Sign In
Upload
Manuals
Brands
Entek IRD Manuals
Data Loggers
dataPAC 1250
Entek IRD dataPAC 1250 Manuals
Manuals and User Guides for Entek IRD dataPAC 1250. We have
1
Entek IRD dataPAC 1250 manual available for free PDF download: User Manual
Entek IRD dataPAC 1250 User Manual (254 pages)
Brand:
Entek IRD
| Category:
Data Loggers
| Size: 4 MB
Table of Contents
Table of Contents
9
Introduction
15
Chapter 1
16
Overview of the Datapac
16
Using the Manual
16
Using the Online Help Systems
18
Datapac Online Help
18
Contacting Customer Support
18
The Datapac
19
Chapter 2
20
Overview of the Datapac
20
Parts of the Datapac
20
Data Collector Diagram and Key Definitions
21
Data Collector Hardware Connectors
23
Datapac Battery Pack and Charger
24
Checking Battery Life
24
Charging the Battery
25
Datapac Windows and Screens
25
Using Selection Windows
25
Using Edit Windows
27
Using Help Windows
28
Basic Datapac Operations
30
Powering down the Data Collector
30
Powering up the Data Collector
30
Changing the Display Contrast
31
Displaying the Operating System Version Number
31
Restarting the Data Collector
31
Loading the Operating System with the Datapac Utility Program
32
Using Other Features of the Datapac Utility Program
34
Using the Datapac Setup Program
38
Setting up Data Collection Options
40
Setting up Instrument Options
42
Setting up FFT Display Options
43
Setting up Time Waveform Options
45
Setting the Data Collector Date and Time
48
Installing and Defining Datapac Transducers
50
Using Memory Cards
55
Inserting and Removing a Memory Card
55
Memory Card Battery
56
Write-Protecting a Memory Card
56
Initializing the Data Collector Memory Cards
57
Memory Card Storage Capacity
59
Using the Memory Card Manager
60
Changing Font Size on the Display
61
Deleting Items
61
Displaying Screen Images
61
Sorting Database Information
61
Using Security Keys
61
Adding a Feature with a Security Key
62
Disabling or Transferring a Function
62
Collecting and Reviewing Data
65
Chapter 3
66
Overview of Collecting Data
66
Preparing for Data Collection
66
Connecting the Transducer to the Data Collector
67
Selecting the Data Collection Options
67
Ranging Measurements Manually
68
Collecting Programmed Data
68
Starting a Route for Programmed Data Collection
68
Installing the Transducer for Programmed Data Collection
70
Setting up the Program Parameters
70
Running the Program
72
Reviewing Overall Data and Alarms Reports
76
Overview of the Review Data Window
76
Reviewing Overall, Speed, & Alarms
80
Reviewing Bands and Alarms
81
Reviewing Spectra Data
83
Using the Cursors with a Spectrum
83
Using Dual Cursors with a Spectrum
84
Using Sideband Cursors with a Spectrum
86
Using Harmonic Cursors with a Spectrum
87
Using Diagnostic Frequency Cursors with a Spectrum
88
Changing the Spectrum Display
89
Reviewing Waterfall Spectra Data
93
Changing the Viewing Angle of a Waterfall Display
94
Reviewing Specific Spectral Data Sets in Waterfall Mode
94
Reviewing Time Waveform Data
96
Using the Cursors on a Time Waveform Display
97
Using Dual Cursors with Time Waveform
98
Using Cyclic Cursors with Time Waveform
99
Capturing and Printing Datapac Screens
99
Printing Datapac Screens Directly
100
Transferring Images to Your Computer
101
Viewing Captured Screens on Your Computer
103
Commands Available While Viewing Images
105
Printing Reports and Plots Using Host Software
105
Off Route Analysis with the Datapac
107
Chapter 4
108
Collecting off Route or Analysis Data
108
Collecting off Route Data with the Datapac 1250
108
Collecting off Route or Analysis Data with the Datapac 1500
108
Ranging Measurements Manually
109
Setting up and Collecting off Route Overall Measurements
110
Setting up off Route Overall Measurements
110
Collecting an off Route Overall Measurement
112
Collecting Dynamic Non-Vibration Measurements
113
Collecting off Route Overall Sound Measurements
113
Setting up and Collecting off Route Spectrum Measurements
114
Setting up off Route Spectrum Measurements
114
Collecting an off Route Spectrum Measurement
119
Driving a Strobe While Collecting an off Route Spectrum
119
Stopping, Saving, and Viewing an off Route Spectrum Measurement
121
Setting up and Collecting off Route Orders Measurements
123
Background Information about Orders Based and Orders Track
123
Setting up Orders Based Measurements
126
Setting up an off Route Orders Track Spectrum Measurement
128
Setting up and Collecting off Route Time Waveform Measurements
130
Setting up off Route Time Waveform Measurements
130
Collecting off Route Time Waveform Measurements
135
Setting up off Route Gse Time Waveform Measurements
135
Setting up and Collecting off Route True Zoom Measurements
136
Setting up off Route True Zoom Measurements
136
Collecting off Route True Zoom Measurements
140
Setting up and Collecting off Route Phase/Magnitude/Speed
140
Setting up off Route Phase/Magnitude/Speed Measurements
140
Collecting off Route Phase/Magnitude/Speed Measurements
143
Using a Strobe to Collect Phase/Magnitude/Speed Measurements
144
Setting up Start-Up/Coast-Down Measurements
145
Collecting and Analyzing Data Using Waterfall/Fft
153
Collecting and Analyzing Data Using Bode/Nyquist
155
Methods for Measuring Machine Speed
157
Phase-Magnitude-Speed
157
Balancing Application
158
Machine Speed Softkey
158
Orders Based/Orders Track
158
Strobe Light
158
Using an Internal Trigger Source to Collect Data
159
Setting up and Collecting an Internally Triggered Spectrum or Time Waveform
159
Performing a Bump Test
160
Balancing Measurements
163
Chapter 5
164
Overview of Balancing Measurements
164
Setting up the Balancing Parameters
165
One Plane Balancing with a Strobe Light
167
Using the Strobe Db
167
Measuring Speed with a Strobe
168
Taking the Initial Vibration Measurement
169
Adding the Trial Weight and Taking a Measurement
173
Adding the Correction Weight and Taking a Residual Measurement
175
Two Plane Balancing with a Strobe Light
177
Taking the Initial Vibration Measurement
177
Adding the Trial Weight and Taking a Measurement in Plane 1
180
Adding the Trial Weight and Taking a Measurement in Plane 2
183
Adding the Correction Weights and Taking a Residual Measurement
184
One Plane Balancing with a Reference Trigger
186
Setting up the Entach Digital Laser Tachometer
186
Taking the Initial Vibration Measurement
187
Adding the Trial Weight and Taking a Measurement
189
Adding the Correction Weight and Taking a Residual Measurement
191
Two Plane Balancing with a Reference Trigger
192
Taking the Initial Vibration Measurement
192
Adding the Trial Weight and Taking a Measurement in Plane 1
195
Adding the Trial Weight and Taking a Measurement in Plane 2
197
Adding the Correction Weights and Taking a Residual Measurement
199
Unloading Balancing Runs Using a Modem
201
Setting up Remote Transfer on the Host Computer
202
Setting up Remote Transfer on the Datapac
203
Unloading Balancing Files to the Host Computer
206
Collecting Phase Measurements for Analysis
209
Frequency Response Function (FRF)
211
Chapter 6
212
Overview of the Datapac 1500 FRF Module
212
Hardware Required by the FRF Module
212
Force Hammer
213
Accelerometer
218
Understanding the Concepts Behind the FRF Module
218
What Is Stiffness
218
FRF Module Requires Linear Structure Response
219
Static Vs. Dynamic Stiffness
219
Six Frequency Response Functions
220
Connecting the Force Hammer
221
Setting up FRF Measurements
221
Signal Processing Features of the FRF Module
221
Connecting the Accelerometer
222
Setting up the Force Channel and Response Channel
223
Force Channel Setup - Text Mode
225
Response Channel Setup - Text Mode
227
Setting up the FRF Measurement
227
Collecting and Analyzing FRF Data
228
Reviewing the FRF Data
230
Structural Analysis Using the FRF
234
Appendix
239
Frequently Asked Questions and Answers
239
Collecting Data with the Datapac
239
General Datapac Questions
239
Glossary
241
Index
245
Advertisement
Advertisement
Related Products
Entek IRD dataPAC 1500
Entek IRD Categories
Monitor
Protection Device
Gateway
Data Loggers
More Entek IRD Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL