Sign In
Upload
Manuals
Brands
FDP Manuals
Control Panel
EX-CP4L
FDP EX-CP4L Manuals
Manuals and User Guides for FDP EX-CP4L. We have
1
FDP EX-CP4L manual available for free PDF download: Installer Manual
FDP EX-CP4L Installer Manual (91 pages)
FIRE CONTROL PANEL
Brand:
FDP
| Category:
Control Panel
| Size: 2 MB
Table of Contents
Table of Contents
2
Part 1 Details
6
General Characteristics
6
Point Addressing and Acquisition
8
Part 2 Control Panel Installation
9
Safety Requirements
9
Connecting the Control Panel to the Main Power Line 230Vca
9
Fuses
9
Fixing the Container
10
Cable Arrangement
10
Observation
10
Assembly
11
Connection
11
The Circuits of the Detection
12
Fire Alarm Siren Output
13
Output for Alarm Siren Fault
14
Outputs of Auxiliary Relays no Supervised
15
Open Collector Outputs
15
Auxiliary Output 24 VDC
15
Serial Ports
15
Connection to the Power Supply
16
Battery Connections
16
Loop Section
16
Location of Ground Shunt in the Control Panel
16
Maintenance
17
Daily Control
17
Weekly Control
17
Four-Monthly Control
17
Yearly Control
17
Cleaning the Smoke Sensor
17
Part 3 Preliminary Remarks for a Correct Installation
18
Line Cable Test Procedure before Loop Connection
18
Line Continuity
18
Shielded
18
Isolation between Positive and Negative of Loop
18
Isolation between SHI / -LOOP and SHI / +LOOP
18
Check of SHI Short Circuits at Power Supply Line
19
Part 4 about Programming
20
Controls and Information
20
Control Panel Controls
20
Led Indicators of the Control Panel
21
How to Select an Item from the Menu of the Control Panel
22
Password Management
23
Access Levels
23
Levels for Users and Installers
23
Out of Service, Fault, Alarm Messages
24
General
24
Silence
24
View Messages
24
Visualizing the Event
26
Active Outputs
27
Alarm Reset
27
Visualization of Events
27
Main Menu
27
Event Menu
27
Part 5 First Configuration of Control Panel
28
Part 6 Loop Programming
31
Loop Starting
31
Main Menu
31
Loop Menu
31
Loop Start/Restore (Loop Selection)
31
Loop Start/Restore Procedure
32
Information
32
Confirmation
32
Loop out of Service
32
Part 7 Point Programming
33
Point Insertion
33
Procedure for the Acquisition of a Point
33
Main Menu
34
Point Menu
34
Address Assignation
34
Type of Point Acquisition
34
Loop Selection
35
Point Address Selection
35
Detectors Check Values
35
Points Acquisition Modes: Installer, Activation and Pre-Set Address
35
Points Acquisition in Mode: Serial Number
36
Point Information
37
Main Menu
37
Point Menu
37
Loop Selection
37
Point Address Selection
38
Point Setting
38
Points Removal
40
Main Menu
40
Point Menu
40
Points Removal (Options)
41
Loop Selection
41
Point Address Selection
41
Zone Address Selection
41
Part 8 Zone Programming
42
Details
42
Zone Creation
42
Zone Setting
42
Main Menu
42
Zone Menu
42
Loop Selection
43
Zone Address Selection
43
Zone Setting
43
Part 9 Outputs Programming
45
Details
45
Main Menu
45
Output Menu
45
Output Selection
45
Output Setting
46
Control Panel Output
48
Output Description
48
24Vdc Output
48
Siren Output
48
Fault Output
49
Relay Outputs
49
Open Collector Outputs
49
Loop Output
50
Relay Output
50
Open Collector Output
50
Logics of Activation
50
Logic States
51
Logic of Activation
51
Part 10 Setting Menu
53
Details
53
Supervised / Unsupervised
53
Evacuation
54
Fire Restoration
54
Date / Time
55
Prompt
55
Password
56
Retrieval of Forgotten Password
56
Loop Activation
57
Restoring Default Settings
57
Part 11 Diagnostics Menu
58
Details
58
Software Version
58
Smoke Detectors Verification
58
Lamp Test
59
Autoreset
59
Chronological Reset
60
Part 12 Connection Menu
61
Details
61
External Ps2 Keypad
61
Auxiliary Power Source
62
Serial Outputs (Rs232-Rs485-Lan)
62
Local Net Setting
62
RS232 Connection
62
RS485 Connection
63
LAN Connection
63
Part 13 Evacuation
65
Details
65
Evacuation Menu
66
Evacuation Start
66
Evacuation" and "Extinguish" Outputs
67
Part 14 Repeater Panel
68
Details
68
Rs232 Connection
68
Part 15 Points Description and Utilization
69
Detectors
69
Detector Addressing
69
Manual Zero Setting of the Address
69
Smoke Detector
70
Heat Detector
71
Multicriterion Detector
72
Electrical Schemes
73
Resettable Button
73
Input and Output Description
73
Button Addressing
73
Manual Zero Setting of the Address
73
Point Setting
73
Electrical Scheme
74
Input/Output Module
74
Input and Output Description
75
Module Addressing
75
Manual Zero Setting of the Address
75
Point Setting
75
Electrical Schemes
76
Connection Lay-Out of Smoke and Gas Linear Detectors
76
Programmed I/O Module for Bathroom Alarm
77
Part 16 Generic Electrical Schemes
78
Connection Beetwen Control Panels and Pc (Rs485)
79
Control Panel Connection on Lan
79
Siren and Magnet Connection with Control Panel
80
Some Connection Points
81
Part 17 Quick Programming Procedures
82
Details
82
Firs Control Panel Turn on
82
Installation Loop
82
Point Activation
83
Input Programming
84
Output Programming
84
Setting an Output Delay
84
Reset Mode of Fire Alarm
85
Reset of Control Panel for the Default Set up
86
Part 18 How to Solve the Problems
88
Part 19 Technical Characteristics
90
Advertisement
Advertisement
Related Products
FDP EX-CPL
FDP EMS-HH
FDP CFN
FDP Categories
Transceiver
Control Panel
More FDP Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL