Sign In
Upload
Manuals
Brands
ISA Manuals
Test Equipment
MC5
User Manuals: ISA MC5 Leak Test Equipment
Manuals and User Guides for ISA MC5 Leak Test Equipment. We have
1
ISA MC5 Leak Test Equipment manual available for free PDF download: User Manual
ISA MC5 User Manual (170 pages)
MULTIFUNCTION CALIBRATOR
Brand:
ISA
| Category:
Test Equipment
| Size: 3 MB
Table of Contents
Table of Contents
3
Introduction
10
About this Manual
10
Typographical Conventions
11
Unpacking and Inspection
11
MC5 Hardware
12
Operational Sections and Connections
12
The Upper Panel
13
The Connectors on the Left Side of MC5
14
The Front Panel
15
Memory
18
Batteries
19
About the Charger and the Charging Procedure
20
Removing/Replacing the Battery Pack
21
Support for Table Top Use
22
The Wrist Strap and the Neck Support Strap
22
The Optional Carrying Case
22
MC5 Firmware
23
General Description
23
Startup Procedure
23
Basic Mode
24
Maintenance
24
Calibration Mode
24
Help Function
25
Printing
25
The User Interface
26
The Status Bar
26
The Function Key Bar
27
Menus
27
The Display Area
28
Mc5’S Modularity and Options
32
Hardware Modules/Options
32
Other Connectable Devices
33
Firmware Options
33
Safety
34
Certifications and Compliances (EC Declaration of Conformity)
34
Safety Precautions and Warnings
35
General Warnings
35
Warnings Concerning the Use of Electrical Modules (E and ET)
36
General Warnings Concerning Pressure Measurement
36
Warnings Concerning High Pressure
37
Service
38
Firmware Update
38
Recalibrating MC5
38
The Battery Charger
38
Cleaning MC5
39
Cleaning the Contacts of the Internal Reference Junction Module
39
Part B, Startup and Basic Operation
41
Starting MC5
42
Startup Procedure
42
Basic Mode, Defined
43
Measuring
45
Pressure Measurement
47
Using Internal Modules
47
Using External Modules
47
Zeroing a Pressure Module
48
Current Measurement
49
External Supply
49
Internal Supply
49
Voltage Measurement
50
Measuring Low Voltages
50
Measuring Voltages up to ±50 V
51
Resistance Measurement
52
Switch State Sensing
53
Limit Switch Test
54
Performing the Limit Switch Test
54
Frequency Measurement
56
Pulse Counting
57
RTD Measurement (Temperature)
58
Thermocouple Measurement (Temperature)
59
Internal Reference Junction
59
External Reference Junction
59
Special Measurements
61
Mathematical Special Measurements
62
Minimum Value
62
Maximum Value
62
Min/Max Value
62
Rate of Change
62
Special Filtering and Resolution
63
Deviation Measurement
63
Special Measurements Using Two Ports Simultaneously
64
Difference Measurement
64
Redundant Measurement
65
Generating/Simulating
66
General
66
Changing the Value of the Generated/Simulated Signal
67
Current Generation
68
Using the ET Module’S Output Terminals
68
Using the E Module’S Output Terminals
68
Voltage Generation
70
Generating Voltages up to ±12 V
70
Low Voltage Generation
70
Frequency Generation
72
Pulse Generation
73
RTD and Resistance Simulation
74
Thermocouple Simulation
75
Internal Reference Junction
75
External Reference Junction
75
Special Generations
77
Opening the Step or Ramp Configuration Window
77
Stepping
78
Ramping
79
Alarm Limit Settings
81
Part C, Advanced Operation and Configurations
83
Configuring the Calibrator
84
Settings
84
Setting Time and Date
86
Advanced Utilities
87
Measuring the Environment Temperature with the ENV Sensor
87
Display Mode Settings
88
Scaling
89
Displaying Values in Percentage
90
Displaying Error Values
90
Transmitter/Switch Simulation
91
Transmitter Simulation
92
Switch Simulation
93
Data Logging
94
General
94
Configuring
94
Starting the Data Log
95
Viewing the Results
96
Transferring the Results to a Personal Computer
96
Generating Signals Using External Devices
97
Controlling the External Device in Basic Mode
98
Pressure Controller Settings
99
Temperature Controller Settings
100
Printing
101
Additional Information
102
Things to Consider When Measuring Pressure
103
General
103
Pressure Type
103
Pressure Modules and Their Naming Conventions
104
Square Rooting
104
Thermocouple Measurement/Simulation, Connections and Troubleshooting
105
Internal Reference Junction
105
External Reference Junction
106
Error Situations
108
Resistance and RTD Measurement, Connections
109
4-Wire System
109
Using a Compensation Loop
110
2-Wire System
110
Current Measurement Parallel to a Test Diode, Connections
111
Parallel Functions in MC5
112
Part D, Calibration
113
General
114
Phases of Instrument Calibration
115
As Found Calibration
116
Adjustment
116
As Left Calibration
117
Required Modules for Different Input/Output Signal Combinations
118
Calibrating an Instrument
120
Selecting the Instrument to be Calibrated
120
The Instrument Window
121
A Calibration Procedure Using MC5
122
About Manual Calibration
124
About Automatic Calibration
124
Autocapture Feature
125
Examples of Instrument Calibration
125
Pressure Transmitters and Sensors
126
Temperature Sensors
128
Temperature Indicators and Recorders
130
Electrical Limit Switches
132
Using External Devices in Calibration Mode
134
Maintaining Mc5’S Instrument Database
136
Adding New Instruments
136
Editing Instrument Data
137
General Data Page
137
Instrument Input Page
138
Instrument Output Page
138
Calibration Settings Page
139
Calibration Instructions Page
140
Deleting Instruments
140
Viewing Calibration Results
141
Calibration Result Windows
142
How to Choose Which Calibration Run Is Viewed
142
Deleting Calibration Results
142
Appendix
143
Appendix 1, User Guide for Mc5 Hart Option
144
User Guide for MC5 HART Option
144
General
145
MC5 and HART
145
HART Instruments and Beamex's Calibration Database Software
145
Connecting MC5 and a HART Instrument
146
Supply from the Calibrator
146
External Supply
146
Using MC5 as a HART Communicator
147
Test Diode Connections
147
HART Communication Settings
148
HART and Mc5'S Basic Mode
149
Connecting to a HART Instrument
149
Disconnecting a HART Instrument
150
Device Information
150
Device Settings
151
Trimming a HART Instrument in Basic Mode
151
Adding a HART Instrument to Mc5'S Instrument Database
153
Calibrating a HART Instrument
154
Selecting the Instrument to be Calibrated
154
The Calibration Procedure
155
Trimming a HART Instrument in Calibration Mode
155
Technical Data
158
MC5 General Specifications
159
Modules
160
Pressure Modules (INT & EXT)
160
Temperature Electrical Module (ET)
161
RTD Measurement and Simulation
161
Thermocouple Measurement and Simulation
162
Reference Junction Module (RJ)
162
Electrical Module (E)
163
Quick Guide for the MC5 Datalog Viewer
164
Index
168
Advertisement
Advertisement
Related Products
ISA MILLENIUM ST
ISA MILLENIUM LX
ISA MILLENNIUM MY2019
ISA METRO 412100981000
ISA METRO 412100982000
ISA METRO 412100984000
ISA Millennium LX Gelato
ISA Millennium ST Pastry
ISA MARIN 340
ISA MARIN 470
ISA Categories
Commercial Food Equipment
Refrigerator
Test Equipment
Display Case
Freezer
More ISA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL