Hubbell HPS/RFL Cable Accessories manual available for free PDF download: Instruction Manual
Hubbell HPS/RFL Instruction Manual (345 pages)
Brand:
Hubbell
| Category:
Cables and connectors
| Size: 13 MB
Table of Contents
Table of Contents
3
Safety Instructions
16
Warnings and Safety Summary
16
Figure 1-1. Location of Protective Earth Stud
16
External Labels, Warning and Cautions
19
Figure 1-2. External Labels, Warnings and Cautions
19
System Description
20
Key Features for the HPS/RFL™ GARD Pro™ System
20
Figure 2-1. the HPS/RFL GARD Pro System
20
Supplied Drawings
21
User System Label
21
Figure 2-2. Supplied Drawings
21
Table 2-1 Example User System Label Description
21
Figure 2-3. Example User System Label
22
Table 2-2 Example User System Label Description
22
System Modules with Available Options
23
System Slot Location and Module Description
23
Table 2-3 HPS/RFL GARD Pro System Module with Available Options
23
Figure 2-4. Module Placement in the HPS/RFL GARD Pro System (3U)
24
Figure 2-5. Module Placement in the HPS/RFL GARD Pro System (6U)
25
Figure 2-6. Programmable Leds
26
Figure 2-7. Base Input/Output Unit Showing Plug-On Boards
27
Figure 2-8. Top and Front Views of Comms I/O Base Module
28
Figure 2-9. GPS Antenna
30
Figure 2-10. Location of Synchronous Multi-Protocol Interface
31
Figure 2-11. HPS/RFL GARD Pro Display Card and Digital Teleprotection Slot Locations
32
Front Panel Indicators/Connections
33
Figure 2-12. HPS/RFL GARD Pro System Front Panel, Indicators/Connections
33
Graphical User Interface (GUI)
34
Figure 2-13. Graphical User Interface
34
Controller Redundancy
35
Table 2-4. Web Page, Controller Card, Status Color Codes
37
Figure 2-14. Chassis Configuration Status Web Page for 6U Chassis with Redundancy
38
Figure 2-15. Chassis Configuration Status Web Page for 6U Chassis with Unhealthy Inactive Controller
38
TSD (Touch Screen Display)
39
Figure 2-16. Touch Screen Display in 3U Chassis
39
Figure 2-17. System Information
40
Figure 2-18. Events Log (Soe's)
40
Figure 2-19. Push Button Menu
41
Figure 2-20. Test Menu
41
Figure 7-19. Status
41
Figure 2-21. Inventory Menu
42
Installation
43
Introduction
43
Unpacking
43
Mounting
44
Figure 3-1. Mounting Dimensions for the HPS/RFL GARD Pro System Chassis
45
Ventilation
46
System Module I/O Connections
47
Figure 3-2. System Module I/O Connections
47
Figure 3-3. RS-485 DNP3 Connection
49
Figure 3-4. Network Connections
50
Figure 3-5. 3U Chassis, System I/O Board Jumper Locations
52
Table 3-1. Jumpers Required on System I/O Board When GPS Module Is NOT INSTALLED
53
Figure 3-6. IRIG-B with GPS
54
Table 3-2. System I/O Jumper Settings with IRIG-B and GPS
54
Figure 3-7. RS-232 Pin-Outs
55
Figure 3-8. Removing System I/O Board (3U)
55
Figure 3-9. Jumper Location for IRIG-B through Rear RS-232 Connector (3U)
56
Figure 3-10. Removing System I/O Board (6U)
56
Figure 3-11. Jumper Location for IRIG-B through Rear RS-232 Connector (6U)
57
Rear I/O, Alarm Relay and Input Power Connections
58
Figure 3-12. Rear I/O Terminal Block Connections
58
Figure 3-13. Relay Connections/Power Supply I/O
59
Figure 3-14. Chassis Grounding Location
59
Discrete I/O Modules Connections/Pinouts
61
Figure 3-15. Top and Rear Views of Discrete I/O Base Module
62
Figure 3-16. Component Side of Input Unit (RF-500805)
63
Figure 3-17. Top and Rear Views of Discrete I/O Base Module (Continued)
64
Figure 3-18. Component Side of Relay Output Unit (RF-500815)
65
Digital Comms I/O Base Module and Digital Interfaces
66
Figure 3-19. Top and Rear View of Discrete I/O Base Module with Output Unit
66
Figure 3-20. Top and Front Views of Comms I/O Base Module
68
Figure 3-21. Panel Views of Various Types of Comms I/O Modules Available
69
Table 3-3. Digital Comms Interface Connections
70
Figure 3-25. Pin-Outs, RS-232
73
Current Limiter Option
74
Figure 3-26. Current Limiter Terminal Block Connection
74
System Boot-Up Sequence
75
Figure 3-27. Location of Leds on Controller Board
75
System Configuration
76
Connecting a Laptop and Setting IP Addresses
76
Figure 4-1. Front Ethernet Port
76
Configuring a PC Using DHCP and Static IP
77
Figure 4-2. Internet Access Icon
77
Figure 4-3. Local Area Connection
77
Figure 4-4. Properties
78
Figure 4-5. Internet Protocol Version
78
Figure 4-6. Obtain an IP Address Automatically
79
Figure 4-7. Use the Following IP Address
79
First Time Login to the HPS/RFL GARD Pro System Web Server
80
Figure 4-8. First Time Login
80
Figure 4-9. HPS/RFL GARD Pro System Dashboard
81
Table 4-1 Alarm States
81
Table 4-2 Setting Access Levels
82
Figure 4-10. Access Levels
83
Figure 4-11. Access Control
83
File Operations
84
Figure 4-12. Access Log
84
Figure 4-13. Send File to HPS/RFL GARD Pro System
85
Figure 4-14. Save File to PC
86
Web/Scp Server
88
Figure 4-15. Web/Scp Server
88
Table 4-3 Security Levels
89
Inventory and Software Information
92
Figure 4-16. Inventory and Version Control
92
Dynamic Menu Feature
93
Figure 4-17. Dynamic Menu Feature
93
Changing Settings - General Information
94
Input/Output Module
94
Figure 4-18. Settings, General Information
94
Figure 4-19. Removing Input/Output Module
95
Figure 4-20. Setting Jumpers on the Input Unit
95
Figure 4-21. Setting Switches on the Relay Output Unit
96
Figure 4-22. I/O Status
97
Figure 4-23. Configuring Inputs
98
Figure 4-24. Input Mapping
99
Figure 4-25. Inputs Advanced Configuration
100
Figure 4-26. Input Test
101
Figure 4-27. Output Configuration
102
Figure 4-28. Output Mapping
103
Figure 4-29. Output Advanced Configuration
104
Figure 4-30. Output Test
105
Front Panel LED Status and Configuration
107
Figure 4-31. LED Status
107
Figure 4-32. LED Configuration
108
Table 4-4 LED Priorities
108
System Alarms Status and Configuration
109
Figure 4-33. Alarm Status
109
Figure 4-34. Alarm Configuration
111
SOE Status and Configuration
112
Figure 4-35. Retrieving SOE Records
112
Figure 4-36. SOE Triggers
114
Figure 4-37. SOE Record Details (Logic Bits)
115
Figure 4-38. SOE Record Details (Logic Table)
116
Figure 4-39. SOE Counters
117
Logic Configuration
118
Figure 4-40. SOE Configuration
118
Figure 4-41. Logic Options
119
Figure 4-42. Logic Configuration, Timers
120
System Settings
121
Figure 4-43. System Configuration, Ethernet Labels
121
Figure 4-44. System Configuration, Clock
122
Advanced Settings
123
Figure 4-45. Advanced Settings, Logic Bits
123
Figure 4-46. Advanced Settings, HMI Bits
124
Figure 4-47. Navigate to Touch Screen Display Settings
125
Figure 4-48. TSD Wake-Up Settings
126
Figure 4-49. TSD Push Button Interface Configuration
127
Figure 4-50. TSD Push Button Interface
128
Table 4-5. TSD Push Button Interface Fields
128
Figure 4-51. TSD Blank Button
129
Figure 4-52. Service Channels
130
Dnp3
131
Figure 4-53. DNP Connections
131
Table 4-6. HPS/RFL GARD Pro System List of DNP3 Data Points
132
Figure 4-54. DNP Configuration
135
Table 4-7. General DNP Configuration Fields
136
Figure 4-55. DNP Configuration - Binary Input
137
Table 4-8. DNP Type Configuration Field Descriptions
138
Figure 4-56. DNP Configuration - Type 10 - Binary Output
139
Figure 4-57. DNP Configuration - Type 20 - SOE Counters
140
Figure 4-58. DNP Configuration - Type 20 - PLC Counters
141
Figure 4-59. DNP Configuration - Type 30 - Analog Input
142
Figure 4-60. DNP Deadband
143
Figure 4-61. DNP Status - General
144
Table 4-9. DNP Status Fields
145
Figure 4-62. DNP Status - Point List
146
Table 4-10. Field Descriptions for DNP Status
146
Figure 4-63. DNP Status - Type 1 - Binary Input
147
Figure 4-64. DNP Status - Type 10 - Binary Output
147
Figure 4-65. DNP Status - Type 20 - SOE Counters
148
Figure 4-66. DNP Type 20 - PLC Counters
148
Figure 4-67. DNP Status - Type 30 - Analog Input
149
Figure 4-68. DNP - Status
149
Figure 4-69. DNP - Status TSD
150
Snmp
151
Figure 4-70. Configuration - System
152
Figure 4-71. System Management - Passwords
153
Figure 4-72. Configuration - SNMP
154
Table 4-11. SNMP Configuration Webpage Fields
154
Table 4-12. SNMP Trap MIB Contents
155
Power Line Carrier
156
Power Line Carrier Function
156
Table 5-1 2F Trip Transport Delay and Channel Spacing
157
Table 5-2 3F Trip Transport Delay and Channel Spacing
157
Figure 5-1. Minimum Channel Spacing (FSK)
158
Table 5-3 On/Off Block Transport Delay and Channel Spacing
160
Table 5-4. Compatibility Issues for PLC Module Software
160
Making Connections to the Rear Analog PLC Module
162
Figure 5-2. as Supplied Drawing
162
Carrier Level Indicator (CLI) Front Panel Meter
163
Figure 5-3. HPS/RFL GARD Pro System PLC Analog Module
163
Figure 5-4. CLI Meter, Front Panel Mounting on a 3U Chassis
163
Table 5-5 TB1 Terminal Assignments
163
PLC Module User Interface
164
Figure 5-5. FSK Status
164
Table 5-6 Transmitter State
165
Table 5-7 Receiver State
165
Figure 5-7. FSK Configuration, Advanced
169
Figure 5-8. FSK Configuration Function Buttons
170
Table 5-8 Recommended FSK Settings
171
Figure 5-9. FSK Test
174
Figure 5-10. On/Off Status
175
Figure 5-12. On/Off Configuration, Advanced
179
Table 5-9 Recommended On/Off Settings
180
Figure 5-13. On/Off Configuration, Checkback
182
Table 5-10 Recommended Checkback Settings, 2-Terminal Line Testing
183
Table 5-11 Recommended Checkback Settings, 3-Terminal Line Testing
184
Figure 5-14. On/Off Configuration, Hard Carrier
186
Table 5-12 Recommended Hard Carrier Settings, 2-Terminal Line Testing
187
Table 5-13 Recommended Hard Carrier Settings, 3-Terminal Line Testing
187
Figure 5-15. On/Off Test
188
Figure 5-16. Activate Confirmation Dialog
188
Figure 5-17. Receiver Operating Range and Dynamic Range
189
Power Line Carrier Commissioning
190
Figure 5-18. PLC Calibration
191
Table 5-14. PLC Calibration
192
Figure 5-19. PLC Rear Module Adjustments
193
Figure 5-20. PLC Verifying Jumpers J12 through J15
195
Figure 5-21. PLC Verifying Jumpers J16 through J20
196
Figure 5-22. PLC Verifying Jumpers J21 through J25
197
Figure 5-23. PLC Jumper Settings, Transmit Carrier Frequency Range
198
Table 5-15. PLC Analog Module Assembly Part Numbers (RF-500935-X, New Board)
199
Table 5-16. TX Filter Jumper Settings (RF-500935-X, New Board)
199
Table 5-17. PLC Analog Module Assembly Part Numbers (RF-500930-X, Old Board)
200
Table 5-18. TX Filter Jumper Settings (RF-500930-X, Old Board)
200
Figure 5-24. PLC Analog Module, Carrier Level Indicator Modes - Jumpers
201
Figure 5-25. Location of Potentiometers on Digital PLC Module
202
Table 5-19. Carrier Level Indicator Loads
202
Figure 5-26. J6 Pin Numbers
203
Configuring 50 and 100W Applications with Optional 9508 RF Chassis
204
Figure 5-27. 9508 RF Chassis Mounted on the HPS/RFL GARD Pro System
204
Figure 5-28. Front View of the 9508 RF Chassis - Module Locations in 50W System
205
Table 5-20. Modules Included in the 9508 RF Chassis
205
Figure 5-29. 9508 RF Chassis Block Diagram
206
Figure 5-30. 9508 RF Chassis Power Amplifier
207
Figure 5-31. Additional 50W Module in 100W Systems
208
Figure 5-32. Location of 50W Power Amplifier Module
208
Figure 5-33. 50W Power Amp Circuit Board
209
Table 5-21 Function of the Jumpers, Connectors and Potentiometers on the Power Amp Circuit
209
Table 5-22 Function of the DIP Switches SW1 and SW2 on the Power Amp Board
210
Figure 5-34. Power Amplifier, Power Supply
211
Figure 5-35. Power Amplifier, Power Supply, Block Diagram
212
Table 5-23 Power Amp, Power Supplies
212
Figure 5-36. TX Filter, Top View
213
Figure 5-37. Location of Jumpers on the TX Filter, PC Board 107828-2
214
Table 5-24 TX Filter Setup Jumpers
215
Figure 5-38. Location of Jumpers on the TX Filter, PC Board 107828-1
216
Figure 5-39. Balance Board
217
Figure 5-40. Location of Jumpers on the Balance Board
218
Table 5-25 Setting Jumpers on the Balance Board
218
Figure 5-42. RFL9508 Line Board, Block Diagram
219
Figure 5-41. Line Board
221
Figure 5-43. Location of Jumpers on the Line Board
221
Table 5-26 Line Board, Setup Jumpers and Switch Settings
221
Figure 5-44. Location of Jumpers on the RX Filter Board
222
Figure 5-45. Location of Jumpers on the RX Filter Board, Showing Jumper Groupings
223
Figure 5-47. 9508 Mother Board, Rear View
225
Table 5-27 Motherboard Rear Panel Connector Assignments
225
Table 5-28 Motherboard, TB1 Terminal Assignments
226
Figure 5-48. Rear Panel Wiring of a Typical HPS/RFL GARD Pro System PLC with a 50W 9508
228
Figure 5-49. Rear Panel Wiring of a Typical HPS/RFL GARD Pro System PLC with a 100W 9508 RF Chassis
229
Optional Switched Battery Power Supply
230
Figure 5-50. Optional Power Supply I/O Module, Single On/Off Switch
230
Figure 5-51. Switched Battery Output, Functional Diagram
231
Installations with Two or more PLC Modules
232
Figure 5-52. Making Connections to a Second PLC Module
232
Figure 5-53. Setting Jumpers on Second PLC Analog Module
233
Table 5-29 TB1 Connections on Second PLC Module
233
Digital Teleprotection
234
Teleprotection Applications
234
Figure 6-1. Permissive Underreaching Transfer Trip
235
Figure 6-2. Permissive Overreaching Transfer Trip
235
Figure 6-3. Direct Transfer Trip
236
Figure 6-4. Directional Comparison Blocking
237
Digital Teleprotection Overview
238
Figure 6-5. Directional Comparison Unblocking
238
Digital Teleprotection Configuration
239
Figure 6-6. Digital Teleprotection Configuration - General Tab
240
Figure 6-7. Digital Teleprotection Timeslot Configuration Screen
242
Figure 6-8. Teleprotection Service Comms Bus Allocation
243
Figure 6-9. Teleprotection Service Comms Bus Configuration
243
Figure 6-10. Digital Comms Configuration Fields
248
Figure 6-11. Digital Teleprotection Configuration Example
249
Figure 6-12. TPS Configuration - Advanced Tab
250
Digital Teleprotection Status
251
Table 6-1 Digital Teleprotection Advanced Formula Table
251
Figure 6-13. TPS Status - Channel Tab
252
Figure 6-14. TPS Status - Advanced Tab
254
Digital Teleprotection Touch Screen Display Status
255
Figure 6-15. TSD - Digital Teleprotection
255
Figure 6-16. TSD - Digital Teleprotection Slot Selection
256
Figure 6-17. TSD - Digital Teleprotection, Channel Selection
257
Figure 6-18. TSD - Digital Teleprotection, Channel Selection, Function Table
258
Digital Communications Interfaces
260
Digital Communications Function
260
Configure Digital Comms Modules
261
Figure 7-1. Auxiliary Channel Terminal Pass Thru
261
Figure 7-2. Communications Interface Configuration
263
Figure 7-3. Configure Failed Error Message
264
Figure 7-4. T1/E1 Drop and Insert Example - Simplified
264
Figure 7-5. T1/E1Drop and Insert
264
Figure 7-6. Configuring T1 Digital Communications
265
Figure 7-7. Configuring E1 Digital Communications
266
Figure 7-8. Configuring C37.94 Digital Communications
267
Figure 7-9. Configuring G.703 Digital Communications
268
Figure 7-10. Configuring RS-449/X.21/V.35 Digital Communications
269
Figure 7-11. Configuring Direct Fiber Digital Communications
270
Figure 7-12. Configuring Async Digital Communications
271
Digital Communications Timeslot Configuration
272
Figure 7-13. Digital Comms Timeslot Configuration Screen
272
Figure 7-14. Comms Bus Allocation
273
Figure 7-15. Comms Bus Configuration
273
Figure 7-16. Digital Comms Configuration Fields
279
Service Channels
280
Figure 7-17. Configuring Service Channels
280
Figure 7-18. Service Channel Example
282
Table 7-1 Example Service Channel Settings
282
Digital Communications Status
284
Figure 7-20. Status Screen T1/E1 Digital Comms
285
Figure 7-21. Status Screen C37.94 Digital Comms
287
Figure 7-22. Status Screen G.703 Digital Comms
289
Figure 7-23. Status Screen RS-449 Digital Comms
291
Figure 7-24. Status Screen Direct Fiber Digital Comms
293
Figure 7-25. Status Screen Async Digital Comms
295
Figure 7-26. Status Screen Timeslot Bus Digital Comms
297
Digital Comms Test
298
Figure 7-27. Digital Comms Test - Normal
298
Figure 7-28. Digital Comms Test - Local Loopback
298
Figure 7-29. Digital Comms Test - Local Loopback Confirmation Message
299
Figure 7-30. Digital Comms Test - Remote Loopback
300
Figure 7-31. Digital Comms Test - Framer Loopback
301
Figure 7-32. Digital Comms Test - Payload Loopback
301
Figure 7-33. Digital Comms Test - C37.94 Loopback Tests
302
Troubleshooting
303
Introduction
303
System Alarms
303
Figure 8-1. Alarm Status in the Page Header
303
Figure 8-2. Alarm Status Page
304
Table 8-1 PLC Digital Module, Module Level Alarms
304
Connectivity Issues
305
Table 8-2. Digital Teleprotection/Communications Modules, Module Level Alarms
305
Figure 8-3. Connectivity Flow Chart
306
PLC Troubleshooting
307
Table 8-3 PLC Common PLC Troubleshooting Issues
307
Figure 8-4. PLC Digital Board
308
Table 8-4 Settings for the PLC Digital Board
309
Figure 8-5. PLC Analog Module Top View
311
Figure 8-6. PLC Analog Module Rear Panel View
312
Figure 8-7. PLC Power Amp Section
312
Table 8-5 Settings for the PLC Analog Module
313
Digital Teleprotection Troubleshooting
315
Figure 8-8. Digital Teleprotection Alarm Indicators
315
Digital Comms Troubleshooting
316
Figure 8-9. Digital Comms Alarm Indicators
316
Software Upgrade Utility
318
System Firmware Upgrade Overview
318
Figure 9-1. GARD Upgrade Utility
318
The HPS/RFL GARD Pro System Upgrade Tool Installation
319
The HPS/RFL GARD Pro System Firmware Upgrade Procedure
322
Technical Data/Specifications
328
System Specifications
328
Table 10-1 the HPS/RFL GARD Pro System Power Supply Specifications
330
Optional Modules
331
Table 10-2. Characteristics of Short Haul Module with Multimode Fiber Heads (C37.94) at 25ºC
333
Table 10-3. Characteristics of Short Haul Module with Single Mode Fiber Heads (C37.94) at
333
DNP3 Device Profile Document
334
Table 10-4. Characteristics of the Direct Fiber Module
334
Disposal
337
Index
338
Application Notes
344
Advertisement
Advertisement
Related Products
Hubbell H-MOSS
Hubbell H-MOSS ATP1277I
Hubbell HX Series
Hubbell HBLGW0400ELUS1
Hubbell HBLGW0400MLUS1
Hubbell SPIKESHIELD HBL4P120B
Hubbell Spikeshield HBL3P160DB
Hubbell Spikeshield HBL3P320B
Hubbell Spikeshield HBL4P160B
Hubbell Spikeshield HBL4P160DB
Hubbell Categories
Controller
Switch
Lighting Equipment
Accessories
Enclosure
More Hubbell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL