamp Test
55
Loop Device Test
55
Battery Test
56
4-3.4 Walk Test
56
Walk Testing Detectors
56
Walk Test Procedure
56
4-3.5 Alarm Simulation Test (AST)
57
4-3.5.1 AST Procedure
57
Disarming and Rearming Release Circuits
57
4-4.1 Disarming Release Circuits
58
4-4.2 Arming Release Circuits
58
Powering down the System
58
4-5.1 Power-Down Procedure
58
Powering up the System
58
Power-Up Procedure
58
5 Troubleshooting and Corrective Maintenance
61
Introduction
61
Standard Fault-Isolation Techniques
61
Visual Inspection
61
Power Checks
61
Troubleshooting
61
Removal and Replacement
62
5-4.1 Required Tools
62
5-4.2 Central Control Module
62
5-4.3 RX/TX Module
62
5-4.4 Field Devices
63
6 Parts List
65
Introduction
69
7 Installation
69
Materials Required for Installation
69
Installation Procedure for Central Control Panel
69
Installation Procedure for Expansion Enclosures
69
Installation Procedure for Output Motherboard
70
Installation Procedure for Rx/Tx Module (Multi-Loop Only)
70
Installation of Output Modules
71
7-7.1 Signal Audible Output Module
71
7-7.2 Relay Output Module
72
7-7.3 Agent Release Module
72
7-7.4 City-Tie Output Module
72
7-7.5 Power Supply/Charger Assembly
72
Power Supply/Charger Assembly, Expansion Enclosure
72
7-7.7 Power Supply Communication Connections
73
Connecting AC Power
73
Install and Connect DC Power
74
7-9.1 Battery Enclosure
74
7-9.2 Batteries
74
Field Device Connection to RX/TX Module
74
Wiring the RX/TX PC Line
74
Shielded Wire to CCP
75
Output Signal Connection
76
External Power Failure Indicator Connection
76
Detector Installation
76
7-14.1 Setting and Adjusting Smoke and Heat Detector Sensitivity Procedure
77
Addressable Contact Input Device Installation
77
Addressable Relay Output Device Installation
77
Installation Checkout
78
Connection of Peripherals
78
7-18.1 Connecting a Terminal or Personal Computer
78
Connecting a Printer
78
Appendix Title
79
Power Supply Requirements
79
System Expansion
87
Releasing Applications
91
Reserved for Future Use
95
Factory Mutual Sprinkler Requirements for Pre-Action and Deluge Type Sprinkler Systems
97
Glossary
99
Display Abbreviations
101
Wiring Requirements for Pegasys Signaling Line Circuit RX/TX
103
System Drawings
107
Central Station Operation
153
Advertisement
Advertisement
Related Products
Kidde PE120CA
Kidde PE9CA
Kidde PE9
Kidde PE910UK
Kidde PE9UK
Kidde PE910
Kidde PE120
Kidde PI9000CA
Kidde P3010L
Kidde P4010ACLEDSCA
Kidde Categories
Smoke Alarm
Carbon Monoxide Alarm
Security System
Fire Alarms
Security Sensors
More Kidde Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL