Sign In
Upload
Manuals
Brands
Giken Manuals
Controller
GSK-IF-N1
Giken GSK-IF-N1 Manuals
Manuals and User Guides for Giken GSK-IF-N1. We have
1
Giken GSK-IF-N1 manual available for free PDF download: Instruction Manual
Giken GSK-IF-N1 Instruction Manual (131 pages)
Brand:
Giken
| Category:
Controller
| Size: 11 MB
Table of Contents
Table of Contents
4
1 System out Line
8
1-1 GSK System out Line
8
1-2 GSK Controller Section
8
1-3 GSK if Unit Section
8
1-4 GSK AC Nut Runner Section
9
1-5 GKL System out Line
10
1-6 GKL Controller Section
10
1-7 GKL if Unit Section
10
1-8 GKL AC Nut Runner Section
11
2 Specifications
12
2-1 Specifications of Controller
12
2-2 Basic Specification
14
2-2-1 GSK Basic Specification
14
2-2-1 GKL Basic Specification
19
2-3 Functions/Features
21
7Segment Led
21
2-4 Size
22
2-4-1 Interface Dimensions:standard Type・・・Gsk-IF/GKL-IF
22
2-4-2 Controller Dimensions:standard Type・・・Gsk-14/GKL-14
23
2-4-3 Controller Dimensions:standard Type・・・Gsk-15/GKL-15
24
2-4-4 Controller Dimensions:standard Type・・・Gsk-17/GKL-17
25
2-4-5 Controller Dimensions:standard Type・・・Gskw-14/GKLW-14
26
2-4-6 Controller Dimensions:standard Type・・・Gskw-15/GKLW-15
27
2-4-7 Controller Dimensions:t Type・・・Gsk-T4/GKL-T4
28
2-4-8 Controller Dimensions:t Type・・・Gsk-T5(T7)/GKL-T5(T7
29
2-4-9 Controller Dimensions:t Type・・・Gskw-T4/GKLW-T4
30
2-4-10 Controller Dimensions:t Type・・・Gskw-T5/GKLW-T5
31
2-4-11 Dimensions(Display) : Model ・・・GSK-D2/GKL-D2
32
3 Wire Connection
33
3-1 Wiring Reference Diagram
33
3-1-1 GSKW/GKLW Controller System Wiring Reference Diagram
33
3-1-2 GSK/GKL Controller System Wiring Reference Diagram
34
3-2 Used Connector and Mating Connector
35
3-2-1 GSK/GKL Used Connector and Mating Connector
35
3-2-2 Interface Communication Port Details
36
3-3 Connection to the Outside
37
3-3-1 External Connection Diagram(Controller~Nr):Standard and T Type
37
3-3-2 External Connection Diagram(I/F Unit~Connected Equipment):Standard and T Type
37
3-4 Cable Model List
39
3-4-1 GSK Cable Model List
39
3-4-2 GSKW Cable Model List
40
4 Signal
41
4-1 Signal Type
41
4-2 Input and Output Signals
42
4-2-1 Input and Output Signals
42
4-2-2 Output Signal
44
4-3 Input & Output Signal Map
46
4-4 Sequencerselected
47
4-4-1 Extender Board Setting Method
47
5 Operation Timing Chart
48
5-1 Power on and Inching Operation
48
5-2 Program Operation -2 Step Operation ①
48
5-3 Program Operation -2 Step Operation ②
49
5-4 Program Operation -2 Step Operation③
50
5-5 Program Operation -1Step Operation①
52
5-6 Program Operation -1Step Operation②
52
5-7 Program Operation --2 Step Operation④
53
5-8 Program Operation -1Step Operation③
55
5-9 Interruption of Program Operation(Reset
56
5-10 Operation Preparation off and Program Start off in the Program Operation
57
5-11 Alarm and Alarm Reset in the Program Operation
57
5-12 Tightening Angle Sampling Operation
58
6 Setting
60
6-1 Display / Setting Function
60
6-1-1 View of the Display Unit
60
6-1-2 Operation the Display Unit
61
6-1-3 Setting Example
62
6-1-4 Procedure for Setting Axis Number
62
6-1-5 Procedure to Erase the 7 Segment Display of W Type Unused Axis
64
6-1-6 Procedure of Changed Tightening Sampling Stop Torque
65
6-2 Program
66
7 Setting Function Details
67
7-1 Fn. ** Display Setting Function List
67
7-2 (D-00***, D-10***)Each-Axis Setting, Driver Parameter Setting
68
7-3 Socket-Fittings Setting
70
7-4 Pre-Tightenings Setting
71
7-5 Revese Tightening Setting
74
7-6 Real Tightening Setting
76
7-7 Rate Setting
81
7-8 X-Axis Rate Setting
86
7-9 Y-Axis Rate Setting
88
7-10 Point Setting
89
7-11 (Fn.01) Tightening Result Monitor of the 1Th Axis
90
7-12 (Fn.02) Tightening Result Monitor of the 2Th Axis
90
7-13 (Fn.03) Input and Output Monitor
91
7-14 (Fn.04)Operation Instruction from GSK/GKL Drive
92
7-15 (Fn.5) Unit Setting
92
7-16 (Fn.6) Interface Unit Setting
93
7-17 (Fn.7) ID Controller Connection Setting
95
8 Supplementary Explanation
97
8-1 Operation Auxiliary Function
97
8-2 Driver Function
97
9 Monitor Output
98
10 Code Table
99
10-1 NG Code List
99
10-2 Alarm Code List
101
11 Indication on the Display
105
12 Maintenance and Check
112
12-1 Prrecautions
112
12-1-1 Precautions for Maintenance and Check
112
12-1-2 Check Items
112
12-1-3 Operating Life
112
12-1-4 Capacitor
113
12-1-5 Relay
113
12-1-6 Cooling Fan
113
12-1-7 Battery
113
12-1-8 E2Prom
113
12-2 Guarantee
113
12-3 Tightening Operation Glossary
113
13 Supplemental Explanation
116
13-1 Precautions for Wiring the Arc Net
116
13-2 about GSK/GKL Tightening Setting Additional Items
117
13-2-1 Judgment Area
117
13-2-2 Smooth Tightening
117
13-3 SD Card
118
13-3-1 Automatic Storage of Tightening Result
119
13-4 Predictive Maintenance Function
121
13-4-1 Outline of Predictive Maintenance
121
13-4-2 Flow to Alarm Notification
122
13-4-3 GSK/GKL Controller Electronic Component Lifetime Warning
122
13-4-4 Nut Runner Failure Prediction Warning
123
13-5 Precautions for Input/Outout Communication
124
Input ENABLE
124
13-6 Precautions to Read History
125
13-7 Items of Setting Possible and Setting Not Possible
125
13-8 about Connection Setting of ID Controller
126
13-8-1 Outline
126
13-8-2 Secification of Communication
126
13-8-3 Ressive Format(Plc → Interface Unit
126
13-8-4 Transmission Format (Interface Unit → PLC
126
13-8-5 Select with Condition of Starting Transmission
127
13-8-6 Selecting Transmission Data
128
13-9 about Installation
129
13-9-1 about Installation
129
13-9-2 Standard Specification
129
13-9-3 T Specification
129
Update Log
130
Advertisement
Advertisement
Related Products
Giken GSK-IFCC-N1
Giken GSK-IFDN-N1
Giken GSK-IFET-N1
Giken GSK-IFPNIO-N
Giken GSK-IFPNIRT-N1
Giken GSK-IFSG-N1
Giken GSK-IFSG2-N1
Giken GSKW-T5
Giken GSK Series
Giken GSK
Giken Categories
Controller
Power Tool
More Giken Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL