Sign In
Upload
Manuals
Brands
Emerson Manuals
UPS
Series 610
Emerson Series 610 Manuals
Manuals and User Guides for Emerson Series 610. We have
1
Emerson Series 610 manual available for free PDF download: Installation Manual
Emerson Series 610 Installation Manual (112 pages)
500-750kVA, 60Hz, Three Phase Multi-Module
Brand:
Emerson
| Category:
UPS
| Size: 3.08 MB
Table of Contents
Battery Cabinet Precautions
2
Contacting Liebert for Support
2
Table of Contents
3
Important Safety Instructions
7
Save These Instructions
7
1 Installation Considerations
9
Figure 1 Multi-Module 500 to 750Kva UPS
10
Figure 2 UPS Multi-Module Unit Block Diagram
10
Types of System Control Cabinets
11
Figure 3 System Control Cabinets
11
2 Unloading and Handling
12
3 Inspections
13
External Inspections
13
Internal Inspections and Shipping Material Removal
13
4 Equipment Location
14
5 Battery Installation
15
Battery Safety Precautions
15
Battery Safety Precautions in French Per CSA Requirements
16
Battery Cabinets
17
Open-Rack Batteries
18
6 Configuring Your Neutral and Ground Connections
19
Preferred Grounding Configuration, Wye-Connected Service
20
Figure 4 Preferred Grounding Configuration, Wye-Connected Service
20
Alternate Grounding Configuration, Wye-Connected Service
21
Figure 5 Alternate Grounding Configuration, Wye-Connected Service
21
Preferred Grounding Configuration with Isolated Bypass
22
Figure 6 Preferred Grounding Configuration with Isolated Bypass
22
Alternate Grounding Configuration, Non-Isolated
23
Figure 7 Alternate Grounding Configuration, Non-Isolated
23
Grounding Configuration, Corner-Grounded Delta or Impedance-Grounded Wye
24
Figure 8 Preferred Grounding Configuration, Corner-Grounded Delta or Impedance-Grounded Wye
24
Figure 9 Preferred Grounding Configuration, Impedance-Grounded Wye
25
Preferred Grounding Configuration, Battery Systems
26
Figure 10 Preferred Grounding Configuration, Battery Systems
26
7 Wiring Considerations
27
Power Wiring
28
Figure 11 Power Single Line Diagrams, Multi-Module Configurations
29
Output
29
Control Wiring
30
Table 1 Abbreviations for Circuit Breakers
30
Battery Wiring
31
8 Wiring Connections
32
Specific Connections
32
9 Wiring Inspection
34
Table 2 Power Wiring Terminals, Factory Supplied
34
Table 3 Torque Specifications
34
Table 4 Field-Supplied Lugs
35
Table 5 Table 310-16, National Electrical Code (Reprint)
36
10 Installation Drawings
37
Figure 12 One-Line Diagram, Two-Module Parallel System with Two-Breaker Maintenance Bypass
37
Figure 13 One-Line Diagram, Four-Module Parallel System with Three-Breaker Maintenance Bypass
38
Figure 14 Outline Drawing, 500Kva Multi-Module UPS, 6-Pulse Rectifier, 480V Input, 480/277V
39
Figure 15 Terminal Details, 500Kva Multi-Module UPS, 6-Pulse Rectifier, 480V Input, 480/277V
40
Figure 16 Outline Drawing, 500Kva Multi-Module UPS, 6-Pulse Rectifier, 600V Input, 600/346V
41
Figure 17 Terminal Details, 500Kva Multi-Module UPS, 6-Pulse Rectifier, 600V Input, 600/346V
42
Figure 18 Outline Drawing, 500Kva Multi-Module UPS, 12-Pulse Rectifier
43
Figure 19 Terminal Details, 500Kva Multi-Module UPS, 12-Pulse Rectifier
44
Figure 20 Outline Drawing, 625-750Kva Multi-Module UPS, 6-Pulse Rectifier
45
Figure 21 Terminal Details, 625-750Kva Multi-Module UPS, 6-Pulse Rectifier
46
Figure 22 Outline Drawing, 625-750Kva Multi-Module UPS, 12-Pulse Rectifier
47
Figure 23 Terminal Details, 625-750Kva Multi-Module UPS, 12-Pulse Rectifier
48
Figure 24 Outline Drawing, 500Kva Multi-Module UPS, 12-Pulse Rectifier with Bottom Entry
49
Figure 25 Terminal Details, 500Kva Multi-Module UPS, 12-Pulse Rectifier with Bottom Entry
50
Figure 26 Outline Drawing, 625-750Kva Multi-Module UPS, 6-Pulse Rectifier with Bottom Entry
51
Figure 27 Terminal Details, 625-750Kva Multi-Module UPS, 6-Pulse Rectifier with Bottom Entry
52
Figure 28 Outline Drawing, 625-750Kva Multi-Module UPS, 12-Pulse Rectifier with Bottom Entry
53
Figure 29 Terminal Details, 625-750Kva Multi-Module UPS, 12-Pulse Rectifier with Bottom Entry
54
Figure 30 Terminal Details, 750Kva/675Kw Multi-Module UPS, 12-Pulse Rectifier with Bottom Entry
55
Figure 31 Base Mounting Patterns, 500Kva Module, 6-Pulse Rectifier
56
Figure 32 Base Mounting Patterns, 500Kva Module, 12-Pulse Rectifier
57
Figure 33 Base Mounting Patterns, 500Kva Module, 12-Pulse Rectifier with Bottom Entry Wireway
58
Figure 34 Base Mounting Patterns, 625-750Kva Module, 6-Pulse Rectifier
59
Figure 35 Base Mounting Patterns, 625-750Kva Module, 6-Pulse Rectifier with Bottom Entry Wireway
60
Figure 36 Base Mounting Patterns, 625-750Kva Module, 12-Pulse Rectifier
61
Figure 37 Base Mounting Patterns, 625-750Kva Module, 12-Pulse Rectifier with Bottom Entry Wireway
62
Figure 38 Shipping Split Detail, 500Kva, 12-Pulse Rectifier
63
Figure 39 Shipping Split Detail, 500Kva, 12-Pulse Rectifier with Bottom Entry Wireway
64
Figure 40 Shipping Split Detail, 625-750Kva, 6-Pulse Rectifier
65
Figure 41 Shipping Split Detail, 625-750Kva, 6-Pulse Rectifier with Bottom Entry Wireway
66
Figure 42 Shipping Split Detail, 625-750Kva, 12-Pulse Rectifier
67
Figure 43 Shipping Split Detail, 625-750Kva, 12-Pulse Rectifier with Bottom Entry Wireway
68
Figure 44 Battery Power Pack System
69
Figure 45 Battery Power Pack, Size a
70
Figure 46 Line-Up Detail, 300-500Kva Single- or Multi-Module System with Battery Cabinets
71
Figure 47 Outline Drawing, System Control Cabinet (SCCT), 200-1200A
72
Figure 48 Base Mounting Patterns, System Control Cabinet (SCCT), 200-1200A
73
Figure 49 Outline Drawing, System Control Cabinet (SCCT), 1600-2000A
74
Figure 50 Base Mounting Patterns, System Control Cabinet (SCCT), 1600-2000A
75
Figure 51 Outline Drawing, System Control Cabinet (SCCT), 2500-3000A
76
Figure 52 Base Mounting Patterns, System Control Cabinet (SCCT), 2500-3000A
77
Figure 53 Outline Drawing, System Control Cabinet (SCCT), 4000A
78
Figure 54 Base Mounting Patterns, System Control Cabinet (SCCT), 4000A
79
Figure 55 Control Connection Location Diagram, Multi-Module System, 300-500Kva
80
Figure 56 Control Connection Location Diagram, Multi-Module System, 625 & 750Kva
81
Figure 57 Control Connection Location Diagram, SCCT
82
Figure 58 Control Wiring, External Interconnect Diagram, Multi-Module System
83
Figure 59 Control Wire List, External Interconnections, Standard Wiring, Multi-Module System
84
Figure 60 Control Wire List, External Interconnections, Standard Wiring, Multi-Module System
85
System Control Cabinet, Part 1 of 3, Cable Groups #2 & #3
85
Figure 61 Control Wire List, External Interconnections, Standard Wiring, Multi-Module System
86
System Control Cabinet, Part 2 of 3, Cable Groups #5 & #6
86
Figure 62 Control Wire List, External Interconnections, Standard Wiring, Multi-Module System
87
System Control Cabinet, Part 3 of 3, Cable Group #8
87
Figure 63 Control Wire List, External Interconnections, Multi-Module System, Remote Status Panel
88
Option, Cable Group #4
88
Duty Static Switch), Customer Alarm Interface Option, Cable Group #9
89
Figure 65 Control Wire List, External Interconnections, Multi-Module System, Alarm Status Contacts
90
Figure 66 Control Wire List, External Interconnections, Multi-Module System, Battery Temperature
91
Figure 67 Control Wire List, External Interconnections, Multi-Module System, Maintenance Bypass
92
Interlock Option, Cable Group #7
92
Figure 68 Control Wire List, External Interconnections, Multi-Module System, SNMP Interface Option
93
Cable Groups #20 & #21
94
Figure 69 Control Wire List, External Interconnections, Multi-Module System, Module 1/SCC
94
Figure 70 Control Wire List, External Interconnections, Multi-Module System, Module 2/SCC
95
Figure 71 Control Wire List, External Interconnections, Multi-Module System, Module 3/SCC
96
Figure 72 Control Wire List, External Interconnections, Multi-Module System, Module 4/SCC
97
Figure 73 Control Wire List, External Interconnections, Multi-Module System, Module 5/SCC
98
Cable Groups #20 & #21
99
Figure 74 Control Wire List, External Interconnections, Multi-Module System, Module 6/SCC
99
Figure 75 Outline Drawing, Single-Breaker Module Battery Disconnect
100
Figure 76 Outline Drawing, Single-Breaker Module Battery Disconnect
101
Figure 77 Outline Drawing, Dual-Breaker Module Battery Disconnect, 600, 800, 1000, 1200A
102
Figure 78 Outline Drawing, Remote Status Panel, Surface Mount
103
Appendixa - Site Planning Data , Series 610, 500-750 Kva, Multi -Module Systems
105
Table 6 Site Planning Data-600V Input
106
Table 7 Site Planning Data-480V Input
107
Table 8 System Control Cabinet Data - SCCT
108
Advertisement
Advertisement
Related Products
Emerson 6 kVA
Emerson 6000RTL630
Emerson Liebert Npower 65-80 kVA
Emerson 614
Emerson Aventics 617 Series
Emerson Series 600T
Emerson 6513DE
Emerson Fisher 67CF
Emerson Fisher 67CFSR
Emerson Fisher 67DR
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL