Sign In
Upload
Manuals
Brands
Gorenje Manuals
Air Conditioner
Aerogor POWER EVI Inverter 15 A
Gorenje Aerogor POWER EVI Inverter 15 A Manuals
Manuals and User Guides for Gorenje Aerogor POWER EVI Inverter 15 A. We have
2
Gorenje Aerogor POWER EVI Inverter 15 A manuals available for free PDF download: Installation Manual, User Manual
Gorenje Aerogor POWER EVI Inverter 15 A Installation Manual (97 pages)
Brand:
Gorenje
| Category:
Air Conditioner
| Size: 6 MB
Table of Contents
Installation Manual
1
Table of Contents
3
1 Before Use
8
Warnings
8
Disposal
10
Heating System Requirements (Mandatory)
10
Included in the Package
11
Technical Table
12
Aerogor Eco Compact Inverter 10A, 13A
12
Aerogor Eco Inverter 10A, 13A
13
Aerogor Power Evi Inverter 15A, 18A
14
Dimensions
15
Indoor Units
15
Outdoor Units
16
Operating Range
17
Working Principle
18
Main Components
19
Indoor Units
19
Outdoor Units
21
Aerogor Power Evi Inverter 15A/ 18A
23
2 Installation
24
Installation of the Indoor Unit
24
Installation of the Outdoor Unit
25
Foundation
27
Installation of C Profile and Legs
28
Instalation of the Refrigerant System (Split Type)
29
Height Difference between Indoor and Outdoor Unit
31
Instalation of Hydraulic Connections (Compact Type)
33
3 Electrical Wiring
34
Aerogor Eco Inverter 10A, 13A and Aerogor Power Evi Inverter 15A, 18A
34
Indoor Unit
34
Temperature Sensors
35
Connection between Indoor and Outdoor Unit
36
Aerogor Eco Compact Inverter 10A, 13A
37
Indoor Unit
37
Temperature Sensors
38
Connection between Indoor and Outdoor Unit
39
4 Control Unit
40
Description of Symbols on the Control Unit
40
Description of the Temperatures on the Control Unit
43
5 Quick Settings
44
Parallel Move of the Heating Curve
44
Setting the Parallel Move of the Heating Curve - Heating Circuit 1
44
Setting the Parallel Move of the Heating Curve - Heating Curve 2
45
Setting the Dhw Temperature
45
Setting the Fixed Temperature of Heating Circuit
46
Setting the Fixed Temperature for the First Heating Circuit
46
Setting the Fixed Temperature for the Second Heating Circuit
46
6 User Interface
47
Arrangment of Menus
47
Menu Access
47
Settings
48
Heating/Cooling Circuit 1
48
Heating/Cooling Circuit 2
52
Dhw Settings
54
Dhw Storage
56
Sanitary Hot Water Storage Function
57
Sanitary Hot Water Storage Timer
57
Reheating Function
57
Reheating Function Timer
57
Reheating Set Temp
57
Reheating Restart ∆T Setting
58
Reduced Setpoint
58
Temp. Drop/Rise
58
Timer for Reduced Setpoint Function
58
Quiet Operation
59
Allowable Temp. Drifting
59
Timer for Quiet Operation
59
Anti - Legionella
59
Anti - Legionella Program
59
Day and Time
60
Setpoint
60
Duration
60
Finish Time
60
Vacation Mode
60
Sanitary Hot Water Temp. Drop During Vacation Mode
61
Heating Water Temp. Drop During Vacation Mode
61
Vacation Start Date
61
Vacation Finish Date
61
User Management
61
Permission Level
61
Heating/Cooling ON/OFF Timer
61
Language
62
Set Date and Time
62
Distribution System Setting
62
Save Current Settings
62
Load Saved Settings
62
Switch to Factory Settings
62
Mode Settings
63
Sanitary Hot Water
63
Heating
63
Cooling
63
Basic Operation Modes
63
Cooling and Heating Switch
64
Ambient Temp. to Start Heating
64
Ambient Temp. to Start Cooling
65
Backup Heating
65
Backup Heating Sources for Heating
66
Priority for Backup Heating Sources (HBH)
66
Backup Heating Source for Sanitary Hot Water
67
Priority for Backup Heating Sources (HWTBH)
67
Heating Source Start Accumulating Value (HBH)
67
Water Temperature Rise Reading Interval (Hwtbh)
67
Emergency Operation
67
Water Pump Settings
68
Circulation Pump P0 Type
68
Speed Setting of Circulation Pump P0
69
Working Mode of Circulation Pump P0
69
Pump off Interval for P0
69
Pump on Time for P0
69
Buffer Tank
69
P1 for Heating Operation
69
P1 for Cooling Operation
69
P1 with High Temp. Demand
69
P2 for Heating Operation
69
P2 for Cooling Operation
70
P2 with High Temp. Demand
70
Floor Curing
70
Floor Curing
71
Floor Curing Current Stage
71
Floor Curing Current Stage Running Duration
71
Floor Curing Current Stage Set Temperature
71
Floor Curing Current Stage Valid Running Duration
71
Floor Current Total Running Duration
71
Highest Water Temp. in Floor Curing Operation
71
Electrical Utility Lock
72
Operation Signal for Electrical Utility Lock
73
HBH During Electrical Utility Lock
73
P0 During Electrical Utility Lock
73
Heating Eco Operation
73
Ambient Temp. to Start Heating Eco Operation
73
Other Options
74
Motorized Diverting Valve Switching Time
74
Power on Time for Motorized Diverting Valve
74
Refrigerant Recycle Function
74
Control Panel Backlight Light
74
Exit System
75
Anti-Freezing Protection
75
Mode Switch During Defrosting
75
Mode Signal Output
75
Mode Signal Type
75
Fan Speed Limit
75
Defrosting Logic Selection
76
Activate Wi-Fi Module or Not
76
Accept Setting from Wi-Fi Module
76
Connection to the Server
76
Connection to the Router
76
Mac
76
WI-FI Module IP Address
76
Ssid
76
Password
76
Server Address
76
Unit Real-Time Data
77
7 Error Codes
77
Error Codes Shown on the Display
77
Error Code Menu
77
Accessing the Error Code Menu
77
Informations in the Error Code Menu
78
Info Page
78
Error Code List
80
8 Cleaning the Magnetic/Dirt Filter Caleffi
86
9 Water Pressure in the System
87
10 Wiring
88
Indoor Unit - All Inverters
88
Indoor Unit Terminals - Eco10A,13A, Power Evi 15A, 18A
90
Outdoor Pcb Eco Inverter
91
Drive for Eev
93
Outdoor Unit - Power Evi Inverter 15A, 18A
94
Outdoor Unit Drive - Aerogor Power Evi 15A, 18A
96
Advertisement
Gorenje Aerogor POWER EVI Inverter 15 A User Manual (53 pages)
Inverter
Brand:
Gorenje
| Category:
Heat Pump
| Size: 3 MB
Table of Contents
Table of Contents
3
1 Before Use
7
Safety Warnings
7
2 Principle of Operation of the Heat Pump
9
The Basic Principle of Operation of a Heat Pump
9
Inverter Heat Pump
9
Optimisation of Heating Costs
9
Selection of Heat Pump
9
Heating Curve
9
Domestic Water
9
In Time of Absence
10
3 How to Make Small Changes to Reduce Heating Costs
10
4 Emergency Operation
12
Location of the Emergency Switch
14
5 Control Unit
16
Description of Symbols on the Control Unit
16
Description of Temperatures on the Control Unit
19
6 Rising / Lowering the Room Temperature
20
Exclusively According to Ambient Tepperature
20
Combination of Ambient Temperature and Room Temperature
20
7 Quick Settings
21
Setting the Parallel Move of the Heating Curve - Heating
21
Circuit 1
21
Setting the Parallel Move of the Heating Curve - Heating
22
Curve 2
22
Setting the Dhw Temperature
22
Setting the Fixed Temperature of Heating Circuit
23
Setting the Fixed Temperature for the First Heating Circuit
23
Setting the Fixed Temperature for the Second Heating Circuit
23
8 User Interface
24
Arrangment of Menus
24
Menu Access
24
9 Settings
25
Heating/Cooling Circuit 1
25
Heating/Cooling Stops Based on Water ∆T
26
Heating/Cooling Restarts Based on ∆T
26
T Compressor Speed Reduction
26
Set Temp. for Cooling
26
Heating Curve
26
Setting the Heating Curve for the First Heating Circuit
27
Room Temp. Effect on Heating Curve
28
Ideal Room Temp. in Heating
28
Ideal Room Temp. in Cooling
28
Set Temperature for Heating - Without Heating Curve
28
Low Temperature Limit
28
High Temperature Limit
28
Mixing Valve
28
Heating/Cooling Circuit 2
29
Set Temp. for Cooling
29
Set Temp. for Heating - Without Heating Curve
29
Mixing Valve
29
Heating Curve
30
Setting the Heating Curve for the Second Heating Circuit
31
Dhw Settings
31
Setpoint DHW
32
DHW Restart ∆T Setting
32
Shifting Priority
32
Enabling or Disabling the Shifting Priority Function
32
Shifting Priority Starting Temperature
32
Sanitary Water Min. Working Hours
32
Heating Max. Working Hours
32
Allowable Temp. Drift in Heating
33
DHW Backup Heater for Shifting Priority
33
DHW ECO Operation
33
Ambient Temp. to Start DHW ECO Operation
33
Dhw Storage
33
Sanitary Hot Water Storage Function
33
Sanitary Hot Water Storage Timer
33
Reheating Function
34
Reheating Function Timer
34
Reheating Set Temp
34
Reheating Restart ∆T Setting
34
Reduced Setpoint
35
Temp. Drop/Rise
35
Timer for Reduced Setpoint Function
35
Quiet Operation
35
Allowable Temp. Drifting
36
Timer for Quiet Operation
36
Anti - Legionella
36
Anti - Legionella Program
36
Day and Time
37
Setpoint
37
Duration
37
Finish Time
37
Vacation Mode
38
Sanitary Hot Water Temp. Drop During Vacation Mode
38
Heating Water Temp. Drop During Vacation Mode
38
Vacation Start Date
38
Vacation Finish Date
38
User Management
39
Permission Level
39
Heating/Cooling ON/OFF Timer
39
Language
39
Set Date and Time
39
Distribution System Setting
39
Save Current Settings
39
Load Saved Settings
39
Switch to Factory Settings
40
Mode Settings
40
Ambient Temp. to Start Heating
40
Ambient Temp. to Start Cooling
41
Backup Heating
41
Water Pump Settings
42
Floor Curing
42
Electrical Utility Lock
42
Other Options
43
Unit Real-Time Data
43
10 Error Codes
44
Error Codes Shown on the Display
44
Error Code Menu
44
Accessing the Error Code Menu
44
Informations in the Error Code Menu
44
Info Page
45
Error Code List
47
11 Cleaning the Magnetic / Dirt Filter Caleffi
51
12 Water Pressure in the System
52
Advertisement
Related Products
Gorenje Aerogor ECO COMPACT INVERTER 10A
Gorenje Aerogor ECO COMPACT INVERTER 13A
Gorenje Aerogor POWER EVI Inverter 18 A
Gorenje TGR 150 NGC6
Gorenje Aerogor POWER 15AS
Gorenje GBFU 150 E/V6
Gorenje GBU 150 EDD/V6
Gorenje GBU 150 EDD/V9
Gorenje GBFU 120 E/V6
Gorenje 1S40BF 2E ASC B
Gorenje Categories
Ventilation Hood
Refrigerator
Dishwasher
Microwave Oven
Hob
More Gorenje Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL