Sign In
Upload
Manuals
Brands
IPG Photonics Manuals
Industrial Equipment
LC 340.01-A.3.5/6
IPG Photonics LC 340.01-A.3.5/6 Manuals
Manuals and User Guides for IPG Photonics LC 340.01-A.3.5/6. We have
1
IPG Photonics LC 340.01-A.3.5/6 manual available for free PDF download: Operating Manual
IPG Photonics LC 340.01-A.3.5/6 Operating Manual (54 pages)
Laser Chiller
Brand:
IPG Photonics
| Category:
Industrial Equipment
| Size: 1 MB
Table of Contents
Table of Contents
3
Index of Contents
3
General Information
4
Safety and Accident Prevention
5
Safety Symbols
6
Technical Data
7
Pump Charts
10
Transport
12
Maintenance Room/Installation Room
15
Place of Installation
15
Wall Distance
15
First Start-Up of the Chiller
15
Connecting the Chiller with the Laser
16
Charging of the Cooling System
17
Cooling Water Specification
17
Cooling Water Additives
17
Start up Laser Circuit
17
Checking the Electrical Rotating Field
19
Electrical Connection
19
Ventilating the Pump
20
Piping and Instruments Diagram
21
Refrigerant Module
22
Hydraulic Module
25
Laser Cooling Circuit
25
Optic Cooling Circuit
26
Switching on
28
Intended Usage of the Chiller
28
Adjusting and Maintenance Work
28
Switching off
29
Adjusting Work
29
Bypass Valve
29
Changing the Connecting Voltage
30
Maintenance Work
31
Inspection
31
Pumps
31
DI-Cartridge
32
Changing the Air Filter
32
Checking the Refrigerant Filling
33
Cooling Water of the Laser Circuit
34
Warnings and Alarms
34
Water Level Warning
34
Water Temperature Warning
34
Water Pressure Warning
36
DI Water Conductivity
37
Low Pressure Compressor Is Near Limit
37
Alarm Messages
38
Interruption of Operation
38
Water Level Alarm
39
Water Temperature Alarm
40
Water Pressure Alarm
41
DI Water Conductivity Alarm
42
Overcurrent Alarm
42
Laser Cooling Circuit – Pump over Current
42
Optic Cooling Circuit – Pump over Current
43
Laser Cooling Circuit – over Current Tank Heater
43
Refrigerant Circuit – over Current Compressor
44
Optic Cooling Circuit – over Current Tank Heater
44
Sensor Failed Alarm
45
Refrigerant Circuit – over Current Fan
45
Laser Cooling Circuit – Error Temperature Sensor
45
Optic Cooling Circuit – Error Temperature Sensor
46
Laser Cooling Circuit – Error Pressure Sensor
46
Optic Cooling Circuit – Error Pressure Sensor
46
Refrigerant Circuit – Error High Pressure Sensor
47
Refrigerant Circuit – Error Low Pressure Sensor
47
Optic Cooling Circuit – Error Conductivity Sensor
47
Low Pressure Compressor Fault Alarm
48
High Pressure Compressor Fault Alarm
48
Electric Phase Connection Wrong
49
Reset of the Alarm
49
Disruption in Operation of the Compressor
50
Disruption in Operation of the Pump
50
Technical Data Pumps
51
Disruption in Operation of the Fan
52
Electrical Drawing
53
Advertisement
Advertisement
Related Products
IPG Photonics P30-010226
IPG Photonics P30-010300
IPG Photonics Scanner Series
IPG Photonics YLR-5000
IPG Photonics YLR-5000-WC
IPG Photonics Categories
Industrial Equipment
Wire Feeders
Welding System
Amplifier
Measuring Instruments
More IPG Photonics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL