Sign In
Upload
Manuals
Brands
IOtech Manuals
Recording Equipment
Digital488
User Manuals: IOtech Digital488 Measurement Equipment
Manuals and User Guides for IOtech Digital488 Measurement Equipment. We have
2
IOtech Digital488 Measurement Equipment manuals available for free PDF download: Instruction Manual, Manual
IOtech Digital488 Instruction Manual (83 pages)
IEEE 488 to Digital Interface
Brand:
IOtech
| Category:
Recording Equipment
| Size: 2 MB
Table of Contents
Fcc Statement
2
Limitation of Liability
2
Warranty Information
2
Table of Contents
5
Introduction
9
Section1
9
General Description
9
Available Accessories1.2
10
Specifications
11
Abbreviations
15
Getting Started
17
Inspection
17
Configuration
17
IEEE Bus Output Terminator Selection
19
Digital Input/Output Ports
20
Logic Levels
20
Digital I/O Port Pin Outs
20
Control Lines
22
Clear
22
Data Strobe
23
External Data Ready
23
Inhibit
24
Trigger
25
Service
25
IEEE 488 Bus Implementation
25
My Talk Address (MTA)
26
My Listen Address (MLA)
27
Device Clear (DCL and SDC)
27
Group Execute Trigger (GET)
27
Interface Clear (IFC)
28
Serial Poll Enable (SPE)
28
Serial Poll Disable (SPD)
28
Unlisten (UNL)
28
Untalk (UNT)
28
Installation
29
Command Descriptions
31
Bit Set (An)
32
Bit Clear (Bn)
33
Bus Input/Output (Gn)
34
Command Descriptions
34
Configure Cn
35
Data (D
36
Data Ready (Rn)
38
End or Identify (Kn)
39
Execute (X)
40
Format Fn
41
Handshake Hn
48
Inhibit (Qn)
49
Invert (In)
50
Port Pn
51
Service Request Mask (Mn)
52
Serial Poll Status Byte
54
Status un
56
Terminator Yn
59
Test (T0)
60
IEEE 488 Primer
61
History
61
General Structure
61
Send It to My Address
64
Bus Management Lines
64
Attention (ATN)
64
Interface Clear (IFC)
65
Remote Enable (REN)
65
End or Identify (EOI)
65
Service Request (SRQ)
65
Handshake Lines
66
Data Valid (DAV)
66
Not Ready for Data (NRFD)
66
Not Data Accepted (NDAC)
66
Data Lines
67
Multiline Commands
67
Go to Local (GTL)
67
Listen Address Group (LAG)
68
Unlisten (UNL)
68
Talk Address Group (TAG)
68
Untalk (UNT)
68
IEEE 488 Primer
68
Local Lockout (LLO)
68
Device Clear (DCL)
68
Selected Device Clear (SDC)
69
Serial Poll Disable (SPD)
69
Serial Poll Enable (SPE)
69
Group Execute Trigger (GET)
69
Take Control (TCT)
69
Secondary Command Group (SCG)
69
Parallel Poll Configure (PPC)
70
Parallel Poll Unconfigure (PPU)
70
More on Service Requests
70
Serial Poll
71
Parallel Poll
71
Service Information
73
Factory Service
73
Theory of Operation
73
Digital488 Parts List
77
Advertisement
IOtech Digital488 Manual (64 pages)
IEEE 488 to Digital I/O Interface
Brand:
IOtech
| Category:
Recording Equipment
| Size: 4 MB
Table of Contents
Table of Contents
4
Introduction
6
General Description
6
Digital488
6
Digital488/32/Oem
6
Available Accessories
7
Specifications
7
Digital488 Specifications
7
Digital I/O
7
Ieee 488
8
General
8
Digital488/32/Oem Specifications
9
Digital I/O
9
Ieee 488
9
General
10
Abbreviations
11
Getting Started
12
Inspection
12
Configuration
12
IEEE 488 Address Selection
13
IEEE 488 Bus Output Terminator Selection
14
Digital Input/Output Ports
14
Logic Levels
14
Digital I/O Port Pin Outs
15
Control Lines
16
Clear
16
Data Strobe
16
External Data Ready [EDR]
17
Inhibit
17
Trigger
17
Service
18
IEEE 488 Bus Implementation
18
My Talk Address (MTA)
18
My Listen Address (MLA)
19
Device Clear (DCL and SDC)
19
Group Execute Trigger (GET)
19
Interface Clear (IFC)
19
Serial Poll Enable (SPE)
19
Serial Poll Disable (SPD)
19
Unlisten (UNL)
19
Untalk (UNT)
19
Installation
20
Command Descriptions
22
Bit Set an
22
Bit Clear Bn
22
Bus Input/Output Gn
23
Configure Cn
23
Data Ready Rn
25
End or Identify (EOI) Kn
25
Execute X
26
Format Fn
26
F0 Format- ASCII Hexadecimal
26
F1 Format - ASCII Character
27
F2 Format - ASCII Binary
28
F3 Format - ASCII Decimal
28
F4 Format - Binary
29
F5 Format - High Speed Binary
29
Handshake Hn
30
Inhibit Qn
30
Invert in
30
Service Request Mask (SRQ) Mn
31
Serial Poll Status Byte
32
Status un
33
Terminator Yn
35
IEEE 488 Primer
38
History
38
General Structure
38
Send It to My Address
40
Bus Management Lines
40
Attention (ATN)
40
Interface Clear (IFC)
40
Remote Enable (REN)
40
End or Identify (EOI)
40
Service Request (SRQ)
40
Handshake Lines
41
Data Valid (DAV)
41
Not Ready for Data (NRFD)
41
Not Data Accepted (NDAC)
41
Data Lines
41
Multiline Commands
42
Go to Local (GTL)
42
Listen Address Group (LAG)
42
Unlisten (UNL)
42
Talk Address Group (TAG)
42
Untalk (UNT)
42
Local Lockout (LLO)
42
Device Clear (DCL)
42
Selected Device Clear (SDC)
42
Serial Poll Disable (SPD)
42
Parallel Poll Configure (PPC)
43
Parallel Poll Unconfigure (PPU)
43
More on Service Requests
43
Serial Poll
43
Parallel Poll
43
Service Information
44
Factory Service
44
Theory of Operation
44
Digital488 Mother Board
45
Digital488 I/O Board
47
Digital488/32/Oem
48
Digital488/Oem
49
Advertisement
Related Products
IOtech Digital488/80A
IOtech Digital488HS/32
IOtech Digital488/32/OEM
IOtech Digital488OEM
IOtech Personal Daq/54
IOtech Personal Daq/55
IOtech Personal Daq/56
IOtech Personal Daq/3001
iotech DaqOEM/2001
iotech DaqBook/2005
IOtech Categories
Measuring Instruments
Recording Equipment
Computer Hardware
Control Unit
Controller
More IOtech Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL