Table of Contents
Table of Contents
4
1 Using this Manual
6
Target Group of this Document
6
Means of Representation
6
Icons and Signal Words
6
Graphic Symbols / Pictograms on the Battery System
7
Notation of Nominal Data
8
Abbreviations and Glossary of Terms
8
2 Safety Instructions
9
Potential Hazards
9
Explosive Gas Mixture
9
Electrical Voltage
10
Electrolyte
10
Toxic Substances
11
Fire
12
Improper Transport
12
Notes on Disassembly
13
Personal Protective Equipment
13
Markings on the Product
13
3 Use of the Product
14
Intended Use
14
Unintended Use
14
4 Directives, Legislation and Standards
15
5 Function and Structure
16
Battery
16
Rail.power Blocks/Cells
16
Charging Methods for Rail. Power Blocks/Cells
17
Single-Stage Charging with Constant Current, Constant Voltage (IU)
17
Two-Stage Charging with Constant Current, Constant Voltage (IU0U)
18
Technical Data
19
Overview Rail.power Blocks/Cells
19
Technical Details
19
Battery Charging Characteristics
20
One Stage, Temperature Compensated Charging (IU-Charging)
20
Two Stage, Temperature Compensated Charging (IU0U-Charging)
21
6 Notes for Transport
23
Transportation of Undamaged Batteries
23
Transportation of Damaged Batteries
24
7 Notes on Storage
24
Storage with Permanent Float Charge
25
Storage with Regularly Recharge
25
Storage with Built-In Battery
26
8 Assembly / Commissioning
27
9 Maintenance
29
Preventive Maintenance
29
Visual Inspection of the Battery
30
Measurement of the Charging Voltage
31
Cleaning the Battery
32
Measuring the Insulation Resistance
33
Measuring the Open-Circuit Voltage on each Battery Block/Cell
35
Corrective Maintenance
36
Exchange of Rail.power Blocks/Cells
36
Exchanging a Cell Connector
38
Exchange of the Temperature Sensor
39
10 Troubleshooting
40
Insufficient Capacity
40
Insufficient Insulation Resistance
40
No Battery Voltage Can be Measured
41
Malfunction of the Temperature Sensor
41
11 Disassembly
42
12 Disposal
43
13 Appendix
44
Additional Tools
44
Maintenance Protocol
45
Half Yearly Maintenance Interval
45
Maintenance - Visual Inspection of the Battery
45
Yearly Maintenance Interval
46
Maintenance - Measurement of the Charging Voltage
46
Maintenance - Cleaning the Battery
46
Maintenance - Measuring the Insulation Resistance
46
Maintenance Interval 4 Years
47
Maintenance - Measuring the Open-Circuit Voltage on each Battery Block / Cell
47
Advertisement
Advertisement
Related Products
Hoppecke power.com SA
Hoppecke power.com H.C
Hoppecke power.com XC
Hoppecke Categories
Battery Pack
Camera Accessories
Battery Charger
Water System
Inverter
More Hoppecke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL