Johnson Controls YORK HYP1100A Drive Manuals
Manuals and User Guides for Johnson Controls YORK HYP1100A Drive. We have
1
Johnson Controls YORK HYP1100A Drive manual available for free PDF download: Operation Manual
Johnson Controls YORK HYP1100A Operation Manual (24 pages)
LIQUID COOLED OPTISPEED COMPRESSOR SPEED DRIVE
Brand:
Johnson Controls
| Category:
DC Drives
| Size: 0 MB
Table of Contents
TABLE 1 - VSD Part Numbers and Descriptions
4
Table of Contents
5
Section 1 - General Information
7
Optispeed Compressor Drive Overview
7
Optispeed Compressor Drive Features
7
Optispeed Compressor Drive Details
8
FIGURE 1 - HYP1100A / HYP1300A HP Complete Drive Cabinet
10
FIGURE 2 - Left Side of HYP1100A / HYP1300A HP Drive Cabinet
11
FIGURE 3 - Right Side of HYP1100A / HYP1300A HP Drive Cabinet
12
FIGURE 4 - Drive Logic Board
13
FIGURE 5 - Rectifier Side of the Power Unit HYP1100A and HYP1300A
13
Drive and Chiller Operation
14
Optispeed Compressor Drive Control System Overview
14
Section 2 - Safety Shutdowns
15
VSD - DC BUS Lockout - Do Not Cycle Power
15
VSD - DC BUS Pre-Regulation Lockout
15
VSD - Ground Fault
15
VSD - High Phase a Input Baseplate Temperature
15
VSD - High Phase B Input Baseplate Temperature
15
TABLE 2 - Safety Shutdowns Message
15
VSD - High Phase C Input Baseplate Temperature
16
VSD - High Phase a Motor Baseplate Temperature
16
VSD - High Phase B Motor Baseplate Temperature
16
VSD - High Phase C Motor Baseplate Temperature
16
VSD - High Total Demand Distortion
16
VSD - Input Current Overload
16
VSD - Input DCCT Offset Lockout
16
VSD - Inverter Program Fault
16
VSD - Line Voltage Phase Rotation
16
VSD - Logic Board Hardware
16
VSD - 105% Motor Current Overload
17
VSD - Motor Current THD Fault
17
VSD - Phase a Input DCCT
17
VSD - Phase B Input DCCT
17
VSD - Phase C Input DCCT
17
VSD - Phase a Motor DCCT
17
VSD - Phase B Motor DCCT
17
VSD - Phase C Motor DCCT
17
VSD - Phase Locked Loop
17
VSD - Precharge Lockout
17
Section 3 - Cycling Shutdowns
19
VSD - DC Bus Pre-Regulation
19
VSD - High DC Bus Voltage
19
VSD - High Internal Ambient Temperature
19
TABLE 3 - Cycling Shutdown Message
19
VSD - High Phase a Input Current
20
VSD - High Phase B Input Current
20
VSD - High Phase C Input Current
20
VSD - High Phase a Motor Current
20
VSD - High Phase B Motor Current
20
VSD - High Phase C Motor Current
20
VSD - Initialization Failed
20
VSD - Invalid Setpoints
20
VSD - Logic Board Power Supply
20
VSD - Logic Board Processor
20
VSD - Low Phase C Input Baseplate Temperature
21
VSD - Low Phase a Motor Baseplate Temperature
21
VSD - Low Phase B Motor Baseplate Temperature
21
VSD - Low Phase C Motor Baseplate Temperature
21
VSD - Not Running
21
VSD - Phase a Input DCCT Offset
21
VSD - Phase B Input DCCT Offset
21
VSD - Phase C Input DCCT Offset
21
VSD - Phase a Input Gate Driver
21
VSD - Phase B Input Gate Driver
21
VSD - Precharge - Low DC BUS Voltage 2
22
VSD - Run Signal
22
VSD - Serial Receive
22
VSD Shutdown - Requesting Fault Data
22
VSD - Single Phase Input Power
22
VSD - Stop Contacts Open
22
Vsd Frequently Asked Questions
23
Advertisement
Advertisement
Related Products
Johnson Controls YORK HYP1300A
Johnson Controls York AYK550
Johnson Controls York AYK550-UH
Johnson Controls YORK HYP1100
Johnson Controls YORK HYP1278
Johnson Controls YORK HYP1300
Johnson Controls YORK HYP0490
Johnson Controls YORK HYP0612
Johnson Controls YORK HYP0730
Johnson Controls YORK HYP0744