Table of Contents
Table of Contents
4
Model Number Descriptions - 3 to 10 Tons (T/Y)
7
Model Number Descriptions - 3 to 5 Tons (T/Y - 17 Plus)
10
Model Number Notes
11
General Information
12
Unit Inspection
12
Storage
12
Unit Nameplate
12
Compressor Nameplate
12
Microchannel Coil Barcode ID
12
Unit Description
12
Economizer Control Actuator (Optional)
12
System Input Devices and Functions
13
Low Pressure Control
14
High Pressure Control
14
Power Exhaust Control (Optional)
14
Lead/Lag Control (Dual Circuit Only)
14
Evaporator Frost Control
15
Discharge Line Temp Switch (DLTS)
16
Smoke Detector Sensor (Optional)
16
Phase Monitor
16
Single Zone Variable Air Volume / Displacement Ventilation (Optional)
16
Human Interface - 5 Inch Color Touchscreen (Optional)
16
Pre-Installation
17
Dimensions and Weights
18
Unit Clearances
18
Installation
27
Foundation
27
Horizontal Units
27
Ductwork
27
Roof Curb
28
Downflow
28
Rigging
29
General Unit Requirements
30
Factory Installed Economizer
30
Temperature Limit Switch Usage for Gas
30
Heat Units
30
Horizontal Discharge Conversion (3 to 5 Ton Units)
31
TCO1 Instructions
32
Horizontal Discharge Conversion (6 to 10 Ton Units)
32
TCO1 Instructions
33
Unit Model Number
33
Return Air Smoke Detector
34
Air-Fi® Wireless Communication Interface
34
Main Electrical Power Requirements
35
Through-The-Base Gas Installation
35
Requirements for Gas Heat
36
Condensate Drain Configuration
36
Filter Installation
37
Field Installed Power Wiring
37
Main Unit Power
37
Standard Wiring
38
Optional TBUE Wiring (Through-The-Base Electrical Option)
38
Field-Installed Control Wiring
38
Control Power Transformer
39
Controls Using 24 Vac
39
Controls Using DC Analog Input/Outputs (Standard Low Voltage Multi Conductor Wire)
39
DC Conductors
40
Space Temperature Averaging (Reliatel™ Only)
44
Pre-Start
47
Voltage Imbalance
47
Electrical Phasing (Three Phase Motors)
47
Compressor Crankcase Heaters (Optional)
48
Reliatel™ Controls
48
Test Modes
49
Reliatel™ Controls
49
Electromechanical Controls Test
50
Procedure
50
Unit Start-Up
51
Sequence of Operation
51
Reliatel™ Controls
51
Reliatel™ Controls - Constant Volume (CV)
51
Reliatel™ Control Cooling Without an Economizer
51
Three-Stages of Cooling
51
Reliatel™ Control Evaporator Fan Operation (for Gas Units)
51
Reliatel™ Control Evaporator Fan Operation (for Cooling Only Units)
52
Low Ambient Operation
52
Multi-Speed Indoor Motor
52
Fan Output
52
Multi-Zone VAV Sequence of Operation
52
Supply Air Pressure Control
52
Supply Air Static Pressure Limit
53
Supply Air Temperature Controls
53
Supply Air Setpoint Reset
53
Zone Temperature Control
53
Variable Air Volume Applications (Single Zone VAV)
54
Discharge Air Cool Setpoint Adjustment
54
Reliatel™ Control Cooling with an Economiz
54
Reliatel™ Control Dehumidification
55
Dehumidification Coil Purge Cycle
55
Reliatel™ Control Cooling with an Economiz
55
Economizer Set-Up
56
Reliatel™ Control Heating Operation (for Cooling Only Units)
56
Reliatel™ Control Heating Operation (for Gas Units)
56
Ignition Module
56
Drain Pan Condensate Overflow Switch (Optional)
57
Electromechanical Controls
57
Electromechanical Control Cooling Without an Economizer
57
Electromechanical Control Evaporator Fan Operation (for Gas Units)
57
Electromechanical Evaporator Fan Operation (for Cooling Only Units)
57
Economizer Set-Up
58
Electromechanical Control Cooling with an Economizer
58
Electromechanical Control Heating Operation (for Cooling Only Units)
58
Electromechanical Control Heating Operation (for Gas Units)
58
Ignition Module Low, Medium and High Heat
58
Drain Pan Condensate Overflow Switch (Optional)
59
Verifying Proper Air Flow
59
Units with 5-Tap Direct Drive Indoor Fan
59
Units with Belt Drive Indoor Fan
60
Units with Direct Drive Indoor Fan - Electromechanical Control
60
Reliatel™ Units with Direct Drive Indoor Fan
60
Plus Units with the Constant CFM Direct Drive Indoor Fan
62
Variable Air Volume Applications (Traditional VAV)
62
Supply Duct Static Pressure Control
63
Traditional VAV Standalone Operation
63
Supply Air Temperature Reset
63
Return Air Smoke Detector
64
Economizer Start-Up
64
Compressor Start-Up
65
Dehumidification Option
66
Gas Heat Units
66
Final System Setup
66
Maintenance
67
Fan Belt Adjustment - Belt Drive Units
67
Monthly Maintenance
68
Filters
68
Return Air Smoke Detector Maintenance
68
Condensate Overflow Switch
68
Cooling Season
68
Heating Season
68
Coil Cleaning
69
Annual Maintenance
70
Troubleshooting
71
Reliatel™ Control
71
System Status Checkout Procedure
71
Method 1
71
Resetting Cooling and Ignition Lockouts
73
Zone Temperature Sensor (ZTS) Service Indicator
73
Clogged Filter Switch
73
Fan Failure Switch
73
Condensate Overflow Switch
73
Zone Temperature Sensor (ZTS) Tests
73
Test 1 - Zone Temperature Thermistor (ZTEMP)
73
Test 2 - Cooling Set Point (CSP) and Heating Set Point (HSP)
73
Test 3 - System Mode and Fan Selection
73
Test 4 - LED Indicator Test
74
COOL and SERVICE)
74
Relative Humidity Sensor Test
74
Programmable and Digital Zone Sensor Test
74
Reliatel™ Refrigeration Module (RTRM) Default Chart
74
Unit Operation Without a Zone Sensor
74
Unit Economizer Control (ECA) Troubleshooting Reliatel™ Control
74
Electromechanical Control
75
Unit Economizer Control (ECA) Test Procedures Electromechanical Control
77
Troubleshooting Procedures for Direct Drive Plenum Fan
77
Unit Wiring Diagrams Numbers
78
Limited Warranty
81
Combination Gas Electric Air Conditioner
81
YCD, YCH, YSC and YHC (Parts Only)
81
Models Less than 20 Tons for Commercial Use
81
Advertisement
Ingersoll-Rand YHC072E Installation, Operation And Maintenance Manual (74 pages)
Rooftop Air Conditioner
Brand:
Ingersoll-Rand
| Category:
Air Conditioner
| Size: 10 MB
Table of Contents
Table of Contents
4
Model Number Descriptions - 3 to 10 Tons (T/Y)
6
Model Number Notes
7
Model Number Descriptions - 3 to 5 Tons (T/Y - 17 Plus)
9
Model Number Notes
10
Reliatel™ Units with Direct Drive Indoor Fan (10 Tons Standard Efficiency, 6(074) to
10
General Information
11
Unit Inspection
11
Storage
11
Unit Nameplate
11
Compressor Nameplate
11
Microchannel Coil Barcode ID
11
Unit Description
11
Economizer Control Actuator (Optional)
11
System Input Devices & Functions
12
Low Pressure Control
13
High Pressure Control
13
Power Exhaust Control (Optional)
13
Lead/Lag Control (Dual Circuit Only)
13
Evaporator Frost Control
14
Discharge Line Temp Switch (DLTS)
15
Smoke Detector Sensor (Optional)
15
Phase Monitor
15
Single Zone Variable Air Volume / Displacement Ventilation (Optional)
15
Human Interface - 5 Inch Color Touchscreen (Optional)
15
Unit Dimensions
16
Installation
24
Pre-Installation
24
Procedure
24
Precautionary Measures
24
Foundation
26
Horizontal Units
26
Ductwork
27
Roof Curb
28
Downflow
28
Rigging
29
General Unit Requirements
29
Factory Installed Economizer
30
Temperature Limit Switch Usage for Gas Heat Units
30
Horizontal Discharge Conversion
31
Units)
31
TCO1 Instructions
31
Horizontal Discharge Conversion
32
Units)
32
TCO1 Instructions
33
Return Air Smoke Detector
33
Unit Model Number
33
Air-Fi™ Wireless Communication Interface
34
Main Electrical Power Requirements
34
Through-The-Base Gas Installation
35
Requirements for Gas Heat
35
Condensate Drain Configuration
36
Filter Installation
36
Field Installed Power Wiring
37
Main Unit Power
37
Standard Wiring
37
Optional TBUE Wiring (Through-The-Base Electrical Option)
37
Field-Installed Control Wiring
38
Control Power Transformer
38
Controls Using 24 VAC
38
Controls Using DC Analog Input/Outputs (Standard Low Voltage Multi Conductor Wire)
39
DC Conductors
39
Space Temperature Averaging
44
Pre-Start
47
Voltage Imbalance
47
Electrical Phasing (Three Phase Motors)
47
Compressor Crankcase Heaters (Optional)
48
Reliatel™ Controls
48
Test Modes
49
Reliatel™ Controls
49
Electromechanical Controls Test
50
Procedure
50
Unit Start-Up
51
Verifying Proper Air Flow
51
Units with 5-Tap Direct Drive Indoor Fan
51
Units with Belt Drive Indoor Fan
51
Units with Direct Drive Indoor Fan - Electromechanical Control
52
Tons High Efficiency)
52
Fan
52
Plus Units with the Constant CFM Direct Drive Indoor Fan
53
Vhr Relay Output
54
Variable Air Volume Applications
54
Vav)
54
Supply Duct Static Pressure Control
55
Traditional VAV Standalone Operation
55
Supply Air Temperature Reset
55
Return Air Smoke Detector
55
Economizer Start-Up
56
Compressor Start-Up
57
Dehumidification Option
57
Gas Heat Units
57
Final System Setup
57
Maintenance
59
Fan Belt Adjustment - Belt Drive Units
59
Monthly Maintenance
60
Filters
60
Return Air Smoke Detector Maintenance
60
Condensate Overflow Switch
60
Cooling Season
60
Heating Season
60
Coil Cleaning
61
Annual Maintenance
62
Troubleshooting
63
Reliatel™ Control
63
System Status Checkout Procedure
63
Method 1
63
Resetting Cooling and Ignition Lockouts
65
Zone Temperature Sensor (ZTS) Service Indi
65
Cator
65
Clogged Filter Switch
65
Fan Failure Switch
65
Condensate Overflow Switch
65
Zone Temperature Sensor (ZTS) Tests
65
Test 1 - Zone Temperature Thermistor (ZTEMP)
65
Test 2 - Cooling Set Point (CSP) and Heating Set Point (HSP)
65
Test 3 - System Mode and Fan Selection
65
Test 4 - LED Indicator Test
66
Cool & Service)
66
Relative Humidity Sensor Test
66
Programmable & Digital Zone Sensor Test
66
Reliatel™ Refrigeration Module (RTRM) Default Chart
66
Unit Operation Without a Zone Sensor
66
Unit Economizer Control (ECA) Troubleshoot
67
Ing
67
Reliatel™ Control
67
Electromechanical Control
67
Unit Economizer Control (ECA) Test Proce
69
Dures
69
Electromechanical Control
69
Troubleshooting Procedures for Direct Drive
69
Plenum Fan
69
Test Procedures
69
Unit Wiring Diagrams Numbers
70
Limited Warranty
73
Combination Gas Electric Air Conditioner
73
YCD, YCH, YSC and YHC (Parts Only)
73
Models Less than 20 Tons for Commercial Use
73
Ingersoll-Rand YHC072E Installation, Operation And Maintenance Manual (72 pages)
Packaged Rooftop Air Conditioners
Brand:
Ingersoll-Rand
| Category:
Air Conditioner
| Size: 10 MB
Table of Contents
Introduction
2
Warnings, Cautions, and Notices
2
Important Environmental Concerns
2
Important Responsible Refrigerant Practices
2
Copyright
3
Table of Contents
4
Model Number Description
6
Model Number Notes
7
Model Number Description - 17 Plus
8
Model Number Notes
9
General Information
10
Unit Inspection
10
Storage
10
Unit Nameplate
10
Compressor Nameplate
10
Microchannel Condenser Barcode ID
10
Unit Description
10
Economizer Control Actuator (Optional)
10
System Input Devices & Functions
11
Low Pressure Control
12
High Pressure Control
12
Power Exhaust Control (Optional)
12
Lead/Lag Control (Dual Circuit Only)
12
Evaporator Frost Control
13
Discharge Line Temp Switch (DLTS)
14
Smoke Detector Sensor (Optional)
14
Phase Monitor
14
Single Zone Variable Air Volume / Displacement Ventilation (Optional)
14
Human Interface - 5 Inch Color Touchscreen (Optional)
14
Unit Dimensions
15
Installation
22
Pre-Installation
22
Procedure
22
Foundation
24
Horizontal Units
24
Ductwork
25
Roof Curb
26
Downflow
26
Rigging
27
General Unit Requirements
27
Factory Installed Economizer
28
Temperature Limit Switch Usage for Gas
28
Heat Units
28
Horizontal Discharge Conversion
29
Units)
29
Instructions
29
Units)
30
TCO1 Instructions
31
Return Air Smoke Detector
31
Main Electrical Power Requirements
32
Through-The-Base Gas Installation
32
Requirements for Gas Heat
33
Condensate Drain Configuration
33
Filter Installation
34
Field Installed Power Wiring
34
Main Unit Power
35
Standard Wiring
35
Optional TBUE Wiring (Through-The-Base Electrical Option)
35
Field-Installed Control Wiring
36
Control Power Transformer
36
Controls Using 24 VAC
36
Controls Using DC Analog Input/Outputs (Standard Low Voltage Multi Conductor Wire)
36
DC Conductors
37
Space Temperature Averaging
41
Pre-Start
44
Voltage Imbalance
44
Electrical Phasing (Three Phase Motors)
44
Compressor Crankcase Heaters (Optional)
45
Reliatel™ Controls
45
Test Modes
46
Reliatel™ Controls
46
Electromechanical Controls Test Procedure
47
Unit Start-Up
48
Verifying Proper Air Flow
48
Units with 5-Tap Direct Drive Indoor Fan
48
Units with Belt Drive Indoor Fan
48
Units with Direct Drive Indoor Fan - Electromechanical Control
49
Reliatel™ Units with Direct Drive Indoor Fan (7½, 8½, 10 Tons High Efficiency)
49
Fan
49
Plus Units with the Constant CFM Direct Drive Indoor Fan
50
Variable Air Volume Applications
51
Vav)
51
Supply Duct Static Pressure Control
52
Traditional VAV Standalone Operation
52
Supply Air Temperature Reset
52
Return Air Smoke Detector
53
Economizer Start-Up
53
Compressor Start-Up
54
Dehumidification Option
54
Gas Heat Units
54
Final System Setup
55
Maintenance
56
Fan Belt Adjustment - Belt Drive Units
56
Monthly Maintenance
57
Filters
57
Return Air Smoke Detector Maintenance
57
Condensate Overflow Switch
57
Cooling Season
57
Heating Season
57
Coil Cleaning
58
Annual Maintenance
59
Troubleshooting
60
Reliatel™ Control
60
System Status Checkout Procedure
60
Method 1
60
Resetting Cooling and Ignition Lockouts
62
Zone Temperature Sensor (ZTS) Service Indi
62
Cator
62
Clogged Filter Switch
62
Fan Failure Switch
62
Condensate Overflow Switch
62
Zone Temperature Sensor (ZTS) Tests
62
Test 1 - Zone Temperature Thermistor (ZTEMP)
62
Test 2 - Cooling Set Point (CSP) and Heating Set Point (HSP)
62
Test 3 - System Mode and Fan Selection
62
Test 4 - LED Indicator Test
63
Cool & Service)
63
Relative Humidity Sensor Test
63
Programmable & Digital Zone Sensor Test
63
Reliatel™ Refrigeration Module (RTRM) Default Chart
63
Unit Operation Without a Zone Sensor
63
Unit Economizer Control (ECA) Troubleshoot
64
Ing
64
Reliatel™ Control
64
Electromechanical Control
64
Unit Economizer Control (ECA) Test Proce
66
Dures
66
Electromechanical Control
66
Troubleshooting Procedures for Direct Drive
66
Plenum Fan
66
Unit Wiring Diagrams Numbers
67
Limited Warranty
69
Combination Gas Electric Air Conditioner
69
YCC, YCD, YCH, YCP , YSC and YHC (Parts Only)
69
Models Less than 20 Tons for Residential Use
69
Ycz, Ycy, Ycx, Ycc, Ycd, Ych, Ycp, Yhc
69
And YSC (Parts Only)
69
Models Less than 20 Tons for Commercial Use
69
Advertisement
Advertisement
Related Products
Ingersoll-Rand YHC036E
Ingersoll-Rand YHC037E
Ingersoll-Rand YHC048F
Ingersoll-Rand YHC060F
Ingersoll-Rand YHC072F
Ingersoll-Rand YHC102F
Ingersoll-Rand YHC067E
Ingersoll-Rand YHC120F
Ingersoll-Rand YH*150
Ingersoll-Rand YH*300
Ingersoll-Rand Categories
Water Pump
Power Tool
Air Compressor
Impact Driver
Drill
More Ingersoll-Rand Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL