Sign In
Upload
Manuals
Brands
Haag-Streit Manuals
Medical Equipment
Eyestar 900
Haag-Streit Eyestar 900 Manuals
Manuals and User Guides for Haag-Streit Eyestar 900. We have
3
Haag-Streit Eyestar 900 manuals available for free PDF download: Instructions For Use Manual
Haag-Streit Eyestar 900 Instructions For Use Manual (26 pages)
Brand:
Haag-Streit
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
2
Comments on These Instructions for Use
4
Ambient Conditions
4
Shipment and Unpacking
4
Installation Warnings
4
Operation, Environment
5
Plausibility of the Measurements
6
IOL Calculation
7
Optical Radiation
8
Disinfection
8
Warranty and Product Liability
8
Reporting Obligation
8
Description of Symbols
8
Intended Purpose / Intended Use
9
Device Description
9
Intended Users
9
Medical Purpose
9
Indications
9
Part of the Body
9
Patient Population
9
Contraindications
9
Introduction
10
Eyestar 900 Components
10
Device State Indicator
11
Touch Screen
11
Device Assembly / Installation
11
Forehead Band and Chin Rest
11
Replacement of the Forehead Band
12
Replacement of the Chin Rest Tray
12
Operation
12
Commissioning
14
Switching on the Device
14
Switching off the Device
14
Technical Data
14
General Data
14
Power
14
Illumination Modalities
14
OCT Light Source
14
Imaging System Light Source
14
Primary Fixation Target
14
Lens Thickness (LT)
15
Axial Length (AL)
15
Keratometry (K)
15
White-To-White Distance (WTW)
15
Pupillometry (PD)
15
Topography
15
In Vivo Repeatability Standard Topography (7.5 MM Diameter)
15
Simulated Posterior Keratometry (Simpk), Standard Topography (7.5 MM Diameter)
16
In Vivo Repeatability Extended Topography (12 MM Diameter)
16
Simulated Anterior Keratometry (Simek), Extended Topography (12 MM Diameter)
16
Simulated Anterior Keratometry (Simk), Standard Topography (7.5 MM Diameter)
16
Simulated Posterior Keratometry (Simepk), Extended Topography (12 MM Diameter)
17
Normative Considerations
17
Crystalline Lens Tilt
17
Software / Help Menu / Error Messages
18
Maintenance
18
Cleaning and Disinfection
18
Device in General
18
Applied Parts
18
Tools
18
Cleaning and Disinfecting Details
19
Dust Cover
19
Accessories / Consumables / Spare Parts / Upgrade
19
Legal Regulations
19
Classification
19
Disposal
20
Observed Standards
20
Information and Manufacturer's Declaration Concerning Electromagnetic Compatibility (EMC)
20
General
20
Emitted Interference
21
Electromagnetic Immunity Environment Tested (Part 1)
22
Electromagnetic Immunity Environment Tested (Part 2)
23
Recommended Separation Distances between Portable and Mobile RF Communications Equipment and this Product
25
Advertisement
Haag-Streit Eyestar 900 Instructions For Use Manual (20 pages)
Biometer
Brand:
Haag-Streit
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Safety
4
Areas of Application of the Device
4
Patient Population
4
Ambient Conditions
4
Shipment and Unpacking
4
Installation Warnings
4
Operation, Environment
5
Plausibility of the Measurements
6
IOL Calculation
7
Optical Radiation
7
Disinfection
7
Warranty and Product Liability
7
Description of Symbols
7
2 Introduction
8
Basic Construction
8
Operating Principles
8
Eyestar 900 Components
8
Device State Indicator
9
Touch Screen
9
3 Appliance Assembly / Installation
9
Mains Switch and Power Socket
9
Power Button
9
LAN Socket
9
USB Sockets
9
Display Port Socket
9
Headband and Chin Rest
9
Replacement of the Headband
9
Replacement of the Chin Rest Tray
10
4 Operation
10
Position of Patient During Measurement
10
Fixation
10
Measured Variables
11
4.3.1 A-Scan
11
4.3.2 Keratometry
11
4.3.3 Topography, Elevation and Pachymetry
11
White to White Distance, Pupillometry and Eccentricity of the Visual Axis
11
5 Commissioning
11
Switching on the Device
11
Switching off the Device
11
6 Technical Data
11
General Data
11
Power
12
Illumination Modalities
12
6.3.1 OCT Light Source
12
6.3.2 Imaging System Light Source
12
6.3.3 Primary Fixation Targets
12
6.3.4 Fellow Eye Fixation Target
12
Measured Variables
12
Central Corneal Thickness (CCT)
12
Anterior Chamber Depth (ACD)
12
Lens Thickness (LT)
12
Simulated Posterior Keratometry (Simpk)
13
White-To-White Distance (WTW)
13
Pupillometry (PD)
13
Topography
13
7 Software / Help Menu / Error Messages
13
8 Maintenance
13
Cleaning
14
Appendix
14
Accessories / Consumables / Spare Parts / Upgrade
14
Legal Regulations
14
Classification
14
Disposal
15
Observed Standards
15
EMC Supplement
16
General
16
Emitted Interference (Standard Table 1)
16
Immunity (Standard Table 2)
17
Immunity on Non-Life Support Devices (Standard Table 4)
18
Safe Distances on Non-Life Support Devices (Standard Table 6)
19
Haag-Streit Eyestar 900 Instructions For Use Manual (25 pages)
Biometer
Brand:
Haag-Streit
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Safety
4
2 Introduction
9
3 Device Assembly / Installation
10
Power Button
11
LAN Socket
11
USB Sockets
11
Headband and Chin Rest
11
Replacement of the Headband
11
Replacement of the Chin Rest Tray
12
4 Operation
12
5 Commissioning
13
Switching on the Device
13
Switching off the Device
13
Illumination Modalities
14
OCT Light Source
14
Imaging System Light Source
14
Primary Fixation Target
14
Fellow Eye Fixation Target
14
Measured Variables
14
Central Corneal Thickness (CCT)
14
Anterior Chamber Depth (ACD)
14
Lens Thickness (LT)
14
6 Technical Data
14
Axial Length (AL)
15
Keratometry (K)
15
White-To-White Distance (WTW)
15
Pupillometry (PD)
15
Topography
15
Invivo Repeatability Standard Topography (7.5 MM Diameter)
15
Simulated Anterior Keratometry (Simk), Standard Topography (7.5 MM Diameter)
16
Simulated Posterior Keratometry (Simpk), Standard Topography (7.5 MM Diameter)
16
Invivo Repeatability Extended Topography (12 MM Diameter)
16
Simulated Anterior Keratometry (Simek), Extended Topography (12 MM Diameter)
17
Simulated Posterior Keratometry (Simepk), Extended Topography (12 MM Diameter)
17
Normative Considerations
17
Cristalline Lens Tilt
17
7 Software / Help Menu / Error Messages
17
8 Maintenance
18
Cleaning
18
¥ 9 Appendix
18
Accessories / Consumables / Spare Parts / Upgrade
18
Legal Regulations
19
Classification
19
Disposal
19
Observed Standards
19
Information and Manufacturer's Declaration Concerning Electromagnetic Compatibility (EMC)
19
General
19
Emitted Interference
20
Electromagnetic Immunity Environment Tested (Part 1)
21
Electromagnetic Immunity Environment Tested (Part 2)
22
Recommended Separation Distances between Portable and Mobile RF Communications Equipment and this Product
24
Advertisement
Advertisement
Related Products
Haag-Streit 320210
Haag-Streit 320220
Haag-Streit 320230
Haag-Streit 320240
Haag-Streit AT 900 BQ
Haag-Streit AT 900 R
Haag-Streit AT 900 T
Haag-Streit BP 900
Haag-Streit C.MOR HD
Haag-Streit C.MOR HD3
Haag-Streit Categories
Medical Equipment
Measuring Instruments
Diagnostic Equipment
Laboratory Equipment
Microscope
More Haag-Streit Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL