Sign In
Upload
Manuals
Brands
Hioki Manuals
Portable Generator
U8793
Hioki U8793 Manuals
Manuals and User Guides for Hioki U8793. We have
5
Hioki U8793 manuals available for free PDF download: Instruction Manual
Hioki U8793 Instruction Manual (144 pages)
Arbitrary Waveform Generator Unit, Waveform Generator Unit, Pulse Generator Unit
Brand:
Hioki
| Category:
Pulse Generator
| Size: 5 MB
Table of Contents
Table of Contents
3
Introduction
7
Verifying Package Contents
8
Safety Information
8
Operating Precautions
11
1 Overview
13
Features
13
3 Signal Generation
13
Part Names and Functions
14
Inspecting the Unit before Use
15
Connecting the Unit
17
Installing the Unit in and Removing the Unit from a Memory Hicorder
17
X84; Installing the Unit
17
X84; Removing the Unit
17
Connecting Cables to the Output Terminals
18
Output Terminals
19
Connecting Wires to the External Control Terminals (U8793)
20
Settings Screen (Generator Screen)
21
X84; Method for Copying and Pasting Channel Settings
22
4 FG Waveform Settings (U8793, MR8790)
23
X84; Method for Setting Values
24
Setting the Waveform Type
26
Setting the Frequency
27
Setting the Amplitude
28
Setting the Offset
29
Setting the Duty (Pulse Wave Output Only)
30
Setting the Phase
31
Setting the Output to on or off
32
Setting Behavior When Output Is off
33
5 Setting Pulse and Pattern Output (MR8791)
35
Setting the Mode
35
Setting the Pulse Mode
36
X84; Setting the Frequency
36
X84; Setting the Duty
37
X84; Setting the Output Type
38
X84; Setting Output
39
Setting the Pattern Mode
40
X84; Setting the Output Type
40
X84; Setting the Pattern to Use
41
X84; Method for Registering a Pattern
42
X84; Setting the Clock Frequency
44
X84; Setting Output
45
6 Sweep Setting (U8793)
47
Selecting the Sweep Type
47
Setting the Start Value
48
Setting the End Value
49
Setting the Sweep Time
50
Arbitrary Waveform Settings (U8793)
51
Setting the Waveform Type
51
Registering a Waveform
52
X84; Registering Data Measured with a Memory Hicorder
53
X84; Registering Data Created with the SF8000 Waveform Maker
55
Setting the Clock Frequency
57
Setting Amplitude Adjustment
58
Setting the Offset
59
Setting the Delay
60
Setting the Number of Loops (When Sweep Is Disabled)
61
Setting the Filter
62
Setting the Output to on or off
63
Setting Behavior When Output Is off
64
8 Program Settings (U8793)
65
Switching to the Program Settings Screen
65
Editing the Program
66
X84; Opening the Edit Screen
66
X84; Configuring each Step
67
X84; Ending Program Editing
69
Setting the Overall Number of Loops
71
Setting the Filter
72
Saving the Edited Program
73
Checking Program Progress
74
9 Outputting Signals
75
Setting the Control Method
75
Setting Output When Measurement Completes
76
Controlling Signal Output
77
10 Configuring Settings on the Waveform Screen
79
Setting Output Waveform Parameters
79
X84; to Display the Waveform and Output Parameter Settings in Separate Windows
80
Waveform Type and Output Status Display
82
11 Self-Test Function
83
Monitoring Output Values with Test Output
83
12 External Output Terminal (U8793)
87
External Input
88
External Output
89
13 Waveform Maker
91
Overview of the SF8000 Waveform Maker
91
X84; Operating Environment
91
X84; Functional Specifications
91
Installing the SF8000 Application
93
Launching and Exiting the SF8000 Application
95
X84; Launching the Application
95
X84; Exiting the Application
96
Uninstalling the SF8000 Application
97
SF8000 Screen
98
X84; Setting the Display Format
99
X84; Setting the Time Axis Range
100
X84; Input Mode Screens
100
Arbitrary Waveform Input Mode
102
X84; Basic Instructions
102
X84; Editing Mode
103
X84; Waveform Creation
104
X84; Properties
106
X84; Calculations Using Previously Input Waveforms
107
Function Input Mode
108
X84; Basic Instructions
108
X84; Example of Program Creation
108
X84; Expressions and Operations
109
X84; Control Words
110
X84; Functions
112
X84; Usable Characters
115
Step Input Mode
116
X84; Basic Instructions
116
X84; Example of Waveform Creation
116
X84; Start and End Point Settings
116
X84; Waveform Type and Settings
116
X84; Editing Steps
117
X84; Reordering the Display
117
Interpolation Input Mode
118
X84; Basic Instructions
118
X84; Editing Mode
120
X84; Dot Data List
120
X84; Interpolation Method
122
Pulse Pattern Mode
123
X84; Basic Instructions
123
X84; Example of Waveform Creation
124
Transferring Data
125
Saving and Loading Data
126
X84; Saving and Loading All Data
126
X84; Saving and Loading Data for an Individual Input Mode (Import, Export)
127
14 Specifications
129
U8793 Arbitrary Waveform Generator Unit
129
X84; General Specifications
129
X84; Output Specifications
129
X84; Sweep Function Specifications
131
X84; Program Functional Specifications
131
X84; Other Specifications
131
MR8790 Waveform Generator Unit
132
X84; General Specifications
132
X84; Voltage Output Specifications
133
MR8791 Pulse Generator Unit
134
X84; General Specifications
134
X84; Pulse Output Specifications
135
X84; Pattern Output Specifications
135
X84; Output Connector Specifications
135
15 Maintenance and Service
137
Cleaning the Unit
137
Troubleshooting
138
Error Messages
139
Index
141
Advertisement
Hioki U8793 Instruction Manual (134 pages)
ARBITRARY WAVEFORM GENERATOR UNIT
Brand:
Hioki
| Category:
Inverter
| Size: 3 MB
Table of Contents
Table of Contents
2
Introduction
5
Verifying Package Contents
6
Safety Information
6
Operating Precautions
9
1 Overview
11
Features
11
Part Names and Functions
12
Inspecting the Unit before Use
13
2 Connecting the Unit
14
Installing the Unit in and Removing the Unit from a Memory Hicorder
14
Installing the Unit
14
Removing the Unit
14
Connecting Cables to the Output Terminals
15
Output Terminals
16
Connecting Wires to the External Control Terminals (U8793)
17
3 Signal Generation Settings Screen (Generator Screen)
18
Method for Copying and Pasting Channel Settings
19
4 FG Waveform Settings (U8793, MR8790)
20
Method for Setting Values
21
Setting the Waveform Type
23
Setting the Frequency
24
Setting the Amplitude
25
Setting the Offset
26
Setting the Duty (Pulse Wave Output Only)
27
Setting the Phase
28
Setting the Output to on or off
29
Setting Behavior When Output Is off
30
5 Setting Pulse and Pattern Output (MR8791)
31
Setting the Mode
31
Setting the Pulse Mode
32
Setting the Frequency
32
Setting the Duty
33
Setting the Output Type
34
Setting Output
35
Setting the Pattern Mode
36
Setting the Output Type
36
Setting the Pattern to Use
37
Method for Registering a Pattern
38
Setting the Clock Frequency
40
Setting Output
41
6 Sweep Setting (U8793)
42
Selecting the Sweep Type
42
Setting the Start Value
43
Setting the End Value
44
Setting the Sweep Time
45
7 Arbitrary Waveform Settings (U8793)
46
Setting the Waveform Type
46
Registering a Waveform
47
Registering Data Measured with a Memory Hicorder
48
Registering Data Created with the SF8000 Waveform Maker
50
Setting the Clock Frequency
52
Setting Amplitude Adjustment
53
Setting the Offset
54
Setting the Delay
55
Setting the Number of Loops (When Sweep Is Disabled)
56
Setting the Filter
57
Setting the Output to on or off
58
Setting Behavior When Output Is off
59
8 Program Settings (U8793)
60
Switching to the Program Settings Screen
60
Editing the Program
61
Opening the Edit Screen
61
Ending Program Editing
64
Setting the Overall Number of Loops
66
Setting the Filter
67
Saving the Edited Program
68
Checking Program Progress
69
9 Outputting Signals
70
Setting the Control Method
70
Setting Output When Measurement Completes
71
Controlling Signal Output
72
10 &Rq¿Jxulqj6HwwlqjvRq
75
Setting Output Waveform Parameters
75
Waveform Type and Output Status Display
77
11 Self-Test Function
78
Monitoring Output Values with Test Output
78
12 External Output Terminal (U8793)
81
External Output
81
13 Waveform Maker
84
Overview of the SF8000 Waveform Maker
84
Operating Environment
84
Installing the SF8000 Application
86
Launching and Exiting the SF8000 Application
88
Launching the Application
88
Exiting the Application
89
Uninstalling the SF8000 Application
90
SF8000 Screen
91
Setting the Display Format
92
Setting the Time Axis Range
93
Input Mode Screens
93
Arbitrary Waveform Input Mode
95
Basic Instructions
95
Editing Mode
96
Waveform Creation
97
Properties
99
Calculations Using Previously Input Waveforms
100
Function Input Mode
101
Basic Instructions
101
Example of Program Creation
101
Expressions and Operations
102
Control Words
103
Functions
105
Usable Characters
108
Step Input Mode
109
Basic Instructions
109
Example of Waveform Creation
109
Start and End Point Settings
109
Waveform Type and Settings
109
Editing Steps
110
Reordering the Display
110
Interpolation Input Mode
111
Basic Instructions
111
Editing Mode
113
Dot Data List
113
Interpolation Method
115
Pulse Pattern Mode
116
Basic Instructions
116
Example of Waveform Creation
117
Transferring Data
118
Saving and Loading Data
119
Saving and Loading All Data
119
Saving and Loading Data for an Individual Input Mode (Import, Export)
120
U8793 Arbitrary Waveform Generator Unit
123
MR8790 Waveform Generator Unit
125
MR8791 Pulse Generator Unit
127
15 Maintenance and Service
130
Cleaning the Unit
130
Troubleshooting
131
Error Messages
132
Index
133
Hioki U8793 Instruction Manual (134 pages)
ARBITRARY WAVEFORM GENERATOR UNIT, WAVEFORM GENERATOR UNIT, PULSE GENERATOR UNIT
Brand:
Hioki
| Category:
Portable Generator
| Size: 5 MB
Table of Contents
Table of Contents
2
Introduction
5
Verifying Package Contents
6
Safety Information
6
Operating Precautions
9
1 Overview
11
Features
11
Part Names and Functions
12
Inspecting the Unit before Use
13
Connecting the Unit
14
Installing the Unit in and Removing the Unit from a Memory Hicorder
14
X84; Installing the Unit
14
Connecting Cables to the Output Terminals
15
Output Terminals
16
Connecting Wires to the External Control Terminals (U8793)
17
3 Signal Generation
18
Settings Screen (Generator Screen)
18
X84; Method for Copying and Pasting Channel Settings
19
4 FG Waveform Settings (U8793, MR8790)
20
X84; Method for Setting Values
21
Setting the Waveform Type
23
Setting the Frequency
24
Setting the Amplitude
25
Setting the Offset
26
Setting the Duty (Pulse Wave Output Only)
27
Setting the Phase
28
Setting the Output to on or off
29
Setting Behavior When Output Is off
30
5 Setting Pulse and Pattern Output (MR8791)
31
Setting the Mode
31
Setting the Pulse Mode
32
X84; Setting the Duty
33
X84; Setting the Output Type
34
Setting the Pattern Mode
36
X84; Setting the Pattern to Use
37
X84; Method for Registering a Pattern
38
X84; Setting the Clock Frequency
40
6 Sweep Setting (U8793)
42
Selecting the Sweep Type
42
Setting the Start Value
43
Setting the End Value
44
Setting the Sweep Time
45
Arbitrary Waveform Settings (U8793)
46
Setting the Waveform Type
46
Registering a Waveform
47
X84; Registering Data Measured with a Memory Hicorder
48
X84; Registering Data Created with the SF8000 Waveform Maker
50
Setting the Clock Frequency
52
Setting Amplitude Adjustment
53
Setting the Offset
54
Setting the Delay
55
Setting the Number of Loops (When Sweep Is Disabled)
56
Setting the Filter
57
Setting the Output to on or off
58
Setting Behavior When Output Is off
59
8 Program Settings (U8793)
60
Switching to the Program Settings Screen
60
Editing the Program
61
X84; Opening the Edit Screen
61
X84; Configuring each Step
62
X84; Ending Program Editing
64
Setting the Overall Number of Loops
66
Setting the Filter
67
Saving the Edited Program
68
Checking Program Progress
69
9 Outputting Signals
70
Setting the Control Method
70
Setting Output When Measurement Completes
71
Controlling Signal Output
72
10 Configuring Settings on the Waveform Screen
74
Setting Output Waveform Parameters
74
X84; to Display the Waveform and Output Parameter Settings in Separate Windows
75
Waveform Type and Output Status Display
77
11 Self-Test Function
78
Monitoring Output Values with Test Output
78
12 External Output Terminal (U8793)
81
External Input
82
External Output
83
13 Waveform Maker
84
Overview of the SF8000 Waveform Maker
84
X84; Operating Environment
84
X84; Functional Specifications
84
Installing the SF8000 Application
86
Launching and Exiting the SF8000 Application
88
X84; Launching the Application
88
X84; Exiting the Application
89
Uninstalling the SF8000 Application
90
SF8000 Screen
91
X84; Setting the Display Format
92
X84; Setting the Time Axis Range
93
X84; Input Mode Screens
93
Arbitrary Waveform Input Mode
95
X84; Basic Instructions
95
X84; Waveform Creation
97
X84; Calculations Using Previously Input Waveforms
100
Function Input Mode
101
X84; Example of Program Creation
101
X84; Expressions and Operations
102
X84; Usable Characters
108
Step Input Mode
109
X84; Example of Waveform Creation
109
X84; Start and End Point Settings
109
X84; Waveform Type and Settings
109
X84; Reordering the Display
110
Interpolation Input Mode
111
X84; Interpolation Method
115
Pulse Pattern Mode
116
Transferring Data
118
Saving and Loading Data
119
X84; Saving and Loading All Data
119
X84; Saving and Loading Data for an Individual Input Mode (Import, Export)
120
14 Specifications
122
U8793 Arbitrary Waveform Generator Unit
122
X84; General Specifications
122
X84; Output Specifications
122
X84; Sweep Function Specifications
124
X84; Program Functional Specifications
124
X84; Other Specifications
124
MR8790 Waveform Generator Unit
125
X84; Voltage Output Specifications
126
MR8791 Pulse Generator Unit
127
15 Maintenance and Service
130
Cleaning the Unit
130
Troubleshooting
131
Error Messages
132
Index
133
Advertisement
Hioki U8793 Instruction Manual (2 pages)
MODULES FOR MEMORY HiCORDERS
Brand:
Hioki
| Category:
Control Unit
| Size: 0 MB
Hioki U8793 Instruction Manual (2 pages)
FOR MEMORY HiCORDERS
Brand:
Hioki
| Category:
Control Unit
| Size: 2 MB
Advertisement
Related Products
Hioki 7075
Hioki 7075-01
Hioki MR8790
Hioki MR8791
Hioki SM7860 Series
Hioki SM7860-01
Hioki SM7860-02
Hioki SM7860-03
Hioki SM7860-04
Hioki SM7860-05
Hioki Categories
Measuring Instruments
Test Equipment
Data Loggers
Multimeter
Accessories
More Hioki Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL