Sign In
Upload
Manuals
Brands
Güralp Manuals
Measuring Instruments
Minimus2
Güralp Minimus2 Manuals
Manuals and User Guides for Güralp Minimus2. We have
3
Güralp Minimus2 manuals available for free PDF download: Technical Manual
Güralp Minimus2 Technical Manual (102 pages)
Brand:
Güralp
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
2
Preliminary Notes
6
Proprietary Notice
6
Cautions and Notes
6
Manuals and Software
6
Conventions
6
System Overview
7
Key Features
7
Typical Applications
7
System Description
9
Güralp Minimus Digitiser
9
LED Indicator
9
Bluetooth Connectivity
10
Data Storage
10
Web Interface
12
Accessory Package
12
Ethernet Cable
12
Compact GNSS Receiver and Cable
13
Power Cable
13
Diagnostic GNSS to Serial Cable Adapter
13
Güralp Discovery Software
15
Güralp GüVü Android and Ios App
16
Getting Started
17
System Set-Up
17
Güralp Discovery Software Installation
17
Viewing Waveforms and System State-Of-Health
19
Using Discovery's "Live View" Window
19
Using Scream
22
System Configuration
24
Web Page Login
24
System Status
25
Station Meta-Data
26
Network Configuration
26
IP Address and Gateway
26
NTP (Network Timing Protocol) Configuration
27
GDI Push (Auto-Connection)
28
Data Storage
28
Storage
29
Recording Status
29
Microsd Card Re-Formatting
30
Microsd Card Data Flushing and Unmounting
31
Downloading Recorded Data
31
Downloading Data for Specific Time-Intervals
32
Bulk Data Extraction
32
The Contents of the Microsd Card
33
Request Data from Microsd Card
34
Data Transmission
35
Scream! (GCF Format + Scream Protocol)
36
GDI-Link Protocol
37
Seedlink Protocol
37
Synchronisation of the Sample-Clock
40
GNSS Lock Status
41
PTP (Precision Time Protocol)
41
Deploy Mode: Full Power-Save
43
Configuration and Control of Connected Analogue Instruments
45
Setting Instrument Type
45
Setting Instrument (Sensor) Gain for Güralp Fortis
45
Setting Digitiser Gain
46
Mass Control
46
Instrument Response Parameters
47
Configuration and Control of Connected Digital Instruments
49
Setting Sensor Orientation and Depth Parameters
50
Applied Rotation
50
Instrument Installation Parameters
50
Inject a Calibration Signal
50
Earthquake Early Warning
51
Trigger Configuration
52
EEW Configuration
52
CAP Receiver
53
Seismic Event Table
55
Using a Registry
55
Configuring a Minimus2 for Use with a Registry
56
Configuring Discovery for Use with a Registry
56
Registry Mode: Using WAN or LAN Addresses
57
Updating Minimus2 Firmware
58
Import / Export an Existing Configuration
59
Control Centre
59
GüVü App
61
Getting Stated
61
Selecting Data Sources
62
View Settings
62
Instrument Control
62
Setting the PIN Code
63
Emailing a Deployment Report
63
Bulk Data Extraction Via Network
64
Time Based Data Extraction Via Network
64
Bulk Data Extraction
65
The Contents of the Microsd Card
66
Advanced Troubleshooting
68
Reset All Settings During Boot Phase
69
Appendix 1 - Instrument/Channel Names
75
Minimus2 ' Internal Sensors
76
Analogue Instruments
77
Digital Instruments
79
Appendix 2 - Minimus2 Network Ports
81
Appendix 3 - Connector Pin-Outs
82
Ethernet
82
Power
83
Gnss/Serial
84
Digital
85
Analogue 1 and Analogue 2
86
Appendix 4 - Dimensions and Drawings
87
Minimus
87
Minimus
88
Appendix 5 - Güralp Discovery Installation
89
Installation in Linux
89
Installation in Mac
90
Installation in Windows
91
Configuring Windows Firewall
94
Update
95
Appendix 6 - IP Address Configuration on PC or Laptop
98
On Linux
98
On Macos
98
On Windows
100
EU Declaration of Conformity
101
Revision History
102
Advertisement
Güralp Minimus2 Technical Manual (84 pages)
Brand:
Güralp
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
2
Preliminary Notes
6
Proprietary Notice
6
Cautions and Notes
6
Manuals and Software
6
Conventions
6
System Overview
7
Key Features
7
Typical Applications
7
System Description
8
Güralp Minimus
8
LED Indicator
8
Digitiser
8
Bluetooth Connectivity
8
Data Storage
9
Web Interface
10
Accessory Package
11
Ethernet Cable
11
Compact GNSS Receiver and Cable
11
Power Cable
11
Diagnostic GNSS to Serial Cable Adapter
12
Güralp Discovery Software
13
Güralp GüVü Android and Ios App
14
Getting Started
15
System Set-Up
15
Güralp Discovery Software Installation
15
Viewing Waveforms and System State-Of-Health
17
Using Discovery's "Live View" Window
17
Using Scream
20
System Configuration
22
Web Page Login
22
System Status
22
Data Streams
23
Station Meta-Data
24
Network Configuration
24
IP Address and Gateway
24
NTP (Network Timing Protocol) Configuration
25
GDI Push (Auto-Connection)
25
Data Storage
26
Storage
27
Recording Status
27
Microsd Card Data Flushing and Unmounting
29
Downloading Recorded Data
29
Downloading Data for Specific Time-Intervals
30
Bulk Data Extraction
30
The Contents of the Microsd Card
31
Time Based Download Via Network
33
Request Data from Microsd Card Via Network
33
Data Transmission
34
Scream! (GCF Format + Scream Protocol)
34
GDI-Link Protocol
35
Seedlink Protocol
36
Synchronisation of the Sample-Clock
39
GNSS Lock Status
39
PTP (Precision Time Protocol)
39
Deploy Mode: Full Power-Save
40
Configuration and Control of Connected Analogue Instruments
41
Setting Instrument Type
41
Setting Instrument (Sensor) Gain for Güralp Fortis
41
Setting Digitiser Gain
41
Mass Control
42
Instrument Response Parameters
43
Configuration and Control of Connected Digital Instruments
46
Inject a Calibration Signal
46
Earthquake Early Warning
47
Trigger Configuration
47
EEW Configuration
48
CAP Receiver
48
Seismic Event Table
50
Using a Registry
51
Configuring a Minimus
51
For Use with a Registry
51
Configuring Discovery for Use with a Registry
52
Registry Mode: Using WAN or LAN Addresses
53
Updating Minimus
54
Import / Export an Existing Configuration
54
Firmware
54
Control Centre
55
GüVü App
57
Getting Started
57
Selecting Data Sources
57
View Settings
58
Instrument Control
58
Setting the PIN Code
59
Emailing a Deployment Report
59
Advanced Troubleshooting
60
Reset All Settings During Boot Phase
61
Appendix 1 - Instrument/Channel Names
62
Appendix 2 - Digital Interconnectivity and Devices
63
Appendix 3 - Network Ports
64
Appendix 4 - Connector Pin-Outs
65
Ethernet
65
Power
65
Gnss/Serial
67
Digital
67
Analogue 1 and Analogue
68
Appendix 5 - Dimensions and Drawings
70
Appendix 6 - Güralp Discovery Installation
71
Installation in Linux
71
Installation in Mac
72
Installation in Windows
73
Configuring Windows Firewall
75
Update
77
Appendix 6 - IP Address Configuration on PC or Laptop
80
On Linux
80
On Macos
80
On Windows
82
Güralp Minimus2 Technical Manual (77 pages)
Brand:
Güralp
| Category:
Data Loggers
| Size: 4 MB
Table of Contents
Table of Contents
2
Preliminary Notes
6
Proprietary Notice
6
Cautions and Notes
6
Manuals and Software
6
Conventions
6
System Overview
7
Key Features
7
Typical Applications
7
System Description
8
Güralp Minimus2 Digitiser
8
LED Indicator
8
Bluetooth Connectivity
8
Data Storage
9
Web Interface
10
Accessory Package
11
Ethernet Cable
11
Compact GNSS Receiver and Cable
11
Power Cable
11
Diagnostic GNSS to Serial Cable Adapter
12
Güralp Discovery Software
13
Güralp GüVü Android App
14
Getting Started
15
System Set-Up
15
Güralp Discovery Software Installation
15
Viewing Waveforms and System State-Of-Health
16
Using Discovery's "Live View" Window
16
Using Scream
19
Web Page Login
21
System Status
21
Data Streams
22
Low Bandwidth Considerations
22
Station Meta-Data
23
Network Configuration
23
IP Address and Gateway
23
NTP (Network Timing Protocol) Configuration
24
GDI Push (Auto-Connection)
24
Data Storage
25
Storage
26
Recording Status
26
Quick Format
27
Microsd Card Data Flushing and Unmounting
27
Downloading Recorded Data
28
Downloading Data for Specific Time-Intervals
28
Bulk Data Extraction
29
The Contents of the Microsd Card
29
Time Based Download Via Network
32
Request Data from Microsd Card Via Network
33
Data Transmission
34
Scream! (GCF Format + Scream Protocol)
35
GDI-Link Protocol
35
Seedlink Protocol
36
Synchronisation of the Sample-Clock
39
GNSS Lock Status
39
PTP (Precision Time Protocol)
40
Configuration and Control of Connected Analogue Instruments
40
Setting Instrument Type
40
Setting Instrument (Sensor) Gain for Güralp Fortis
40
Setting Digitiser Gain
41
Mass Control
41
Instrument Response Parameters
42
Configuration and Control of Connected Digital Instruments
46
Inject a Calibration Signal
46
Earthquake Early Warning
47
Trigger Configuration
47
EEW Configuration
48
CAP Receiver
48
STA/LTA Streams
50
Seismic Event Table
51
Using a Registry
52
Configuring a Minimus2 for Use with a Registry
52
Configuring Discovery for Use with a Registry
53
Registry Mode: Using WAN or LAN Addresses
54
Updating Minimus2 Firmware
55
Import / Export an Existing Configuration
56
Scripting
56
Enabling Scripting Capability
56
Preparing the Script File
57
Sending a Script File
60
Status of the Script Running Process
61
GüVü App
62
Getting Started
62
Selecting Data Sources
62
View Settings
63
Instrument Control
63
Setting the PIN Code
64
Emailing a Deployment Report
64
Using Guralp's Power Pack Module
65
Advanced Troubleshooting
66
Reset All Settings During Boot Phase
67
Appendix 1 - Instrument/Channel Names
68
Appendix 2 - Digital Interconnectivity and Devices
69
Appendix 3 - Network Ports
70
Appendix 4 - Connector Pin-Outs
71
Ethernet
71
Power
72
Gnss/Serial
73
Digital
74
Analogue 1 and Analogue 2
74
Analogue Port
74
EU Declaration of Conformity
76
Advertisement
Advertisement
Related Products
Güralp Minimus+
Güralp Minimus
Güralp Minimus Lite
Güralp 5T
Güralp Affinity
Güralp Certimus
Güralp CMG-3ESP
Güralp CMG-5TD
Güralp CMG-EDU
Güralp DM24 MkIII
Güralp Categories
Measuring Instruments
Accessories
Data Loggers
Extender
More Güralp Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL