Sign In
Upload
Manuals
Brands
Emerson Manuals
Measuring Instruments
Rosemount 54eC-01
Emerson Rosemount 54eC-01 Manuals
Manuals and User Guides for Emerson Rosemount 54eC-01. We have
1
Emerson Rosemount 54eC-01 manual available for free PDF download: Instruction Manual
Emerson Rosemount 54eC-01 Instruction Manual (116 pages)
Amperometric HART Analyzer/Controller
Brand:
Emerson
| Category:
Measuring Instruments
| Size: 23 MB
Table of Contents
Essential Instructions
3
Table of Contents
5
Specifications
8
Features and Applications
8
Specifications - General
9
Ordering Information
11
Installation
12
Unpacking and Inspection
12
Wall Mounting
13
Pipe Mounting
13
Pipe and Wall Mounting Dimensions
13
Panel Mounting
14
Panel Mounting Dimensions
14
Wiring
15
General
15
Power, Alarm, and Output Wiring
15
Power Input and Relay Output Wiring for Model 54Ea
16
Sensor Wiring
17
Wiring Label
17
Free Chlorine Sensor with Standard Cable and 399VP-09 Ph Sensor Without
18
Free Chlorine Sensor with Standard Cable and 399-14 Ph Sensor Having Internal Preamplifier
19
Free Chlorine Sensor with Optimum EMI/RFI Cable or Variopol Cable and 399-14 Ph Sensor Having Internal Preamplifier
20
Hx438 and Gx448 Sensors
22
Display and Operation
23
General Description
23
Display
23
Key Functions and Controls
23
Alarm Status
23
Configuration of Inputs and Outputs for Free Chlorine
23
Main Display Screen
23
Software Configuration
24
Program Settings List
24
Menu Tree for the 54Ea Controller
28
Changing Alarm Setpoints
31
Ranging the Outputs
32
Changing Output Setpoints (PID Only)
33
Testing Outputs and Alarms
34
Choosing Display Options
35
Security Caution
36
Changing Output Parameters
37
Changing Alarm Parameters
40
Low Alarm
42
High Alarm
42
Interval Timer
44
Configuring the Ph Measurement
45
Application Warning
47
Temperature Compensation and Temperature Units
48
Noise Reduction
49
Main Sensor Calibration Parameters
50
Barometric Pressure
51
Security
52
Controller Mode Priority
53
Controller Mode Priority Chart
53
Calibration - Temperature
54
Introduction
54
Temperature Calibration
55
Calibration - Dissolved Oxygen
56
Introduction
56
Sensor Current as a Function of Dissolved Oxygen Concentration
56
Zeroing the Sensor
57
Calibrating the Sensor in Air
58
Calibrating the Sensor against a Standard Instrument
60
Calibrating Barometric Pressure
61
Calibration - Free Chlorine
62
Introduction
62
Sensor Current as a Function of Free Chlorine Concentration
62
Zeroing the Sensor
63
Full Scale Calibration
64
Dual Slope Calibration
65
Calibration - Total Chlorine
67
Introduction
67
Sensor Current as a Function of Total Chlorine Concentration
67
Zeroing the Sensor
68
Full Scale Calibration
69
Dual Slope Calibration
70
Calibration - Monochloramine
72
Introduction
72
Sensor Current as a Function of Monochloramine Concentration
72
Zeroing the Sensor
73
Full Scale Calibration
74
Calibration - Ozone
75
Introduction
75
Sensor Current as a Function of Ozone Concentration
75
Zeroing the Sensor
76
Full Scale Calibration
77
CALIBRATION - Ph
78
Introduction
78
Calibration Slope and Offset
78
Automatic Two-Point Calibration
79
Manual Two-Point Calibration
81
Standardization (One-Point Calibration)
83
Ph Slope Adjustment
84
Calibration - Current Outputs
85
Introduction
85
Trimming the Outputs
85
Pid and Tpc Control
86
PID Control
86
The Process Reaction Curve
88
Time Proportional Control (TPC)
90
Time Proportional Control
90
Troubleshooting
91
Overview
91
Troubleshooting When a Fault Message Is Showing
91
Troubleshooting When no Fault Message Is Showing - Temperature
93
Troubleshooting When no Fault Message Is Showing - Oxygen
93
Troubleshooting When no Fault Message Is Showing - Free Chlorine
96
Troubleshooting When no Fault Message Is Showing - Total Chlorine
98
Troubleshooting When no Fault Message Is Showing - Monochloramine
99
Troubleshooting When no Fault Message Is Showing - Ozone
102
Troubleshooting When no Fault Message Is Showing - Ph
104
Troubleshooting Not Related to Measurement Problems
107
Simulating Inputs - Dissolved Oxygen
107
Simulate Dissolved Oxygen
107
Simulating Inputs - Other Amperometric Measurements
108
Simulate Chlorine and Ozone
108
Simulating Inputs - Ph
109
Simulate Ph
109
Simulating Temperature
110
Three-Wire RTD Configuration
110
Simulating RTD Inputs
110
Measuring Reference Voltage
111
Checking for a Poisoned Reference Electrode
111
Maintenance
112
Replacement Parts
112
Return of Materials
113
Non-Warranty Repair
113
Warranty
114
Advertisement
Advertisement
Related Products
Emerson Rosemount 54eA
Emerson Rosemount 5900
Emerson Rosemount 5900S Series
Emerson Rosemount 5408
Emerson 586505000
Emerson 586505500
Emerson Rosemount 56
Emerson 56WM WirelessHART SensEnable
Emerson ROSEMOUNT370XA
Emerson Rosemount 8750W
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL