Sign In
Upload
Manuals
Brands
Gossen MetraWatt Manuals
Multimeter
METRAHIT IM E-DRIVE BT
Gossen MetraWatt METRAHIT IM E-DRIVE BT Manuals
Manuals and User Guides for Gossen MetraWatt METRAHIT IM E-DRIVE BT. We have
2
Gossen MetraWatt METRAHIT IM E-DRIVE BT manuals available for free PDF download: Operating Instructions Manual, Short-Form Operating Instructions
Gossen MetraWatt METRAHIT IM E-DRIVE BT Operating Instructions Manual (68 pages)
Insulation Tester, Milliohmmeter, TRMS Multimeter, Inter-Turn Short Circuit Tester
Brand:
Gossen MetraWatt
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Safety Instructions
5
2 Applications
6
Intended Use / Use for Intended Purpose
6
Use for Other than Intended Purpose
6
Liability and Guarantee
6
Opening the Instrument / Repairs
6
Manufacturer's Guarantee
6
3 Documentation
6
Product Variants
6
Firmware Version
6
Symbols
6
4 Operating Overview
7
Connections, Keys, Rotary Switch, Symbols (Depending on Instrument Variant)
7
Symbols Used in the Digital Display
8
Rotary Switch Position Symbols (Depending on Instrument Variant)
8
Symbols on the Instrument
9
5 Initial Startup
10
Battery Pack
10
Switching the Instrument on
11
6 System Settings
12
Digital Keyboard
12
Firmware
12
Language Selection
12
Time and Date Settings
12
Digital Display Settings
13
Brightness
13
Display Profile
13
Set Display of Leading Zeros
13
Configuring Password Protection
13
Selecting or Changing a Password
13
Deactivating Password Protection
13
Viewing the Instrument's Name
14
Installing a Functions Expansion
14
Switching the Instrument off
14
Switching the Instrument off Manually
14
Automatic Shutdown (Auto-Off)
14
Default Settings (Instrument Reset)
14
7 Control Functions
16
Help
16
Selecting Measuring Functions and Measuring Ranges
17
Automatic Range Selection
17
Manual Range Selection
17
Quick Measurements
17
Zero Offset / Relative Measurements
17
Display (TFT)
18
Digital Display
18
Analog Display
18
Measured Value Storage - Data Function (Auto-Hold/Compare)
18
Saving Minimum and Maximum Values - "Minmax
19
Measured Value Memory - STORE Function
20
Remote Read-Out and Storage Via the Z270S Probe (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT Only)
20
Remote Read-Out and Storage Via the PC - PUSH/PRINT Function
20
Measurement Data Recording
21
One-Time Only (Manual) Storage
21
Measurement Series (Automatic Storage)
21
Memory
23
8 Measurements
24
Enabling Parameter Changes
24
Insulation Resistance Measurement - RISO Function (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT Only)
24
Preparing for Measurement
24
Performing Insulation Measurement
26
Ending the Measurement and Discharging
26
Inter-Turn Short Circuit Measurement - COIL Function (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE Only)
26
Inter-Turn Short Circuit Measurement with the COIL TEST ADAPTER
26
Inter-Turn Short Circuit Measurement with the ADAPTER XTRA
30
Absorption Index Measurement - DAR (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT Only)
34
Polarization Index Measurement - PI (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT Only)
35
Voltage Measurement
36
Alternating Voltage and Frequency Measurement V AC and Hz with Selectable Low-Pass Filter
36
Duty Cycle Measurement - Duty AC (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT Only)
37
RPM Measurement - RPM AC (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE BT Only)
37
Direct and Pulsating Voltage Measurement, V DC and V (AC+DC)
39
Resistance Measurement
40
Capacitance Measurement F
41
Temperature Measurement with Resistance Thermometers - Temp RTD
42
Temperature Measurement with Thermocouple - Temp TC
43
Continuity Test
44
Diode Testing with Constant Current of 1 Ma
44
Milliohm Measurement - Rlo (2-Wire Measurement) (METRAHIT IM XTRA BT and METRAHIT IM E-DRIVE Only)
45
Milliohm Measurement - M/4 (4-Wire Measurement)
46
Compensation of Cable Resistance
46
Thermovoltage Compensation
47
Milliohm Measurement with 200 Ma or 20 Ma DC
48
Milliohm Measurement with 1 a Pulsating Measuring Current (Automatic Thermovoltage Correction at 3
48
Current Measurement
49
Direct and Pulsating Current Measurement, Direct Connection, - a DC and a (AC+DC)
49
Alternating Current and Frequency Measurement, Direct Connection, - AAC and Hz
50
Direct and Pulsating Current Measurement with Current Clamp Sensor - ADC und a (AC+DC)
51
Alternating Current Measurement with Current Clamp Sensor - AAC and Hz
52
Measuring Sequences - Test Sequences
53
9 Interface Operation and Software
56
Bluetooth
56
Software for Receiving and Evaluating Data
57
METRAHIT IM Data Reader (PC)
57
Terminal Program (PC)
57
METRALOG App (Smartphone and Tablet)
58
Sequence Manager: Software for Test Sequences
58
10 Characteristic Values
61
11 Maintenance and Calibration
65
Displays - Error Messages
65
Fuses
65
Housing Maintenance
65
Measurement Cables
65
Recalibration
65
12 Accessories
66
General
66
Technical Data for Measurement Cables (Included with KS17-2 Cable Set and Z270S Probe)
66
13 Returns and Environmentally Sound Disposal
66
14 CE Declaration
67
15 Addresses
68
Product Support
68
Recalibration Service
68
Repair and Replacement Parts Service Calibration Center * and Rental Instrument Service
68
Advertisement
Gossen MetraWatt METRAHIT IM E-DRIVE BT Short-Form Operating Instructions (36 pages)
Brand:
Gossen MetraWatt
| Category:
Multimeter
| Size: 1 MB
Table of Contents
Safety Instructions
9
Battery Control
15
Continuity Measurement
27
Diode Measurement
27
Advertisement
Related Products
Gossen MetraWatt METRAHIT ISO
Gossen MetraWatt METRAHIT ISO AERO
Gossen MetraWatt METRAHIT IM XTRA BT
Gossen MetraWatt METRAHIT IM TECH BT
Gossen MetraWatt METRAHIT IM E-DRIVE FUSO
Gossen MetraWatt METRAHIT MULTICAL
Gossen MetraWatt METRAHIT COIL
Gossen MetraWatt METRAHIT PM XTRA
Gossen MetraWatt METRAHIT AM TECH
Gossen MetraWatt METRAHIT ENERGY
Gossen MetraWatt Categories
Measuring Instruments
Test Equipment
Multimeter
Adapter
Controller
More Gossen MetraWatt Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL