Manuals and User Guides for Ebtron Advantage II Hybrid Series. We have
1
Ebtron Advantage II Hybrid Series manual available for free PDF download: Installation, Operation And Maintenance Manual
Ebtron Advantage II Hybrid Series Installation, Operation And Maintenance Manual (36 pages)
“Plug & Play” Transmitters
Brand:
Ebtron
| Category:
Transmitter
| Size: 0 MB
Table of Contents
Table of Contents
3
Overview
5
Specifications
5
Advanced Technology
5
Htx104 TRANSMITTER FEATURES
6
ORDERING GUIDE for Htx104 TRANSMITTER
6
Htx104 TRANSMITTER INSTALLATION
7
Mechanical Dimensions
7
Power Transformer Selection
8
Connecting Power to the Transmitter
8
Connecting Sensor Probes to the Transmitter
9
HTA104 Analog Transmitter Set up
10
HTA104 Analog Output Wiring
11
HTA104 Alarm Output Features
11
HTA104 Alarm Output and Hysteresis
11
HTA104 - Analog Output Signal Selection, 0-5VDC / 0-10VDC / 4-20Ma
11
HTA104 Output Scaling
11
Converting the Analog Output Signal from FPM to CFM (MPS to LPS for si Units Scaling)
11
Sending a Test Output Signal to the Host Control System
12
HTN104 RS-485 Transmitter Set up
13
Network Cable Specifications
13
HTN104 RS-485 Output Network Connections
13
Connecting to an Isolated RS-485 Network
14
Connecting to a Non-Isolated RS-485 Network
14
HTN104 Setting Network Options
14
HTN104 Setting the Network Protocol
14
HTN104 Setting the Transmitter Address
14
HTN104 Setting the Transmitter Termination
14
Modbus RTU
16
Htx104 TRANSMITTER START up
17
Transmitter Initialization
17
Changing the System of Units
18
Htx104 LCD Display Notifications
18
Last LCD Character Shown in Lower Case (Probe Malfunction)
18
All LCD Characters Shown in Lower Case(Field Cal Wizard Engaged)
18
LCD Blinks ** LOW ALARM **, ** HIGH ALARM ** or ** TRBL ALARM
18
LCD Display When Using HE1 ERV Probes
19
Htx104 Factory Default Settings
19
Factory Defaults for HP1 (-P), HF1 (-F), HB1 (-B), HT1 (-T) and HE1 (-E) Sensor Probes
19
Transmitter Calibration
20
Changing Factory Default Settings
20
Setup Menu Options
20
Changing the LCD Display from Velocity FPM to Volumetric Flow CFM (MPS to LPS for si Units)
20
Locking the Configuration Settings
20
Viewing Sensor Data
27
Local Sensor Data Display
27
Sensor Data over RS-485 Bacnet® Network
27
Connector Diagram
28
Field Adjustments
29
Adjusting the Low Limit Cutoff
29
Adjusting the Digital Output Filter
29
Field Calibration Wizard - Adjustment of Factory Calibration
29
Overview of the Field Calibration Wizard
29
Engaging and Using the Field Calibration Wizard
30
Manual Adjustment of Factory Offset/Gain Calibration
31
Procedure for 1 Point Field Adjustment
31
Procedure for 2 Point Field Adjustment
31
Maintenance
32
Standard Limited Parts Warranty
32
General Troubleshooting (All Htx104 Systems)
33
HTA104 - Analog Transmitter Troubleshooting
34
HTN104 - RS485 Transmitter Troubleshooting
34
Appendix A - Hta104 Wiring Diagram
35
Appendix B - Htn104 Wiring Diagram
35
Advertisement
Advertisement
Related Products
Ebtron Advantage III Gold Series
Ebtron Advantage Gold Series
Ebtron Advantage IV Series
Ebtron Advantage III GTM116-B
Ebtron Advantage Silver ST 102 Series
Ebtron Advantage Silver STA102-B
Ebtron Advantage Silver STA102-P
Ebtron Advantage Silver STA102-T
Ebtron GT 116 Series
Ebtron GTA116-B
Ebtron Categories
Measuring Instruments
Transmitter
Handhelds
Controller