Sign In
Upload
Manuals
Brands
Infortrend Manuals
Measuring Instruments
EonStor DS S12S-J1002-R
Infortrend EonStor DS S12S-J1002-R Manuals
Manuals and User Guides for Infortrend EonStor DS S12S-J1002-R. We have
2
Infortrend EonStor DS S12S-J1002-R manuals available for free PDF download: Hardware Manual, Installation And Hardware Reference Manual
Infortrend EonStor DS S12S-J1002-R Hardware Manual (165 pages)
Brand:
Infortrend
| Category:
Measuring Instruments
| Size: 6 MB
Table of Contents
Copyright Notice
2
Safety Precautions
3
Table of Contents
6
About this Manual
9
1 Introduction
10
Product Overview
10
Model Naming Conventions
10
Model Variations
11
Major Components
13
S12 Vs S16 Vs S24 Series Rear Panel
14
Chassis
17
Front Panel
17
Rear Panel
18
Internal Backplane
21
Front Panel Components
22
LCD/LED Panel
22
Chassis Ear
24
Drive Tray
24
Rear Panel Components
26
Controller Module of RAID Models
26
Controller Module of JBOD Models
28
Host Port of RAID Models
29
CBM (Cache Backup Module) for RAID Models
34
S12X-Gxxxx Models PSU (Power Supply Unit)
37
S12X-Rxxxx Models and S16 RAID Series PSU (Power Supply Unit)
38
S24 RAID Series PSU
38
S12 and S16 RAID Series Cooling Module
39
S24 RAID Series Cooling Module
40
System Monitoring Features
41
Expansion Enclosure Support
41
I 2 C Bus
42
Firmware (FW) and Sanwatch
42
Audible Alarms
42
Hot-Swapping
43
2 Hardware Installation
44
Installation Prerequisites
44
Installation Procedures Overview
45
Unpacking the Subsystem
46
Box Contents
46
Preinstalled Components
46
Components to be Installed
47
Hard Drive Installation
47
Hard Drive Installation Prerequisites
47
Placing Hard Drive into Drive Tray
50
Inserting Hard Drive into Drive Tray
51
CBM Installation for RAID Models
52
Warnings and Precautions
52
Removing the RAID Controller
53
Installing the BBU
53
Installing the FBM
54
Inserting the RAID Controller
55
3 System Connection
56
General Considerations on Making Connections
56
Host-Side Topologies
57
Host-Side Parameters
57
Maximum Concurrent Host LUN Connection ("Nexus" in SCSI)
58
Maximum Queued I/O Count
59
Fibre-Host RAID Connections
59
Fibre-Host Components
60
Fibre-Host Topologies
61
Fibre Cabling
62
Simple End-To-End Connection
64
DAS (Direct-Attached) Connection
65
Switched Fabric Connection (Dual-Controller)
66
Switched Fabric Connection (Single-Controller)
68
SAS-Host RAID Connections
70
Sxxs-R/G2240-4 Controllers in das (Direct-Attached Storage) Configuration
71
DAS (Direct-Attached Storage) Connection with Redundant Host Path
74
DAS (Direct-Attached Storage) Connection to Two Servers
76
Iscsi-Host RAID Connections
77
Network & Host Connection Topologies
77
High Availability IP SAN with Redundant RAID Controller
79
Single-Controller with Fault-Tolerant Path
81
High Availability IP SAN (Remote Replication Enabled)
82
High Availability IP SAN with Port Trunk (Remote Replication Enabled)
84
Single-Controller with Trunk
86
Hybrid Host Connections
87
Single Hybrid Unit Connected to Fc/Iscsi Hosts
87
Utilizing Hybrid Iscsi Ports for Data Replication
88
JBOD Connections
89
Expansion Links
90
SAS Expansion Configuration
92
Configuration Rules
94
Management Console Connections
96
Power Connections
97
Checklist
97
Connecting Power Cords
98
Power on Procedure
100
Power on Status Check
100
LCD Screen
102
Power off Procedure
103
4 System Monitoring
104
Monitoring Features
104
Front Panel
106
LCD Keypad for RAID Models
106
LED Panel for JBOD Models
109
Drive Tray LED
111
Controller LED
112
Controller LED for RAID Models
112
Controller LED for JBOD Models
114
Restore Default LED for RAID Models
115
Ethernet Management Port LED for RAID Models
115
Fibre-Host Port LED for FC RAID Models
116
SAS-Host Port LED for SAS RAID Models
117
Iscsi-Host Port LED for Iscsi RAID Models
118
Psu Led
119
S12X-Rxxx Models and S16 RAID Power Supply Unit LED
119
S12X-Gxxxx Models and S24 RAID Power Supply LED
120
S12X-Rxxxx Models and S16 RAID System Cooling Module LED
121
S12X-Gxxxx Models RAID System Cooling Module LED
121
S24 RAID System Cooling Module LED
122
Alarms and I2C Bus
122
Audible Alarms
122
Restoring Default System Settings
123
Restoring Default Settings for Dual-Controller Models
123
Restoring Default Settings for Single-Controller Models
125
5 System Maintenance
126
Replacing the Controller Module(S): Single / Dual / Simultaneous Upgrade
127
Replacing the Memory Module for RAID Models
129
Replacing the CBM for RAID Models
130
BBU Fault Conditions and Precautions
131
Replacing the BBU
131
Replacing the FBM
132
Replacing the Power Supply Module
133
Detecting a Failed PSU
133
Replacing the PSU on S12X-Rxxxx Models and S16 RAID Systems
134
Replacing the PSU on S12X-Gxxxx Models
136
Replacing the PSU on S24 RAID System
138
Replacing a Cooling Module
141
For S12X-Rxxxx Models and S16 Series
141
For S12X-Gxxxx Models
142
For S24 Series
143
Replacing a Hard Disk Drive
144
Replacing the Enclosure
147
Differential Diagnosis to Determine Backplane Failure
147
Enclosure Replacement Must Knows
148
Enclosure Replacement Procedure
148
6 Appendix
151
Technical Specifications
151
Host/Drive Interface
151
RAID Configurations for RAID Models
152
Fault Tolerance for RAID Models
153
Power Supply
153
Dimensions
154
Environment
155
Pinouts
155
4Gb/S and 8Gb/S FC Port Pinouts for Fibre-Host RAID Models
156
SAS Host Port Pinouts for SAS-Host RAID Models
157
Gbe Ethernet Port Pinouts for Iscsi-Host RAID Models
157
Serial Port & Cable for RAID Models
158
Ethernet Management Port Pinouts for RAID Models
159
SAS Expansion Port Pinouts
159
STP Ethernet Cable (Optional Accessory: Fibre-Host RAID Models)
160
Certifications
161
Summary
161
Declarations
162
Contact Information
164
Customer Support
164
Sales Office
165
Advertisement
Infortrend EonStor DS S12S-J1002-R Installation And Hardware Reference Manual (88 pages)
Brand:
Infortrend
| Category:
Storage
| Size: 4 MB
Table of Contents
Disclaimer
3
Trademarks
3
Warnings and Certifications
4
Table of Contents
7
Precautions and Instructions
10
Safety Precautions
10
About this Manual
11
ESD Precautions
11
Related Documentation
11
Revision History
11
Who Should Read this Manual
11
Conventions
12
Lists
12
Naming
12
Software and Firmware Updates
13
Chapter 1 Introduction
15
Product Overview
15
Product Introduction
15
Model Variations
16
Chassis Overview
16
Front Panel Overview
17
Rear Panel Overview
17
Internal Backplane
18
Physical Dimensions
18
Major Subsystem Components
19
LED Panel
19
Chassis Ears
20
Drive Tray
21
The Expander Controller
23
Expansion Enclosure Support
23
Controller Module Interfaces
24
Psus
25
Cooling Modules
26
Enclosure Monitoring
27
I 2 C Bus
27
LED Indicators
27
Audible Alarms
28
Hot-Swappable Components
28
Hot-Swap Capability
28
Components
28
Chapter 2 Hardware Installation
31
Introduction
31
Installation Prerequisites
31
Safety Precautions
33
Precautions and Instructions
33
Static-Free Installation
35
Preparation
35
General Installation Procedure
36
Installation Procedure Flowchart
36
Unpacking the Subsystem
37
Preinstalled Components
38
Modules to be Installed
38
Rackmounting
38
Hard Drive Installation
38
Hard Drive Installation Prerequisites
38
Drive Installation
39
Drive Tray Installation
41
Chapter 3 Subsystem Connection
43
Host Connection Prerequisites
43
The Host Link Cables
43
Max. Number of Expansion Enclosures
45
Topology and Configuration Considerations
45
Basic Configuration Rules
45
Sample Topology
47
SAS Expansion Configuration
47
Physical Connections
49
Power Cord Connection
49
Chapter 4 System Operation and Monitoring
53
Power on
53
Check List
53
Power on Procedure
53
Power on Status Check
54
Power off Procedure
55
System Monitoring Overview
56
Status-Indicating Leds
58
Brief Overview of the Leds
58
LED Panel Leds
58
Drive Tray Leds
59
Controller Module Leds
60
4.4.3.1 Controller Status Leds
60
4.4.3.2 SAS Port Leds
61
PSU Leds
61
Cooling Module Leds
61
Audible Alarm
62
Failed Devices
62
I 2 C Monitoring
63
Chapter 5 System Maintenance
65
Overview
65
About Subsystem Maintenance
65
General Notes on Component Replacement
65
Replacing Controller Module Components
66
Considerations
67
Removing the Controller Module
67
Replacing the Controller Module
68
Replacing a Faulty Psu
70
PSU Overview
70
Replacing the PSU
70
Cooling Module Maintenance
73
Notes on Cooling Module Maintenance
73
Replacing a Cooling Module
74
Replacing a Hard Drive
76
Hard Drive Maintenance Overview
76
Appendix A Specifications
81
Technical Specifications
81
Environmental Specifications
81
Power Requirements
81
Vibration
82
Certifications
82
Warning Alarms (Via a Managing RAID Subsystem
82
Functional Specifications
82
Configuration Specifications
82
Drive Tray Specifications
83
Power Supply Specifications
83
Cooling Module Specifications
83
Appendix B Spare Parts and Accessories
85
Spare Parts
85
Accessories
85
Sas Connector Pinouts
87
Power Connectors
88
Advertisement
Related Products
Infortrend EonStor DS S12S-J1000-R
Infortrend EonStor DS S12S-J1000-G
Infortrend EonStor DS S12S-J2000-R
Infortrend EonStor DS S12S-G2240
Infortrend EonStor DS S12S-G2240-4
Infortrend EonStor DS S12S-R2240-4
Infortrend EonStor DS S12S-R2240
Infortrend EonStor DS S12E-G1140
Infortrend EonStor DS S12E-G2140
Infortrend EonStor DS S12E-R1140-4
Infortrend Categories
Storage
Network Storage Server
Computer Hardware
Speaker System
Measuring Instruments
More Infortrend Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL