Sign In
Upload
Manuals
Brands
Gossen MetraWatt Manuals
Multimeter
METRACLIP 86
Gossen MetraWatt METRACLIP 86 Multimeter Manuals
Manuals and User Guides for Gossen MetraWatt METRACLIP 86 Multimeter. We have
1
Gossen MetraWatt METRACLIP 86 Multimeter manual available for free PDF download: User Manual
Gossen MetraWatt METRACLIP 86 User Manual (51 pages)
CLAMP MULTIMETER
Brand:
Gossen MetraWatt
| Category:
Multimeter
| Size: 0 MB
Table of Contents
Table of Contents
2
Presentation
8
The Switch
9
The Keys of the Keypad
10
Item Function See
10
The Display Unit
11
The Symbols of the Display Unit
11
Measurement Capacity Exceeded (O.L)
13
The Terminals
13
The Keys
13
Key
13
Key (Second Function)
14
Key
15
In the Normal Mode
15
The MAX/MIN/PEAK Mode + Activation of the HOLD Mode
16
Access to the True-INRUSH Mode ( Set to )
17
Key
17
The Hz Function in the Normal Model
17
The Hz Function + Activation of the HOLD Mode
18
Key
18
Use
19
Commissioning
19
Starting up the Clamp Multimeter
20
Switching the Clamp Multimeter
20
Configuration
20
Programming of the Maximum Resistance Allowed for a Continuity
21
Activation of Automatic Switching off (Auto Power OFF)
21
Programming of the Current Threshold for the True INRUSH Measurement
21
Default Configuration
22
Voltage Measurement (V)
22
AC, DC, AC+DC Voltage Measurement (V)
22
Continuity Test
23
Automatic Compensation of the Resistance of the Leads
24
Resistance Measurement Ω
24
Diode Test
25
Current Measurement (A)
25
AC Measurement
25
AC, DC, AC+DC Current Measurement (A)
25
DC or AC+DC Measurement
26
Starting Current or Overcurrent (True Inrush) Measurement
27
Power Measurements W, Va, Var and Pf
27
Measurement of Single-Phase Power
28
Balanced Three-Phase Power Measurement
28
Direction of Rotation of the Phases" or "Order of the Phases" Mode
29
Frequency Measurement (Hz)
30
Frequency Measurement in Voltage
30
Frequency Measurement in Current
31
Measurement of Frequency in Power
31
Measurement of the Level of Harmonics (Thd) and of the Frequency of the Fundamental (Network)
32
Measurement of the THD and of the Frequency of the Fundamental in Voltage
32
Measurement of the THD and of the Frequency of the Fundamental in Current
32
Characteristics
34
Reference Conditions
34
Characteristics under the Reference Conditions
34
DC Voltage Measurement
34
AC Voltage Measurement
35
AC+DC Voltage Measurement
36
DC Current Measurement
36
AC Current Measurement
37
AC+DC Intensity Measurement
37
True-Inrush Measurement
38
Continuity Measurement
38
Resistance Measurement
38
Diode Test
39
Active DC Power Measurements
39
Active AC Power Measurements
40
Active AC+DC Power Measurements
41
Measurement of Apparent AC Power
42
Measurement of Apparent AC+DC Power
42
Measurement of Reactive AC Power
43
Measurement of Reactive AC+DC Power
43
Calculation of the Power Factor
44
Frequency Measurements
45
Characteristics in Thdr
45
Characteristics in Thdf
45
Indication of Order of the Phases
46
Environmental Conditions
46
Characteristics of Construction
47
Power Supply
47
Compliance with International Standards
47
Variations in the Domain of Use
48
Maintenance
49
Cleaning
49
Replacement of the Battery
49
Metrological Check
49
Repair
49
Warranty
50
Delivery Condition
50
Advertisement
Advertisement
Related Products
Gossen MetraWatt METRACAL MC
Gossen MetraWatt METRAHIT ENERGY TRMS System Multimeter
Gossen MetraWatt METRAHIT TECH
Gossen MetraWatt METRAHIT EBASE
Gossen MetraWatt METRA HIT H+E CAR
Gossen MetraWatt METRAHIT ULTRA
Gossen MetraWatt METRAHIT AM BASE
Gossen MetraWatt METRAHIT AM PRO
Gossen MetraWatt METRAHIT AM XTRA
Gossen MetraWatt METRAHIT PM TUNE
Gossen MetraWatt Categories
Measuring Instruments
Test Equipment
Multimeter
Adapter
Power Supply
More Gossen MetraWatt Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL