Sign In
Upload
Manuals
Brands
Fujitsu Manuals
Air Conditioner
AIRSTAGE ABEG18KRTA
Fujitsu AIRSTAGE ABEG18KRTA Manuals
Manuals and User Guides for Fujitsu AIRSTAGE ABEG18KRTA. We have
4
Fujitsu AIRSTAGE ABEG18KRTA manuals available for free PDF download: Design & Technical Manual, Service Manual
Fujitsu AIRSTAGE ABEG18KRTA Design & Technical Manual (440 pages)
3-unit multi-split type
Brand:
Fujitsu
| Category:
Air Conditioner
| Size: 21 MB
Table of Contents
Table of Contents
3
Part 1. INDOOR UNIT
9
Model Lineup
10
Connectable Indoor Units to each Outdoor Unit
12
Indoor Unit Connection Patterns
13
Specifications
16
Compact Cassette Type
16
Mini Duct Type
18
Slim Duct Type
20
Medium Static Pressure Duct Type
22
Wall Mounted Type
23
Ceiling Type
28
Floor Type
29
Wireless LAN Control (for KMCG, KMCG-B, KETF, KETF-B, KGTG, and KNCA)
30
System Requirement
30
Wireless Router
30
Dimensions
31
Compact Cassette Type
31
Installation Space Requirement
32
Mini Duct Type
33
Maintenance Space Requirement
35
Slim Duct Type
36
Medium Static Pressure Duct Type
39
Wall Mounted Type
42
Ceiling Type
53
Floor Type
55
Installation Space
56
Wiring Diagrams
57
Compact Cassette Type
57
Mini Duct Type and Slim Duct Type
58
Medium Static Pressure Duct Type
59
Wall Mounted Type
60
Ceiling Type
65
Floor Type
66
Air Velocity and Temperature Distributions
67
Compact Cassette Type
67
Mini Duct Type
74
Slim Duct Type
84
Wall Mounted Type
94
Ceiling Type
101
Floor Type
102
Fan Performance
103
Mini Duct Type
103
Slim Duct Type
113
Medium Static Pressure Duct Type
123
Fan Performance Curve
123
Compact Cassette Type
129
Mini Duct Type
130
Slim Duct Type
131
Medium Static Pressure Duct Type
132
Wall Mounted Type
133
Ceiling Type
136
Floor Type
137
Noise Level Curve
138
Compact Cassette Type
138
Mini Duct Type
141
Slim Duct Type
144
Medium Static Pressure Duct Type
147
Wall Mounted Type
149
Ceiling Type
157
Floor Type
158
Sound Level Check Point
160
Electrical Characteristics
163
Input Power
164
Safety Devices
165
External Input and Output
167
12-1.Compact Cassette Type, Medium Static Pressure Duct Type, and Ceiling Type
167
Indoor Unit
168
External Input and Output PCB
168
Input Signal Type
169
External Output
170
Function Setting
173
Operation/Stop Mode
174
Forced Thermostat off
175
Rotary Switch
175
Input Signal
175
Error Status
176
Indoor Unit Fan Operation Status
177
External Input and Output
178
12-2.Mini Duct Type and Slim Duct Type
178
Combination of External Input and Output
180
Control Output Function
182
External Heater Output
183
12-3.Wall Mounted Type (KMCG, KMCG-B, KETF, KETF-B, KGTG, and KMTE)
184
Input Select
186
Function Setting
189
Output Signal
195
12-4.Floor Type
197
Auxiliary Heater Control
205
Operation
205
Group Connection
206
Remote Controller
207
14-1.Wireless Remote Controller (AR-REW4E and AR-REJ1E)
207
14-2.Wireless Remote Controller (AR-REW3E)
210
14-3.Wireless Remote Controller (AR-REW2E)
212
14-4.Wireless Remote Controller (AR-REM7E)
214
14-5.Wireless Remote Controller (AR-RMB1E and AR-RMB1E-B)
216
Remote Controller (UTY-LBTYM or UTY-LBTYH: Optional Part)
218
WLAN Button
221
14-7.Wireless Remote Controller (AR-RPF4E)
221
14-8.Wired Remote Controller (UTY-RNNYM: Optional Part)
223
System Diagram
224
Electrical Wiring
224
Wiring Specifications
225
Installation
225
14-9.Wired Remote Controller (UTY-RVRY : Optional Part)
226
System Diagrams
228
Remote Controller
229
Group Control
230
Installation Space
231
On/Off Button
236
Display Panel
236
14-10.Wired Remote Controller (UTY-RLRY: Optional Part)
236
14-11.Wired Remote Controller (UTY-RVNYM: Optional Part)
239
Controller Combination
240
Installation Procedures
242
14-12.Wired Remote Controller (UTY-RNRYZ*: Optional Part)
246
14-13.Wired Remote Controller (UTY-RCRYZ1: Optional Part)
249
14-14.Simple Remote Controller (UTY-RSNYM: Optional Part)
253
Mode Button
253
Standby Indicator
253
14-15.Simple Remote Controller (UTY-RSRY and UTY-RHRY: Optional Parts)
256
Function Settings
259
15-1.Compact Cassette, Mini Duct, Slim Duct Types Indoor Unit (Setting by DIP Switch)
259
Component Location
259
Dip Switch Setting
260
15-2.Medium Static Pressure Duct Type
261
15-3.Indoor Unit (Setting by Wireless Remote Controller)
262
15-4.Indoor Unit (Setting by Wired Remote Controller)
282
Setting Procedure by Using Wired Remote Controller
285
15-5.Indoor Unit (Setting by Simple Remote Controller)
295
Function Setting List
302
15-6.Function Details
302
Filter Sign
303
Factory Setting
306
Auto Restart
307
15-7.Wired Remote Controller (UTY-RNNYM)
310
Switch Location
310
15-8.Wired Remote Controller (UTY-RVNYM)
312
15-9.Wired Remote Controller (UTY-RLRY)
313
15-10.Wired Remote Controller (UTY-RNRYZ*)
313
15-11.Simple Remote Controller (UTY-RSNYM)
314
Accessories
315
16-1.Compact Cassette Type
315
16-2.Mini Duct Type
316
16-3.Slim Duct Type
318
16-4.Medium Static Pressure Duct Type
319
16-5.Wall Mounted Type
320
16-6.Ceiling Type
323
16-7.Floor Type
324
Optional Parts
325
17-1.Controllers
325
17-2.Cassette Grille
329
17-3.Others
330
Indoor Unit Installation Precautions
336
18-1.Places Where Prohibited for Use
336
18-2.Points to Remember When Installing
336
Part 2. OUTDOOR UNIT (3 UNITS TYPE)
339
Specifications
340
Dimensions
342
Models: AOEG18KBCA3 and AOEG24KBCA3
342
Installation Space
343
Models: AOEG18KBCA3 and AOEG24KBCA3
343
Space Requirement
343
Single Outdoor Unit Installation
343
Multiple Outdoor Unit Installation
344
Outdoor Units Installation in Multi-Row
345
Refrigerant Circuit
346
Models: AOEG18KBCA3 and AOEG24KBCA3
346
Wiring Diagram
347
Models: AOEG18KBCA3 and AOEG24KBCA3
347
Capacity Table
348
Combinations
348
Cooling Capacity
355
Compact Cassette Type
358
Mini Duct Type
359
Slim Duct Type
360
Wall Mounted Type
362
Floor Type
366
Compact Cassette Type
371
Mini Duct Type
373
Slim Duct Type
375
Wall Mounted Type
378
Heating Capacity
385
Capacity Compensation Rate for Pipe Length and Height Difference
414
Models: AOEG18KBCA3 and AOEG24KBCA3
414
Additional Charge Calculation
417
Model: AOEG18KBCA3
417
Model: AOEG24KBCA3
417
Airflow
418
Model: AOEG18KBCA3
418
Model: AOEG24KBCA3
418
Operation Noise (Sound Pressure)
419
10-1.Noise Level Curve
419
10-2.Sound Level Check Point
420
Electrical Characteristics
421
Safety Devices
422
Function Settings
423
13-1.Setting Methods
423
Setting Method
424
Description of Display
425
13-2.Outdoor Unit Low Noise Operation Function (Option)
426
13-3.Current Limit Function
426
Check and Test
427
Restrictions Applicable When Performing the Check Run
427
Things to Confirm before Starting the Check Run
427
Operating Procedure for Check Run
428
14-2.Test Run
433
14-3.Error Code
434
Error Code Display
435
Error Type
436
Pump down Operation
437
Accessories
439
15-1.Model: AOEG18KBCA3
439
15-2.Model: AOEG24KBCA3
439
Outdoor Unit Installation Precautions
440
Advertisement
Fujitsu AIRSTAGE ABEG18KRTA Service Manual (210 pages)
Brand:
Fujitsu
| Category:
Air Conditioner
| Size: 12 MB
Table of Contents
General Information
3
Outdoor Unit
13
Installation Space Requirement
18
Outdoor Unit
49
Refrigerant System Diagrams
53
Troubleshooting
69
Table of Contents
71
Error Code
73
E: 11. Serial Communication Error (Serial Reverse Transfer Error) (Outdoor Unit)
77
E: 11. Serial Communication Error (Serial Forward Transfer Error) (Indoor Unit)
79
E: 12. →Ired Remote Controller Communication Error (Indoor Unit)
81
E: 15. Automatic Air Flow Adjustment Error (Indoor Unit)
82
E: 22. Indoor Unit Capacity Error (Indoor Unit)
83
E: 23. Combination Error (Outdoor Unit)
84
E: 32. Indoor Unit Main PCB Error (Indoor Unit)
85
E: 33. Indoor Unit Motor Electricity Consumption Detection Error (Indoor Unit)
86
E: 35. MANUAL AUTO Button Error (Indoor Unit)
87
E: 39. Indoor Unit Power Supply Error for Fan Motor (Indoor Unit)
88
E: 41. Room Temperature Sensor Error (Indoor Unit)
89
E: 42. Indoor Unit Heat Exchanger Sensor Error (Indoor Unit)
90
E: 51. Indoor Unit Fan Motor Error (Indoor Unit)
91
E: 53. Drain Pump Error (Indoor Unit)
92
E: 62. Outdoor Unit Main PCB Error (Outdoor Unit)
93
E: 63. Inverter Error (Outdoor Unit)
94
E: 64. PFC Circuit Error (Outdoor Unit)
95
E: 65. Trip Terminal L Error (Outdoor Unit)
96
E: 71. Discharge Thermistor Error (Outdoor Unit)
97
E: 72. Compressor Thermistor Error (Outdoor Unit)
98
E: 73. Heat Exchanger (Middle/Outlet) Temperature Thermistor Error (Outdoor Unit)
99
E: 74. Outdoor Temperature Thermistor Error (Outdoor Unit)
100
E: 77. Heat Sink Thermistor Error (Outdoor Unit)
101
E: 84. Current Sensor Error (Outdoor Unit)
102
E: 86. High Pressure Switch Error (Outdoor Unit)
103
E: 94. Trip Detection (Outdoor Unit)
104
E: 95. Compressor Motor Control Error (Outdoor Unit)
105
E: 97. Outdoor Unit Fan Motor Error (Outdoor Unit)
106
E: 99. 4-Way Valve Error (Outdoor Unit)
107
No Operation (Power Is On)
118
No Cooling/No Heating
119
Abnormal Noise
121
Ater Leaking
122
Service Parts Information
123
Compressor
123
Inverter Compressor
124
Outdoor Unit Electronic Expansion Valve (EEV)
128
Indoor Unit Fan Motor
132
Outdoor Unit Fan Motor
133
4-Way Valve Coil (Solenoid Coil)/4-Way Valve
134
Thermistor Resistance Values
135
Indoor Unit
135
Outdoor Unit
136
Control and Functions
139
Rotation Number Control of Compressor
143
Cooling Operation
143
Heating Operation
145
Dry Operation
146
Rotation Number of Compressor at Normal Start-Up
147
Rotation Number of Compressor Limitation by Outdoor Temperature
150
Auto Changeover Operation
154
Operation Flow Chart
155
Fan Control
156
Indoor Fan Control
156
Fan Operation
156
Cooling Operation
156
Outdoor Fan Control
159
Fan Speed
159
Louver Control
164
Horizontal Louver Control
164
Swing Operation
164
Timer Operation Control
165
On/Off Timer
165
Program Timer
165
Ireless Remote Control
165
Sleep Timer
166
Ired Remote Control
167
Weekly Timer
168
Temperature Setback Timer
169
Defrost Operation Control
170
Defrost Operation in Heating Operation Stopped
171
Various Control
172
Auto Restart
172
C HEAT Operation
172
ECONOM↔ Operation
172
PO→ERFUL Operation
172
Fresh Air Control
173
Compressor Preheating
173
External Electrical Heater Control
174
Electronic Expansion Valve Control
174
Drain Pump Control
175
Overflow Control
176
Prevention to Restart for 3 Minutes (3 Minutes St)
177
4-Way Valve Control
177
Human Sensor for Energy Saving
177
Peak Cut Operation(for 30/36/45 Model)
177
Various Protections
178
Discharge Gas Temperature Over-Rise Prevention Control
178
Anti-Freezing Control (Cooling and Dry Mode)
178
Current Release Control
179
Indoor Unit Fan Motor over Temperature Protection
180
Compressor Temperature Protection
181
High Pressure Protection
181
Low Outdoor Temperature Protection
181
Operation
182
Function Settings
187
Function Settings by Using Remote Controller
187
Contents of Function Setting
187
Function Setting List
187
Ceiling Height
188
Auto Restart
189
Function Settings (30-45 Models)
192
Control PCB and Switch Buttons Location
192
Switch Buttons and the Functions
193
Local Setting Procedure
194
Peak Cut Mode
195
External Input and Output
196
External Input
196
Indoor Unit
196
External Input and Output PCB
197
Input Select
197
External Output
198
Combination of External Input and Output
199
Input Signal Type
200
Details of Function
201
Forced Thermostat off Function
204
Control Output Function
204
Error Status
205
Indoor Unit Fan Operation Status
205
External Heater Output
206
External Input and Output (30-45 Models)
207
External Input
207
Low Noise Mode
207
External Output
209
Error Status Output
209
Compressor Status Output
210
Fujitsu AIRSTAGE ABEG18KRTA Design & Technical Manual (114 pages)
Brand:
Fujitsu
| Category:
Air Conditioner
| Size: 7 MB
Table of Contents
Table of Contents
3
Part 1. INDOOR UNIT
7
Specifications
8
Dimensions
14
Models: ABEG18KRTA and ABEG22KRTA
14
Models: ABEG24KRTA and ABEG30KRTA
15
Models: ABEG36KRTA and ABEG45KRTA
16
Installation Space Requirement
17
Wiring Diagrams
18
Models: ABEG18KRTA, ABEG22KRTA, ABEG24KRTA, and ABEG30KRTA
18
Models: ABEG36KRTA and ABEG45KRTA
19
Capacity Table
20
Cooling Capacity
20
Heating Capacity
22
Fan Performance
24
Air Velocity and Temperature Distributions
24
Airflow
30
Fresh Air Characteristics
36
Installation
38
Operation Noise (Sound Pressure)
39
Noise Level Curve
39
Sound Level Check Point
42
Safety Devices
43
External Input and Output
44
External Input
44
Indoor Unit
44
External Input and Output PCB
45
Input Select
45
External Output
46
Combination of External Input and Output
47
Input Signal Type
48
Details of Function
49
Forced Thermostat off Function
52
Control Output Function
52
Error Status
53
Indoor Unit Fan Operation Status
53
External Heater Output
54
Group Connection
55
Function Settings
56
10-1.Function Settings by Using Remote Controller
56
Contents of Function Setting
56
Function Setting List
56
Ceiling Height
57
Auto Restart
58
Accessories
61
11-1.Models: ABEG18KRTA and ABEG22KRTA
61
11-2.Models: ABEG24KRTA, ABEG30KRTA, ABEG36KRTA, and ABEG45KRTA
62
Optional Parts
63
12-1.Controllers
63
12-2.Others
64
Part 2. OUTDOOR UNIT
67
Specifications
68
Dimensions
71
Models: AOEG18KBTB and AOEG22KBTB
71
Model: AOEG24KBTB
72
Models: AOEG30KBTB and AOEG36KBTB
73
Model: AOEG45KBTB
74
Installation Space
75
Models: AOEG18KBTB, AOEG22KBTB, and AOEG24KBTB
75
Space Requirement
75
Single Outdoor Unit Installation
75
Multiple Outdoor Unit Installation
76
Outdoor Units Installation in Multi-Row
77
Models: AOEG30KBTB, AOEG36KBTB, and AOEG45KBTB
78
Outdoor Unit Installation in Multi-Row
80
Refrigerant Circuit
81
Model: AOEG18KBTB
81
Model: AOEG22KBTB
82
Model: AOEG24KBTB
83
Model: AOEG30KBTB
84
Models: AOEG36KBTB and AOEG45KBTB
85
Wiring Diagrams
86
Model: AOEG18KBTB
86
Models: AOEG22KBTB and AOEG24KBTB
86
Model: AOEG30KBTB
87
Model: AOEG36KBTB
87
Model: AOEG45KBTB
88
Capacity Compensation Rate for Pipe Length and Height Difference
89
Model: AOEG18KBTB
89
Model: AOEG22KBTB
90
Model: AOEG24KBTB
91
Model: AOEG30KBTB
92
Model: AOEG36KBTB
93
Model: AOEG45KBTB
94
Additional Charge Calculation
95
Model: AOEG18KBTB
95
Refrigerant Charge
95
Models: AOEG22KBTB and AOEG24KBTB
95
Models: AOEG30KBTB and AOEG36KBTB
95
Model: AOEG45KBTB
95
Airflow
96
Model: AOEG18KBTB
96
Model: AOEG22KBTB
96
Model: AOEG24KBTB
96
Models: AOEG30KBTB and AOEG36KBTB
97
Model: AOEG45KBTB
97
Operation Noise (Sound Pressure)
98
Noise Level Curve
98
Sound Level Check Point
101
Electrical Characteristics
102
Safety Devices
103
External Input and Output
105
12-1.External Input
105
Low Noise Mode
105
Peak Cut Mode
106
Error Status Output
107
12-2.External Output
107
Compressor Status Output
108
Function Settings
109
13-1.Control PCB and Switch Buttons Location
109
Switch Buttons and the Functions
110
13-2.Local Setting Procedure
111
Accessories
113
14-1.Models: AOEG18KBTB, AOEG22KBTB, and AOEG24KBTB
113
14-2.Models: AOEG30KBTB, AOEG36KBTB, and AOEG45KBTB
113
Optional Parts
114
Advertisement
Fujitsu AIRSTAGE ABEG18KRTA Design & Technical Manual (113 pages)
Ceiling type, REFRIGERANT R32 INVERTER, INDOOR/OUTDOOR
Brand:
Fujitsu
| Category:
Air Conditioner
| Size: 7 MB
Table of Contents
Table of Contents
3
Part 1. INDOOR UNIT
7
Specifications
8
Dimensions
14
Models: ABEG18KRTA and ABEG22KRTA
14
Models: ABEG24KRTA and ABEG30KRTA
15
Models: ABEG36KRTA and ABEG45KRTA
16
Installation Space Requirement
17
Wiring Diagrams
18
Models: ABEG18KRTA, ABEG22KRTA, ABEG24KRTA, and ABEG30KRTA
18
Models: ABEG36KRTA and ABEG45KRTA
19
Capacity Table
20
Cooling Capacity
20
Heating Capacity
22
Fan Performance
24
Air Velocity and Temperature Distributions
24
Airflow
30
Fresh Air Characteristics
36
Installation
38
Operation Noise (Sound Pressure)
39
Noise Level Curve
39
Sound Level Check Point
42
Safety Devices
43
External Input and Output
44
External Input
44
Indoor Unit
44
External Input and Output PCB
45
Input Select
45
External Output
46
Combination of External Input and Output
47
Input Signal Type
48
Details of Function
49
Forced Thermostat off Function
52
Control Output Function
52
Error Status
53
Indoor Unit Fan Operation Status
53
External Heater Output
54
Group Connection
55
Function Settings
56
10-1.Function Settings by Using Remote Controller
56
Contents of Function Setting
56
Function Setting List
56
Accessories
61
11-1.Models: ABEG18KRTA and ABEG22KRTA
61
11-2.Models: ABEG24KRTA, ABEG30KRTA, ABEG36KRTA, and ABEG45KRTA
62
Optional Parts
63
12-1.Controllers
63
12-2.Others
64
Part 2. OUTDOOR UNIT
67
Specifications
68
Dimensions
70
Model: AOEG18KATA
70
Models: AOEG22KATA and AOEG24KATA
71
Models: AOEG30KATA and AOEG36KATA
72
Model: AOEG45KATA
73
Installation Space
74
Models: AOEG18KATA, AOEG22KATA, and AOEG24KATA
74
Space Requirement
74
Single Outdoor Unit Installation
74
Multiple Outdoor Unit Installation
75
Outdoor Units Installation in Multi-Row
76
Models: AOEG30KATA, AOEG36KATA, and AOEG45KATA
77
Outdoor Unit Installation in Multi-Row
79
Refrigerant Circuit
80
Model: AOEG18KATA
80
Model: AOEG22KATA
81
Model: AOEG24KATA
82
Models: AOEG30KATA, AOEG36KATA, and AOEG45KATA
83
Wiring Diagrams
84
Model: AOEG18KATA
84
Model: AOEG22KATA
85
Model: AOEG24KATA
85
Models: AOEG30KATA and AOEG36KATA
86
Model: AOEG45KATA
87
Capacity Compensation Rate for Pipe Length and Height Difference
88
Model: AOEG18KATA
88
Model: AOEG22KATA
89
Model: AOEG24KATA
90
Model: AOEG30KATA
91
Model: AOEG36KATA
92
Model: AOEG45KATA
93
Additional Charge Calculation
94
Model: AOEG18KATA
94
Model: AOEG22KATA
94
Model: AOEG24KATA
94
Models: AOEG30KATA and AOEG36KATA
94
Model: AOEG45KATA
94
Airflow
95
Model: AOEG18KATA
95
Model: AOEG22KATA
95
Model: AOEG24KATA
95
Models: AOEG30KATA and AOEG36KATA
96
Model: AOEG45KATA
96
Operation Noise (Sound Pressure)
97
Noise Level Curve
97
Sound Level Check Point
100
Electrical Characteristics
101
Safety Devices
102
External Input and Output (30-45 Models)
103
12-1.External Input
103
Low Noise Mode
103
Peak Cut Mode
104
Error Status Output
105
12-2.External Output
105
Compressor Status Output
106
Function Settings (30-45 Models)
107
13-1.Control PCB and Switch Buttons Location
107
Switch Buttons and the Functions
108
13-2.Local Setting Procedure
109
Accessories
111
14-1.Models: AOEG18KATA, AOEG22KATA, and AOEG24KATA
111
14-2.Models: AOEG30KATA, AOEG36KATA, and AOEG45KATA
112
Optional Parts
113
Advertisement
Related Products
Fujitsu AIRSTAGE ABEG18-22KRTA
Fujitsu AIRSTAGE ABEG22KRTA
Fujitsu AIRSTAGE ABEG24KRTA
Fujitsu AIRSTAGE ABEG30KRTA
Fujitsu AIRSTAGE ABEG36KRTA
Fujitsu AIRSTAGE ABEG45KRTA
Fujitsu AIRSTAGE ABEG54KRTA
Fujitsu ABY45TL MA
Fujitsu ABYG36LRTE
Fujitsu AIRSTAGE AB A18L Series
Fujitsu Categories
Air Conditioner
Laptop
Server
Scanner
Storage
More Fujitsu Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL