Sign In
Upload
Manuals
Brands
Keysight Manuals
Accessories
E9301B
Keysight E9301B Average Power Sensor Manuals
Manuals and User Guides for Keysight E9301B Average Power Sensor. We have
2
Keysight E9301B Average Power Sensor manuals available for free PDF download: Operating And Service Manual
Keysight E9301B Operating And Service Manual (90 pages)
Power Sensors
Brand:
Keysight
| Category:
Security Sensors
| Size: 4 MB
Table of Contents
Table of Contents
16
Figures
21
Introduction
24
General Information
26
Accessories Shipped with the Instrument
26
Power Meter Requirements
26
The Keysight E-Series E9300 Power Sensors in Detail
27
Figure 1-2 Simplified Block Diagram of Diode Pair/Attenuator/Diode
27
Getting Started
29
Initial Inspection
29
Checking Power Meter Firmware and DSP Revision
29
Interconnections and Calibration
30
Recommended Calibration Interval
32
Specifications
32
Making Measurements
34
Power Meter Configuration Changes
36
Figure 2-4 Auto-Averaging Settings
36
Measuring Spread Spectrum and Multitone Signals
37
Figure 2-5 Example of an 8 Mhz Bandwidth Digital Television Signal
37
CDMA Signal Measurements
38
Figure 2-6 Wideband CDMA Error of Keysight E-Series E9300 Power
38
Figure 2-7 CDMA (IS-95A): 9Ch Fwd
38
Multitone Signal Measurements
39
Figure 2-8 Calibration Factors Versus Frequency
39
Measuring TDMA Signals
40
Electromagnetic Compatibility (EMC) Measurements
42
Measurement Accuracy and Speed
43
E9300 Operating and Service Manual
43
Table 2-1 Sensor Ranges
43
Table 2-2 Range Crossover Values
44
Specifications and Characteristics
46
Introduction
47
E9300/1/4/A Power Sensor Specifications
49
Frequency Range
49
Connector Type
49
Maximum SWR (25 °C ± 10 °C)
49
Maximum SWR (0 °C to +55 °C)
50
Maximum Power
51
Figure 3-1 Typical SWR 10 Mhz to 18 Ghz (25 °C ± 10 °C)
51
Figure 3-2 Typical SWR 9 Khz to 6 Ghz (25 °C ±10 °C) E9304A
51
Maximum DC Voltage
52
Figure 3-3 Typical Power Error Introduced in a Keysight E9304A Power
52
Power Linearity
53
Figure 3-4 Typical Power Linearity at 25 °C, after Zero and Calibration, with Associated Measurement Uncertainty
53
Additional Power Linearity Error Due to Change in
55
Temperature
55
Figure 3-5 Relative Mode Power Measurement Linearity with Keysight EPM Power Meter at 25 °C ±10 °C (Typical)
55
Switching Point
56
Zero Set, Zero Drift and Measurement Noise
57
Settling Time
57
Figure 3-6 Autofilter, Default Resolution, 10 Db Decreasing Power Step (Not Across the Switching Point)
58
Calibration Factor and Reflection Coefficient
59
Cal Factor Uncertainty (Lower Power Path, -60 to -10 Dbm)
60
Cal Factor Uncertainty (High Power Path, -10 to +20 Dbm)
60
General
61
E9300/1B and H Power Sensor Specifications
62
Frequency Range
62
Connector Type
62
Maximum SWR (25 °C ± 10 °C)
62
Maximum SWR (0 °C to +55 °C)
63
Figure 3-7 E9300B Typical SWR (25 °C ± 10 °C)
63
Maximum Power
64
Figure 3-8 E9300H Typical SWR 10 Mhz to 18 Ghz (25 °C ± 10 °C)
64
Power Linearity
65
Figure 3-9 E9300B Typical Power Linearity at 25 °C, after Zero and
65
Figure 3-10 E9300H Typical Power Linearity at 25 °C, after Zero and
66
Additional Power Linearity Error Due to Change in
67
Temperature
67
Switching Point
68
Figure 3-11 Relative Mode Power Measurement Linearity with Keysight EPM Power Meter at 25 °C ± 10 °C (Typical)
68
Calibration Factor and Reflection Coefficient
71
Figure 3-12 E9300/1B & H Autofilter, Default Resolution, 10 Db Decreasing Power Step (Not Across the Switching Point)
71
Cal Factor Uncertainty (Low Power Path)
72
Cal Factor Uncertainty (High Power Path)
73
General Characteristics
74
References
74
Service
76
General Information
77
Cleaning
77
Connector Cleaning
77
Performance Test
78
Standing Wave Ratio (SWR) and Reflection Coefficient (Rho) Performance Test
78
Table 4-3 Power Sensor SWR and Reflection Coefficient for the E9300A
78
Table 4-4 Power Sensor SWR and Reflection Coefficient for the E9301A
78
Table 4-5 Power Sensor SWR and Reflection Coefficient for the E9304A
79
Table 4-6 Power Sensor SWR and Reflection Coefficient for the E9300A
79
Table 4-7 Power Sensor SWR and Reflection Coefficient for the E9301B
79
Replaceable Parts
80
Table 4-8 Power Sensor SWR and Reflection Coefficient for the E9300H
80
Table 4-9 Power Sensor SWR and Reflection Coefficient for the Keysight E9301H
80
Service
84
Principles of Operation
84
Troubleshooting
85
Repair of Defective Sensor
85
Disassembly Procedure
85
Reassembly Procedure
86
Advertisement
Keysight
E Series
Operating And Service Manual
Keysight E9301B Operating And Service Manual (90 pages)
Power Sensors
Brand:
Keysight
| Category:
Accessories
| Size: 1 MB
Table of Contents
Table of Contents
16
Figures
21
1 Introduction
24
General Information
26
Accessories Shipped with the Instrument
26
Power Meter Requirements
26
The Keysight E-Series E9300 Power Sensors in Detail
27
Figure 1-2 Simplified Block Diagram of Diode Pair/Attenuator/Diode
27
Getting Started
29
Checking Power Meter Firmware and DSP Revision
29
Initial Inspection
29
Interconnections and Calibration
30
Recommended Calibration Interval
32
Specifications
32
2 Making Measurements
34
Power Meter Configuration Changes
36
Figure 2-4 Auto-Averaging Settings
36
Measuring Spread Spectrum and Multitone Signals
37
Figure 2-5 Example of an 8 Mhz Bandwidth Digital Television Signal
37
CDMA Signal Measurements
38
Figure 2-6 Wideband CDMA Error of Keysight E-Series E9300 Power
38
Figure 2-7 CDMA (IS-95A): 9Ch Fwd
38
Multitone Signal Measurements
39
Figure 2-8 Calibration Factors Versus Frequency
39
Measuring TDMA Signals
40
Electromagnetic Compatibility (EMC) Measurements
42
Measurement Accuracy and Speed
43
Table 2-1 Sensor Ranges
43
Table 2-2 Range Crossover Values
44
3 Specifications and Characteristics
46
Introduction
47
E9300/1/4/A Power Sensor Specifications
49
Frequency Range
49
Connector Type
49
Maximum SWR (25 °C ± 10 °C)
49
Maximum SWR (0 °C to +55 °C)
50
Maximum Power
51
Figure 3-1 Typical SWR 10 Mhz to 18 Ghz (25 °C ± 10 °C)
51
Figure 3-2 Typical SWR 9 Khz to 6 Ghz (25 °C ±10 °C) E9304A
51
Maximum DC Voltage
52
Figure 3-3 Typical Power Error Introduced in a Keysight E9304A Power
52
Power Linearity
53
Figure 3-4 Typical Power Linearity at 25 °C, after Zero and Calibration, with Associated Measurement Uncertainty
53
Additional Power Linearity Error Due to Change in
55
Figure 3-5 Relative Mode Power Measurement Linearity with Keysight EPM Power Meter at 25 °C ±10 °C (Typical)
55
Temperature
55
Switching Point
56
Settling Time
57
Zero Set, Zero Drift and Measurement Noise
57
Figure 3-6 Autofilter, Default Resolution, 10 Db Decreasing Power Step (Not Across the Switching Point)
58
Calibration Factor and Reflection Coefficient
59
Cal Factor Uncertainty (High Power Path, -10 to +20 Dbm)
60
Cal Factor Uncertainty (Lower Power Path, -60 to -10 Dbm)
60
General
61
E9300/1B and H Power Sensor Specifications
62
Frequency Range
62
Connector Type
62
Maximum SWR (25 °C ± 10 °C)
62
Maximum SWR (0 °C to +55 °C)
63
Figure 3-7 E9300B Typical SWR (25 °C ± 10 °C)
63
Maximum Power
64
Figure 3-8 E9300H Typical SWR 10 Mhz to 18 Ghz (25 °C ± 10 °C)
64
Power Linearity
65
Figure 3-9 E9300B Typical Power Linearity at 25 °C, after Zero and
65
Figure 3-10 E9300H Typical Power Linearity at 25 °C, after Zero and
66
Additional Power Linearity Error Due to Change in
67
Temperature
67
Figure 3-11 Relative Mode Power Measurement Linearity with Keysight EPM Power Meter at 25 °C ± 10 °C (Typical)
68
Switching Point
68
Calibration Factor and Reflection Coefficient
71
Figure 3-12 E9300/1B & H Autofilter, Default Resolution, 10 Db Decreasing Power Step (Not Across the Switching Point)
71
Cal Factor Uncertainty (Low Power Path)
72
Cal Factor Uncertainty (High Power Path)
73
General Characteristics
74
References
74
4 Service
76
General Information
77
Cleaning
77
Connector Cleaning
77
Performance Test
78
Standing Wave Ratio (SWR) and Reflection Coefficient (Rho) Performance Test
78
Table 4-3 Power Sensor SWR and Reflection Coefficient for the E9300A
78
Table 4-4 Power Sensor SWR and Reflection Coefficient for the E9301A
78
Table 4-5 Power Sensor SWR and Reflection Coefficient for the E9304A
79
Table 4-6 Power Sensor SWR and Reflection Coefficient for the E9300A
79
Table 4-7 Power Sensor SWR and Reflection Coefficient for the E9301B
79
Replaceable Parts
80
Table 4-8 Power Sensor SWR and Reflection Coefficient for the E9300H
80
Table 4-9 Power Sensor SWR and Reflection Coefficient for the Keysight E9301H
80
Principles of Operation
84
Service
84
Disassembly Procedure
85
Repair of Defective Sensor
85
Troubleshooting
85
Reassembly Procedure
86
Advertisement
Related Products
Keysight E9300A
Keysight E9301A
Keysight E9300B
Keysight E9300H
Keysight E9300 Series
Keysight E Series
Keysight E4412A
Keysight E4413A
Keysight E9301H
Keysight E9304A
Keysight Categories
Measuring Instruments
Test Equipment
Multimeter
Portable Generator
Power Supply
More Keysight Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL