Eurtotherm 2204e Manuals
Manuals and User Guides for Eurtotherm 2204e. We have
1
Eurtotherm 2204e manual available for free PDF download: Engineering Handbook
Eurtotherm 2204e Engineering Handbook (90 pages)
2200e Series
Brand:
Eurtotherm
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Installation
7
Instrument Layouts
7
Outline Dimensions
8
Recommended Minimum Spacing of Controllers
8
Introduction
9
Controller Labels
9
Mechanical Installation
9
Unplugging and Plugging-In the Controller
9
Wiring
10
Wire Sizes
11
Sensor Input Connections
12
Outputs 1 and 2 Connections
12
PDS Modes
13
Snubbers
13
Typical Single Loop Wiring Diagram
13
Logic Drive Fan out
14
EIA232/485/422 Communication Connections
14
Wiring of EIA-485 Serial Communication Links
15
Devicenet® Wiring to Series 2200E Controllers
16
Devicenet Terminal Functions
16
Wiring Interconnections for Devicenet Communications
16
2 Operation
17
Front Panel Layout
17
Getting Started
19
To View the Process Value and Setpoint
19
To Adjust the Setpoint
19
To View the Display Units
19
Use of the "SCROLL" Button
20
Use of the 'PAGE' Button
20
Parameter Lists
21
Manual or Automatic Control
22
To Select Auto/Manual Operation
22
To Select Setpoint 1 Orsetpoint 2
23
Ramp Dwell Function
23
To Set up a Ramp/Time Program
24
To Run the Program
24
Power Failure During Program Run
24
Location of Parameters - Block Diagram
25
Navigation Diagram
26
Parameter Tables
27
HOME Display
27
Alarm List
27
Autotune List
28
PID List
28
Setpoint List
28
Input List
29
On/Off List
29
Output List
29
Communications List
30
Access List
30
Alarms
31
Types of Alarm Used in the 2200
31
Alarm Relay Output
32
Setting Alarm Levels
32
Alarm Indication and Acknowledgement
33
Diagnostic Alarms
34
3 Access Levels
35
The Different Access Levels
35
Selecting an Access Level
35
Access List Header
35
Password Entry
35
Level Selection
36
Configuration Password
36
Configuration Level
36
To Return to Operator Level
36
Edit Level
37
To Set Operator Access to a Parameter
37
To Hide or Reveal a Complete List
37
To Promote a Parameter
37
4 Tuning
39
What Is Tuning
39
Automatic Tuning
39
Heating and Cooling Output Cycle Times
39
How to Tune
40
Typical Automatic Tuning Cycle
40
Calculation of the Cutback Values
40
Manual Tuning
41
Setting the Cutback Values
41
Integrating Action and Manual Reset
42
Automatic Droop Compensation (Adc)
42
5 Configuration
43
To Select Configuration Level
43
To Select a Configuration Parameter
44
To Leave Configuration Level
44
Steps Involved in Configuring a Controller
44
Navigation Diagram (PART A)
45
Configuration Parameter Tables
47
Instrument Configuration
47
Input Configuration
48
Calibration Configuration
48
Alarm Configuration
49
Logic Inputs Configuration - 2208E and 2408E Only
49
AA Alarm Relay Configuration - 2208E and 2408E Only
50
Digital Communications Configuration
50
Output 1 Configuration
51
Output 2 Configuration
52
Output 3 Configuration
52
Output 4 Configuration
52
Password Configuration
52
Exit Configuration
52
Configuration of Digital Communications
53
To Configure the Function, and Baud Rate
53
To Set Instrument Address
53
Devicenet
54
The EDS File
54
ODVA Compliance
54
6 User Calibration
55
What Is the Purpose of User Calibration
55
User Calibration Enable
55
The User Calibration Configuration List
55
Single Point Calibration
56
Two Point Calibration
57
Calibration Points and Calibration Offsets
57
7 Alarm Configuration
59
Definition of Alarms and Events
59
Types of Alarms
59
Digital Output Functions
60
Step1 - to Configure the Four 'Soft' Alarms
61
Step 2 - to Attach an Alarm to a Physical Output
62
Step 3 - to Group Alarms on a Single Output
63
Step 4 - to Remove Alarms from an Output
63
8 Motorised Valve Control
65
Parameters for Motorised Valve Control
65
Commissioning the Motorised Valve Controller
65
Adjusting the Minimum On-Time 'Ont.h
65
Motorised Valve Applications
66
Auto Tuning
66
Valve Positioner Set-Up Table
66
9 Load Current Monitoring and Diagnostics
67
Load Current Monitoring and Diagnostics
68
Example Wiring Diagram (for Mode 1 & 2 Operation)
68
Example Wiring Diagram (for Mode 5 Operation)
69
Operation
70
To Read Load Current (Modes 2 and 5 Only)
70
To Display Load Current Continuously in the Lower Readout (Modes 2 and 5 Only)
70
Display Modes
70
How Heater Alarms Are Displayed
71
To Set the Alarm Trip Levels
71
Relay Outputs
72
To Configure PDS Load Current Diagnostics
72
To Configure the Logic Module for PDS Modes 1 or 2
72
To Configure Logic Input 1 for PDS (Mode 5 Only)
73
To Configure Low and High Current Trip Alarms
73
To Attach Soft Alarms to a Relay Output
74
The Scaling Factor
75
To Adjust the Scaling Factor
75
10 Retransmission
77
What Is Retransmission
77
To Configure Retransmission
77
To Scale Retransmitted Output Signals
78
To Range Retransmitted Output OP
78
To Range Retransmitted Setpoint SP or Process Variable PV
78
To Range Retransmitted Error Err
78
11 Understanding the Order Code
79
12 SAFETY and EMC Information
81
Technical Specification
83
13 Supplement 2208E Instruments
87
14 Index
89
Advertisement
Advertisement
Related Products
Eurtotherm 2216e
Eurtotherm 2208e
Eurtotherm Categories
Controller
More Eurtotherm Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL