Sign In
Upload
Manuals
Brands
KEPCO Manuals
Power Supply
ABC 25-4DM
KEPCO ABC 25-4DM Manuals
Manuals and User Guides for KEPCO ABC 25-4DM. We have
1
KEPCO ABC 25-4DM manual available for free PDF download: Operator's Manual
KEPCO ABC 25-4DM Operator's Manual (96 pages)
SWITCHING POWER SUPPLY
Brand:
KEPCO
| Category:
Power Supply
| Size: 1.96 MB
Table of Contents
Table of Contents
7
Section 1 - Introduction
15
Scope of Manual
15
General Description
15
Specifications
15
Local Control
21
Remote Control
21
Features
21
Digital Calibration
21
Overvoltage/Overcurrent Protection
21
Programmable Overvoltage/Overcurrent Delay
21
Non-Volatile Storage of Programmed Sequences or Active Settings
21
User-Defined Voltage/Current Limits
22
External Trigger/Remote On-Off Port
22
Equipment Supplied
22
Accessories
22
Safety
23
Ripple/Noise Measurement
23
Section 2 - Installation
25
Unpacking and Inspection
25
Terminations and Controls
25
Source Power Requirements
27
Cooling
27
Preliminary Operational Check
27
Installation
28
Wiring Instructions
28
Safety Grounding
28
Source Power Connections
29
D-C Output Grounding
29
Power Supply/Load Interface
29
Load Connection - General
30
Load Connection Using Local Sensing
31
Load Connection Using Remote Sensing
32
Operating Configuration
32
Section 3 - Operation
33
General
33
Remote On/Off
33
Local Mode Operation
33
Front Panel Keypad and LCD
33
Command Entry Status
33
Data Entry Status
33
Display (LCD)
34
Keypad Functions
34
Turning the Power Supply on
36
Setting Local Mode
37
Adjusting LCD Contrast
37
Enabling/Disabling Audible Beeps
37
Enabling/Disabling DC Output Power
37
Power up Digital DC Output Control
37
Reset
37
Setting Output Voltage or Current
38
Programming Techniques to Optimize Power Supply Performance
38
Setting Overvoltage or Overcurrent Protection
39
Changing Protection Delay
39
Changing Maximum Voltage or Current Value
39
Storing Power Supply Output Settings
40
Recalling Stored Output Settings
40
Local Mode Programming of the Power Supply
40
Creating or Modifying a Program (Program Edit Mode)
40
Modifying Programmed Time Interval
41
Running a Program
41
Stepping through a Program
41
Cycling a Program
41
Running a Program Once
41
Stopping a Program
43
Stopping a Running Program
43
Sample Program
43
Calibration
43
Remote Mode Programming
43
DCL Control
44
IEEE 488 (GPIB) Bus Operation
44
IEEE 488 (GPIB) Bus Protocol
44
Changing the GPIB Address
44
ABC VISA Instrument Driver
46
RS232-C Operation
46
Setting RS 232 Baud Rate
47
Serial Interface
47
RS 232 Implementation
47
Echo Mode
48
Prompt Method
48
XON XOFF Method
49
Isolating RS 232 Communication Problems
49
SCPI Programming
49
SCPI Messages
50
Common Commands/Queries
50
SCPI Subsystem Command/Query Structure
50
Abort Subsystem
50
Display Subsystem
50
Initiate Subsystem
50
LIST Subsystem
50
Measure Subsystem
50
Output Subsystem
51
Protection Subsystem
51
Status Subsystem
51
Trigger Subsystem
51
Source:]Voltage and [Source:]Current Subsystems
51
Calibrate Subsystem
51
Instrument Subsystem
51
System Subsystem
52
Program Message Structure
52
Keyword
52
Keyword Separator
54
Query Indicator
54
Data
54
Data Separator
54
Message Unit Separator
54
Root Specifier
54
Message Terminator
54
Understanding the Command Structure
55
Program Message Syntax Summary
56
SCPI Program Examples
57
Operator Maintenance
57
Section 4 - Calibration
59
General
59
Equipment Required
59
Calibration Procedures
59
Voltage Calibration
60
Current Calibration
60
Changing the Calibration Password
61
Restoring Previous Calibration Values
62
Restoring Factory Calibration Values
62
Setting Factory Calibration Values
62
Calibration Storage
62
Appendix A - Ieee 488.2 Command/Query Definitions
65
CLS - Clear Status Command
65
ESE - Standard Event Status Enable Command
65
ESE? - Standard Event Status Enable Query
66
ESR? - Event Status Register Query
66
IDN? - Identification Query
66
OPC - Operation Complete Command
66
OPC? - Operation Complete Query
67
OPT? - Options Query
67
RCL - Recall Command
67
RST - Reset Command
68
SAV - Save Command
69
SRE - Service Request Enable Command
69
SRE? - Service Request Enable Query
69
STB? - Status Byte Register Query
69
TRG - Trigger Command
70
TST? - Self Test Query
70
Appendix B - Scpi Command/Query Definitions
71
Introduction
71
Abort Command
72
Calibrate:current:level Command
73
Calibrate:current[:Data] Command
73
Calibrate:password Command
74
Calibrate:save Command
74
Calibrate:status Command
74
Calibrate:status? Query
74
Calibrate:voltage:level Command
74
Calibrate:voltage[:Data] Command
74
Calibrate:zero Command
75
Display:contrast Command
75
Display:contrast? Query
75
Display:mode Command
75
Display:mode? Query
76
Display:text Command
76
Display:text? Query
76
Initiate[:Immediate] Command
76
Initiate:continuous Command
76
Initiate:continuous Query
76
Instrument:state Command
76
List:current Command
77
Sour:]List:current? Query
77
Advertisement
Advertisement
Related Products
KEPCO ABC-DM Series
KEPCO ABC 10-10DM
KEPCO ABC 15-7DM
KEPCO ABC 36-3DM
KEPCO ABC 60-2DM
KEPCO ABC 125-1DM
KEPCO ATE 15-25
KEPCO ATE 36-30
KEPCO ATE 6-100
KEPCO ATE 150-1.5
KEPCO Categories
Power Supply
Adapter
Battery Charger
Recording Equipment
Protection Device
More KEPCO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL