Sign In
Upload
Manuals
Brands
Halstrup-Walcher Manuals
Measuring Instruments
PUC 28
Halstrup-Walcher PUC 28 Monitoring Device Manuals
Manuals and User Guides for Halstrup-Walcher PUC 28 Monitoring Device. We have
1
Halstrup-Walcher PUC 28 Monitoring Device manual available for free PDF download: Instruction Manual
Halstrup-Walcher PUC 28 Instruction Manual (51 pages)
Process monitoring device for clean rooms
Brand:
Halstrup-Walcher
| Category:
Measuring Instruments
| Size: 1.34 MB
Table of Contents
Table of Contents
2
1 Validity and Purpose of the Instruction Manual
4
2 Safety Precautions
5
Appropriate Use
5
Shipping, Assembly, Electrical Connections and Start-Up
5
Troubleshooting, Maintenance, Repairs, Disposal
5
Symbols
6
3 Device Description
7
General Functional Description
7
Cyclic Zero-Point Calibration
8
Display of Measured Values
8
Display and Controls
9
Manual Zero-Point Calibration
10
Re-Calibration
10
Connections
10
4 Assembly
12
5 Setting the Parameters
13
Abbreviations Used
14
Basic Settings [ SETTINGS ]
15
Language [ SETTINGS / LANGUAGE ]
15
Changing the Password [ SETTINGS / NEW PASSWD ]
15
Measurement Range of the Internal Pressure Sensor [ SETTINGS / MEAS. R. ]
15
External Sensors (IN1 and IN2) [ SETTINGS / CONF. EXTERN ]
16
Display [ SETTINGS / DISPLAY ]
16
Signal [ SETTINGS / SIGNAL ]
17
Acoustic Signalling Device [ SETTINGS / SOUND ]
17
Decimal Places Display [ SETTINGS / DECIMAL PL. ]
17
Delete Re-Calibration [ SETTINGS / UNDO TEACH ]
18
Reset the Device [ SETTINGS / RESET ]
18
Recall the Delivery State [ SETTINGS / DELIVERY ST. ]
18
Scaling and Limits [ VALUES ]
18
Scaling [ VALUES / SCALE ]
19
Limits [ VALUES / WARNING ]
19
Filter Setting [ FILTER ]
21
Relays [ RELAY ]
22
Switching Conditions and Relay Test [ RELAY / COND. TEST ]
22
Relay Activation and Deactivation Delays [ RELAY / TIME REL. ]
23
Alarm Acknowledgement [ RELAY / ACKNOWLEDGE ]
24
Re-Calibration [ TEACH ]
24
6 RS232 Interface
26
List of RS232 Commands
26
Commands for Configuration
26
Instruction Manual PUC
28
Commands for Reading the Measured Values and the Status Values
29
Other Commands
30
Error Codes
32
Assignment of the RS232 Connector
33
Interface Configuration
34
Configuration Software
34
7 Profibus DP Interface
38
Profibus DP Address
38
Terminating Resistors
38
Modules
39
Setting the Parameters of the PUC 28 as a Profibus Slave
41
Assignment of the Profibus Connector
42
8 Adjusting the PUC 28 [ TEACH ]
43
Adjusting the Internal Pressure Transmitter
43
Adjusting the Analogue Inputs and Outputs
44
9 Care Instructions for PUC 28
44
10 Technical Data
45
11 Troubleshooting
45
12 Dimension Drawing
46
13 Menu Tree
47
14 Ranges of Values and Default Settings
50
Advertisement
Advertisement
Related Products
halstrup-walcher PU
halstrup-walcher PI
halstrup-walcher PU10
Halstrup-Walcher PSW3**PL series
Halstrup-Walcher PSE3**IO series
Halstrup-Walcher PSW3**DN series
Halstrup-Walcher PSE3**DN series
halstrup-walcher PSD411-5V
halstrup-walcher PSE2DN Series
halstrup-walcher PSD424
Halstrup-Walcher Categories
Valve Positioners
Transducer
Measuring Instruments
Transmitter
Controller
More Halstrup-Walcher Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL