hager EU400 NA-protection Voltage Relay Manuals
Manuals and User Guides for hager EU400 NA-protection Voltage Relay. We have
1
hager EU400 NA-protection Voltage Relay manual available for free PDF download: Operating Manual
hager EU400 NA-protection Operating Manual (44 pages)
System-disconnection relay
Brand:
hager
| Category:
Relays
| Size: 2 MB
Table of Contents
Table of Contents
4
General Notes
6
Display and Controls
6
Default Settings and Firmware Version, VDE-AR-N 4105 + BDEW
8
Default Settings and Firmware Version, VDE-AR-N 4110 + 4120:2018-11
10
Default Settings and Firmware Version, TOR Erzeuger Typ A,B,C,D, VSE NA/EEA-NE7 CH 2020, G98(83/2)+G99(G59/3), Synergrid C10 / C11
12
Application and Brief Description
14
Summary of the Functions
14
Connection Diagrams
15
PV, 1X Section Switch (VDE-AR-N 4105:2018-11)
15
PV, 2X Section Switch (VDE-AR-N 4105:2011)
16
Multiple PV with Section Switch and with a Series-Switched Nc's as Feedback Contacts
17
Multiple PV with Section Switch and with a Parallel-Switched Closing Contacts as Feedback
18
PV, 1X Section Switch with Nc/Normally Closed Contacts (Medium Voltage VDE-AR-N 4110:2018-11 / High Voltage VDE-AR-N 4120:2018-11)
19
Using Integrated Switches of PV and Battery Inverters According to DIN en 62109 (VDE 0126-4)
20
Generator Operation, Suppression of the Feedback Contacts
21
Important Information
22
Assembly
22
Detailed Description
23
Description of the Connections
23
Functional Characteristics
24
Commissioning
25
Program Setup
25
Control Chart Pr 2
26
Control Chart Pr 1 and Pr 7
27
Description of the Parameters
28
Display Mode (Last Decimal Point Off)
29
Menu Mode (Last Decimal Point On)
29
Configuration Mode (Last Decimal Point Flashes)
29
Switching Conditions
30
Disengaging Ratio
30
Monitoring of Zero Voltage
30
Test Mode (Timekeeping Only Activated and Connected Feedback Contacts)
31
Alarm Counter
31
Cumulative Alarm Time (Display in Hours)
31
Alarm Memory
32
Standby Counter and Standby Time
32
Code Lock
32
Sealing
33
Simulation
33
Possible Indications in Display
34
Technical Data
35
Troubleshooting and Measures
38
Maintenance and Repair
39
Construction Form V6
39
Disposal
39
Adjustment Values Table VDE-AR-N 4105:2011, Low Voltage Pr 1+7
40
Adjustment Values Table BDEW June 2008, Acc 3.2.3.3-1, Medium Voltage Pr 3-6
40
Adjustment Values Table VDE-AR-N 4105:2018-11, Low Voltage 6. Table 2, Pr 2
41
Adjustment Values
41
Voltage) Higher Protection Pr 11+12
41
Adjustment Values VDE-AR-N 4110:2018-11, Medium Voltage Unit Protection Pr 13+14
42
Adjustment Values VSE: NA/EEA-NE-7 - CH 2020 A.2.2 IPE > 30 Kva und ≤ 250 Kva (5)
42
Adjustment Values VSE: NA/EEA-NE-7 - CH 2020 A.2.3 IPE > 250 Kva (1)
43
Advertisement
Advertisement
Related Products
hager EG071
hager EG010
hager EE610
hager EGN100AU
hager EGN200AU
hager EGN400AU
hager EGN100
hager EGN200
hager EGN400
hager EE600
hager Categories
Circuit breakers
Switch
Timer
Controller
Control Unit
More hager Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL