eleXsys EEdS 3042 User Manual And Installation Manual (59 pages)
30 kVA Three-Phase EEdS
Brand:
eleXsys
| Category:
Power Inductor
| Size: 3 MB
Table of Contents
Table of Contents
2
Symbols
7
Product Information
8
Scope
8
Model
9
Tag Information
9
Figure 1: Device Nameplate Example
9
Features
10
Three-Phase or Single-Phase
10
DC Voltage Range
10
Frequency
10
Four Quadrant Operation
11
Phase Balancing
11
Battery Charging and Discharging
11
Power Conditioning
11
Harmonic Correction
11
Current or Voltage Source Inverter
11
Power Factor Correction
11
Power Flow Regulation
12
Uninterruptable Power Supply (UPS) - Future Development
12
Off Grid Operation - Future Development
12
Grid Voltage Regulation
12
Communication and Data Logging
13
Communication Interfaces
13
Communication Protocols
13
Data Logging
13
Eeds30 Specification
14
Table 1: Eeds30 Technical Specifications
15
Appearance
16
Figure 2:Elexsys Product Appearance
16
Installation Guide
17
Applicable Standards and Guides
17
Pre-Cautions
18
Potential Hazards or Injuries
18
Risks and Safety
18
Working with Batteries
19
Labelling of Electrical Apparatus
19
Categorized Installation Components
21
Electrical Connections
22
Eeds Architecture
22
Figure 3: an Illustration of Eeds30 Architecture
22
Electrical Connection Diagram
23
Figure 4: Electrical Connection Diagram between the Battery and Main AC Grid
23
Table 2: Minimum Recommended Specifications to Install an Elexsys
23
TM Eeds 30
23
Servicing, Storage and Transportation
24
Important Safety Instructions
24
Storage and Transportation
24
Installation Procedures
25
Figure 5: Installation Procedures
25
Installation Environment
26
Figure 6: Elexsys Rack Mounting Bolts
26
Table 3: Environmental Parameters
26
Installation Specifications
27
Figure 7: Illustration of Mounting Clearance (in MM) and Ventilation Requirement (Arrows Indicate Air-Flow Direction)
27
Connections
28
Table 4: Eeds Installation Specification
28
Table 5: Nuts, Bolts and Tightening Torque
28
Figure 8: Eeds Front Panel Connection Layout
29
Table 6: List of Connection Ports
29
Connections to Battery Energy System (BES)
30
Figure 9: Amphenol Surlock Connectors
30
Detachable Parts
31
Figure 10: AC and DC Terminal Safety Cover
31
Circuit Protection
32
Figure 11: Circuit Breaker Safety Cover
32
Earthing
33
Communications Ports
33
Figure 12: Earth Post Components
33
Figure 13: RJ45 Connector
34
Table 7: RJ45 Cat5 Pinout Diagram
34
Table 8: DRED RJ45 Socket Assignment
34
Auxiliary Power Connection
35
Earth Fault Alarm
35
Commissioning and Maintenance
36
Start Procedure
36
Table 9: Eeds Commissioning Tests
36
Table 10: Battery Commissioning Tests
36
Shutdown Procedure
37
Emergency Shutdown Procedure
37
Maintenance
38
Eeds Configuration
38
Grid Response Mode
38
Figure 14. Demand Response Mode
39
Power Quality Response Mode
40
Volt-Watt Response Mode (Default)
40
Figure 15. Power Quality Response Mode
40
Figure 16. Characteristic Curve of Eeds Power Exporting to Grid under Volt-Watt Mode
41
Figure 17. Characteristic Curve of Eeds Power Importing from Grid under Volt-Watt Mode
41
Volt-Var Response Mode
42
Voltage Balance Mode
42
Figure 18. Characteristic Curve of Eeds under Volt-Var Mode
42
Fixed Power Factor Mode
43
Fixed Reactive Power Mode
43
Battery Operating Mode
43
Figure 19. Characteristic Curve under Fixed Reactive Power Mode
43
Figure 20. Batter Operating Mode Flow Chart
45
Grid Protection Function
46
Voltage
46
Current
46
Frequency
46
Gradient of Power Rate
46
Connection and Reconnection
46
Anti-Islanding Protection
47
Active Anti-Islanding Protection
47
Passive Anti-Islanding Protection
47
Eeds Monitoring
47
Configuration Software GUI
48
Start Procedure
48
Figure 21: GUI Labelled Home Page
49
Figure 22: Setup Tab
49
Table 11: Operation Modes
50
Modbus Tab
51
Figure 23. Software GUI under Debugging Mode
51
Table 12: Modbus Register Map
52
Appendix
55
Mechanical Drawings
55
Figure 24. Front Panel
55
Figure 25. Side Panel
55
Figure 26. Back Panel
56
Demonstration of Eeds Operations
57
Case I - Battery Charging
57
Figure 27. Demonstration of Battery Charging at >= 99 % Status of Charge (SOC)
57
Table 13. Parameters Configure for Battery Charging and Discharging
57
Case II - Fixed Power Factor Mode
58
Case III - Over-Voltage Protection
58
Figure 28. Demonstration of Fixed Power Factor Mode at PF = 0.8
58
Case IV - Under-Frequency Protection
59
Figure 29. Demonstration of Over-Voltage Protection
59
Figure 30. Demonstration of Under-Frequency Protection
59
Advertisement
Advertisement
Related Products
eleXsys Categories
Power Inductor
More eleXsys Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL